manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Alarmtech
  6. •
  7. Security Sensor
  8. •
  9. Alarmtech MC 346 User manual

Alarmtech MC 346 User manual

Other Alarmtech Security Sensor manuals

Alarmtech GD 375 Instruction Manual

Alarmtech

Alarmtech GD 375 Instruction Manual

Alarmtech MC 470 User manual

Alarmtech

Alarmtech MC 470 User manual

Alarmtech CD 400 User manual

Alarmtech

Alarmtech CD 400 User manual

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech MC 140 User manual

Alarmtech

Alarmtech MC 140 User manual

Alarmtech AD 800-AM Manual

Alarmtech

Alarmtech AD 800-AM Manual

Alarmtech AD 800 Manual

Alarmtech

Alarmtech AD 800 Manual

Alarmtech GD 335 User manual

Alarmtech

Alarmtech GD 335 User manual

Alarmtech GD 370 User guide

Alarmtech

Alarmtech GD 370 User guide

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech CD 470-I User manual

Alarmtech

Alarmtech CD 470-I User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech MC 746-E User manual

Alarmtech

Alarmtech MC 746-E User manual

Alarmtech AD 700 User manual

Alarmtech

Alarmtech AD 700 User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech MC 340 2x4,7k User manual

Alarmtech

Alarmtech MC 340 2x4,7k User manual

Alarmtech MC 740-E-M14 User manual

Alarmtech

Alarmtech MC 740-E-M14 User manual

Alarmtech MC 472 User manual

Alarmtech

Alarmtech MC 472 User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MC 346 Instruction Manual 4-MC346-01
© 2018 Alarmtech Rev. MC346_2046en Page 1of 2
Detectors
Magnetic Contact
Recessed mounting
Instruction Manual MC 346
DESCRIPTION
MC 346 is a versatile magnetic contact used in both alarm
and security access control systems for protection of doors,
gates and windows against unauthorized opening. A wide
range of accessories enables the contact to be recessed- or
surface-mounted on a variety of surfaces, including
ferromagnetic materials.
MOUNTING INSTRUCTIONS
Contact and magnet should be installed axially,
corresponding to each other.
Catch-bolts on the housing enable direct installation in
ф8 mm holes in wood.
Appropriate accessory must be used for installation in
ferromagnetic environment.
CIRCUIT DIAGRAM
OPERATING PRINCIPLE
MC 346 magnetic contact has two parts: the contact part
with a reed switch and the magnet part. In its neutral
position the reed switch remains closed under the force of
the magnetic field. Opening the monitored object increases
the distance between the reed switch and the magnet. This
causes a change in position of the reed switch and as a result
–a path of the signal.
Magnetic contacts should not be installed in the vicinity of
strong magnetic fields.
TECHNICAL DATA
Working environment
Wood
Steel
Make distance
typ. 15 mm ± 40%
Not recommended
Break distance
typ. 17 mm ± 40%
Not recommended
Contact type
form C, SPDT
Switching voltage max.
48 V DC/AC
Switching current max.
250 mA DC / 180mA AC
Contact rating max.
5 W
Environmental class (EN50130-5:2011)
IIIA
Cable
ф 3,6 mm, 5x0,182 mm2
Operating temperature range
-40°C to +70°C
Operating humidity range
max. 95% r. h.
Housing material
plastic ABS
Dimensions:
Contact part
ф 9 x 36 mm
Magnet part
ф 9 x 25,5 mm
Security grade (EN50131-2-6:2008)
2
MC 346 Instruction Manual 4-MC346-01
© 2018 Alarmtech Rev. MC346_2046en Page 2of 2
INSTALLATION
Contact and magnet should be aligned axially in the frames
and leaves of the monitored objects (windows, doors etc.).
Offset will reduce the working distances. The contact should
be mounted in the stationary part of the monitored object
(ex. door frame) and the magnet in the movable part (ex.
door leaf). Before mounting, holes must be drilled. Catch-
bolts on the housing enable direct installation in ф8 mm
holes in wood.
For sites where it is impossible to mount the contact
directly, a variety of accessories is available.
Accessories with a strong magnet provide a bigger working
distance for more demanding applications and maintain the
parameters of the magnetic contact when mounted in
ferromagnetic environment.
Accessories for surface mounted applications provide
installation solutions for sites where recessed mounting is
not suitable.
The working distances of the magnetic contact will be
decreased in the proximity of ferromagnetic surfaces. The
closer the contact/magnet is installed to the ferromagnetic
surface, the lower the working distances
Only non-ferromagnetic screws may be used when mounting
the contact using accessories.
After the installation, use an ohmmeter to check the
electrical connections and test the function of the magnetic
contact.
Please note:
Applying excessive force to the housing of the contact may
damage the glass body of the reed switches inside.
Applying excessive force to the magnet can have a negative
impact on the magnetic field.