Installing and removing a fan tray /
!Follow these guidelines when you install or remove a fan tray:
在安装/拆卸风扇模块时,请注意如下事项:
Make sure the airflow direction of the fan tray is as required by the installation site.
请确认风扇模块气流方向和安装环境的通风要求一致。
The switch comes with the fan tray slots empty. Before powering on the switch, install a fan tray in
each fan tray slot and make sure the installed fan trays are the same model.
交换机出厂时风扇插槽均为空,为保证设备的正常散热,用户必须满配相同型号的风扇模块,
否则禁止交换机上电运行。
If more than one fan tray fails during switch operation, do not remove these fan trays simultaneously.
Replace one fan tray at a time and the replacement of each fan tray cannot take more than three
minutes.
在交换机运行过程中,如果有多个风扇模块出现故障,在更换风扇模块过程中禁止同时拔出多个风
扇模块,应按照拔出一个立即更换一个的方式进行,且单个风扇模块的更换时间不能超过3分钟。
Mounting brackets near the port side
挂耳安装在靠近端口侧
3
Mount the switch in the rack (two options) 安装交换机到机柜(二选一)
Mounting brackets near the power module side
挂耳安装在靠近电源侧
3
4
4
4
4
Connect the other end of the grounding cable to
the grounding point on the rack
接地线另一端连接到机柜接地点
LSPM1FANSA LSPM1FANSB
Airflow direction of the switch
Make sure the air inlet and outlet vents are not blocked and the installation site has a good
ventilation system.
请确保交换机的进、出风孔不被遮挡,并将交换机安装在具有良好通风散热系统的环境中。
Y ou can provide airflow for the switch from the port side to the power module side or from the
power module side to the port side by installing different fan trays.
通过配置不同的风扇模块,可提供“端口侧到电源侧”和“电源侧到端口侧”两种气流方向,满足
不同环境下的散热要求。
The LSPM1FANSA blow air from the power module side to the port side. The LSPM1FANSB draw
air from the port side to the power module side.LSPM1FANSA为吹风风扇,风向为电源侧进风,端
口侧出风;LSPM1FANSB为抽风风扇,风向为端口侧进风,电源侧出风。
1
1
2
Remove a fan tray 拆卸风扇模块Install a fan tray 安装风扇模块
Installing and removing a power module /
Available power modules vary by device model, but the installation and removal prOcedures are
The same. The following uses the PSR250-12A as an example. To remove a power module,
first remove the power cord.
各款交换机支持的电源模块不同,但安装与拆卸方式相似,此处以安装PSR250-12A电源模块为例示意。
For power modules available for the switch, see H3C S6860 Switch Series Installation Guide.
各款交换机支持的电源模块型号,请参见《 H3C S6860系列以太网交换机 安装指导》。
Make sure the airflow direction of the power module is as required by the installation site.
Do not install power modules with different airflow directions on the same switch.
请确认电源模块气流方向和安装环境的通风要求一致。不同气流方向的电源模块不要混插在同一台交
换机上。
!
Install and remove a power module
1
Install a power module 安装电源 Remove a power module拆卸电源
5
To remove a DC power cord, you must first use a
screwdriver to loosen the captive screws on the
power cord connector.For a PSR450-12D power
module, use a flat-head screwdriver to loosen the
screws on the connector, and then remove the
power cord connector from the power module.
需要注意的是,在拆除PSR450-12D电源模块时,
要先拆除直流电源插头。PSR450-12D电源模块需
要先使用一字螺丝刀逆时针拧下直流电源线插头两
侧自带的螺钉,然后将插头向外拔出。
1
2
2
1
Connect the other end of the grounding cable to
the grounding point on the rack
接地线另一端连接到机柜接地点