manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. hager
  6. •
  7. Timer
  8. •
  9. hager EG 270 User manual

hager EG 270 User manual

Other hager Timer manuals

hager EH 010 User manual

hager

hager EH 010 User manual

hager EG110 User manual

hager

hager EG110 User manual

hager EH710 User manual

hager

hager EH710 User manual

hager EGN200AU User manual

hager

hager EGN200AU User manual

hager EH716 User manual

hager

hager EH716 User manual

hager EG010 User manual

hager

hager EG010 User manual

hager EH010 User manual

hager

hager EH010 User manual

hager EG270 User manual

hager

hager EG270 User manual

hager EGN200 User manual

hager

hager EGN200 User manual

hager EG 172 Installation instructions

hager

hager EG 172 Installation instructions

hager EH 110 User manual

hager

hager EH 110 User manual

hager EH 110 User manual

hager

hager EH 110 User manual

hager EGN100 User manual

hager

hager EGN100 User manual

hager EH 266 User manual

hager

hager EH 266 User manual

hager EG002 User manual

hager

hager EG002 User manual

hager EG103E User manual

hager

hager EG103E User manual

hager EG203E User manual

hager

hager EG203E User manual

hager EH712 User manual

hager

hager EH712 User manual

hager EG470 User manual

hager

hager EG470 User manual

hager EG 100 User manual

hager

hager EG 100 User manual

hager EGN100AU User manual

hager

hager EGN100AU User manual

hager EG210 User manual

hager

hager EG210 User manual

hager EH 712 User manual

hager

hager EH 712 User manual

hager EH010 User manual

hager

hager EH010 User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

res
7
6
on
off
5
4
3
2
1
ON
ON
OFF OFF
enter
A
B
auto
manu
EG 270
Working principle :
The EG 270 is a time switch for the
automatic control of electrical loads.
It is fully programmable with a maximum
of 20 program steps to be divided bet-
ween the two channels. Each program
step can be applied to one or several
days, maximising the use of each memo-
ry location.
The front cover is sealable preventing
unauthorised access after completion of
programming.
Warning : at the beginning of use, please
reset the device in order to clear the
memory before programming.
This is achieved by using a pen to push
the reset button.
Presentation :
Display :
➀time
➁circuit status of channel A (ON or OFF)
➂circuit status of channel B (ON or OFF)
➃day of the week
(1 = Monday, 2 = Tuesday ....)
Buttons :
➄Mode selector : to select one of the
following modes :
time setting
Aprogramming channel A
Bprogramming channel B
auto running mode
manu manual override
➅“1” to “7” : selection of the days
➆“on/off” : chooses whether the circuit
is on or off
➇“+” and “-” : changes settings
➈“enter” : to confirm
➉“reset”
Time and day setting :
1. Move mode selector to
2. Select with key “1”to “7”, the actual day
(1=Monday, 2 = Tuesday .)
3. Input time with buttons “+”and “-”.
Important :
The clock starts when exiting the time setting mode.
Programming channel A :
1. Move mode selector to “A”.
2. Select with keys “1”to “7”the day(s) assigned
to this program step. An arrow appears
above each day concerned.
3. Input switching time with buttons “+”and “-”.
4. Input the type of switching with button “on/off”
(for the first action ON is automatically proposed).
5. Enter this program step with button “enter”.
Program additional time settings by repeating
steps 2 to 5.
Important :
To activate the program, move mode selector to
“auto”.
Programming channel B :
Move mode selector to “B”.
Same way of programming as channel A.
Important :
To active the program, move mode selector to “auto”.
Running Auto mode
This mode is the current displaying mode.
It does not allow any modification.
Move mode selector to “auto”.
Display of the time, the day and the state of the two
channels.
To check your program on channel A
or B :
1. Move mode selector to “A”or “B”.
2. Press the “enter”key repeatedly to display the
different program steps (switching time, days of
the week and state of the channel ON or OFF).
To override the output :
Important : the override must be identical on the
two channels (channels A and B “ON”“ON”or
channels A and B “OFF”“OFF”).
Permanent override :
1. Move mode selector to “manu”.
2. Select the state of the outputs with key “on/off”.
To switch back to automatic mode, move mode
selector to “auto”.
1234567
1
2
4
3
5
6
78 9
10
enter
reset
on
off
A
B
auto
manu
ON ON
1234567
enter
reset
on
off
A
B
auto
manu
To modify or delete a program step on
channel A or B :
1. Move mode selector to “A”or “B”.
2. Press “enter”repeatedly and select the program
step to modify or to delete.
3. Modify :
- switching time with keys “+”or “-”
- days assigned with keys “1”to “7”.
(an arrow flashes above all days assigned,
press once to add a day, press twice to cancel).
- state of the channel with key “on/off”.
To delete a program step, press keys “1”to “7”in
order to cancel all days assigned.
4. Confirm with the “enter”key.
2 channels time switch -
weekly cycle
1234567
enter
reset
on
off
A
B
auto
manu
ON ON
1234567
enter
reset
on
off
ON ON
A
B
auto
manu
1234567
enter
reset
on
off
A
B
auto
manu
ON ON
User instruction GB
345621
L
N
EG 270
987 10 11 12
A
B
Technical specifications :
Electrical characteristics :
- supply voltage : 230V +10/-15% 50Hz
- outputs : 2 changeover contact
µ 16A - 250V AC1.
µ 3A - 250V cos = 0,6
1000 W incandescent lighting
- power consumption : 1 VA
- protection degree : IP20
- insulation class : II
Functional characteristics :
- accuracy : ± 1sec. / day at 20 °C
- operating reserve : lithium battery,
total of three years.
Environment :
Operating temperature : -10 to +50 °C
Storage temperature : -10 to +50 °C
Connection tunnel terminals :
flexible : 0,5 to 2.5 mm2
rigid : 0,5 to 4 mm2
Dimensions : 3 modules (3x17,5mm)
Electrical connections :
1. Move mode selector to “manu”.
2. Select the state of the outputs with key “on/off”.
3. Input with key “+”and “-”the override duration :
from 1 to 23 hours by steps of 1 hour.
Then from 1 to 27 days by steps of 1 day.
4. Move mode selector to “auto”.
The state indication is flashing. This means a timed
override. Return to the initial program after the
duration.
To reset the time switch :
Press “reset“to clear the program.
1. Move mode selector to “manu”.
2. Press key “-”or “+”until display -h.
3. Move mode selector to “auto”to switch back to
automatic mode.
Timed override :
To cancel the timed override :
1234567
enter
reset
on
off
A
B
auto
manu
ON ON
1234567
enter
reset
on
off
A
B
auto
manu
ON ON
A warranty period of 24 months is offered on hager products,
from date of manufacture, relating to any material of manu-
facturing defect. If any product is found to be defective it must
be returned via the installer and supplier (wholesaler). The
warranty is withdrawn if :
- after inspection by hager quality control dept the device is
found to have been installed in a manner which is contrary to
IEE wiring regulations and accepted practice within the industry
at the time of installation.
- the procedure for the return of goods has not been followed.
Explanation of defect must be included when returning
goods.
Warranty GB
6E 6128.b