Operation
Air Flow Direction Adjustment
Base Operation
Remote controller
Emergency operation and test operation
Operation
Mode
Remote
Controller Note
In DRY mode , when room temperature becomes lower
than temp.setting+2oC, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool operation according to room
temperature. When FAN is set to AUTO the air conditioner
automatically adjusts the fan speed according to room
temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
below 16oC, do not use it in the normal operation.
Test operation:
Use this switch in the test operation when the room
temperature is
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds.After
you hear the "Pi" sound twice, release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
DRY
COOL
AUTO
FAN
Emergency Operation:
Use this operation only when the remote
controller is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which
the start of this operation.
In this operation, the system automatically
selects the operation modes,cooling or fan
or heat, according to the room temperature.
It is not possible to operate in dry mode.
Room
temperature Operation
mode Designated
temperature Timer
mode Air flow
ABOVE 23OCCOOLING 26OCNO AUTOMATIC
(cooling only uint)
Room temperature Operation
mode Designated
temperature Timer
mode Air flow
BELOW 23OCFAN 26OCNO AUTOMATIC
means
Pi
Pi Pi
1
3
2
2
Press FAN button
Remote controller:
Press button
Every time the button is pressed,
temp.setting increase 1 C,if kept
o
depressed, it will increase rapidly
Every time the button is pressed,
temp.setting decrease 1 C,if kept
depressed, it will decrease rapidly
Select a desired temperature.
3.Fan function
2.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to
room temperature.
1.Unit start
Press ON/OFF on the remote controller, unit starts.
/
changes as follows:
LOW MED HI AUTO
Display
circulated
For each press button fan speed
o
1.Status display of air flow
COOL/DRY:
Initial state
Press button to enter additional options, when cycle
display to , will flash.And then press enter to
up and down air flow function.
Press button. For each press,changes as follows:
Remote controller:
When restart after remote turning off, the remote controller
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY mode,otherwise,
condensate water might occur.
air outlet if all vertical louvers are adjusted to left or right.
will automatically return to the previous set swing position.
Note:
Move the vertical blade by a knob on air conditioner to adjust
left and right direction referring to Fig.
2.Left and right air flow adjustment (manual)