MC 346 Instruction Manual 4-MC346-01
© 2018 Alarmtech Rev. MC346_2046en Page 2of 2
INSTALLATION
Contact and magnet should be aligned axially in the frames
and leaves of the monitored objects (windows, doors etc.).
Offset will reduce the working distances. The contact should
be mounted in the stationary part of the monitored object
(ex. door frame) and the magnet in the movable part (ex.
door leaf). Before mounting, holes must be drilled. Catch-
bolts on the housing enable direct installation in ф8 mm
holes in wood.
For sites where it is impossible to mount the contact
directly, a variety of accessories is available.
Accessories with a strong magnet provide a bigger working
distance for more demanding applications and maintain the
parameters of the magnetic contact when mounted in
ferromagnetic environment.
Accessories for surface mounted applications provide
installation solutions for sites where recessed mounting is
not suitable.
The working distances of the magnetic contact will be
decreased in the proximity of ferromagnetic surfaces. The
closer the contact/magnet is installed to the ferromagnetic
surface, the lower the working distances
Only non-ferromagnetic screws may be used when mounting
the contact using accessories.
After the installation, use an ohmmeter to check the
electrical connections and test the function of the magnetic
contact.
Please note:
Applying excessive force to the housing of the contact may
damage the glass body of the reed switches inside.
Applying excessive force to the magnet can have a negative
impact on the magnetic field.