1
2
3
4
This switch controls the preset indoor
temperature to make the air conditioner start or
stop automatically, so as to reduce power
consumption and operate the system both
comfortably and economically.
Operate the switch as follows: Temp.
decreases as the switch is turned form “1” to
“9”. Temp. increases as the switch is turned
from “9” to “1”.
“Test run” mode.
(For model HW-09CV03, HW-12CV03,
HW-09CVA03, HW-12CVA03 only)
When switch set to this position, air-con will
run continuously regardless of temp. setting.
Don’t use test run for normal operation.
The compressor stops running when the set
temperature is reached but the fan continues to
operate to keep an even indoor temperature.
Always turn off the air conditioner and the main power supply before clean the unit.
Switch off the power supply if the unit is not going to be used for a long period of time.
CAUTION
Note:
In cooling mode, after you turn
thermostat switch counter-clockwise,do
not turn it back until at least 3 minutes
have elapsed.Otherwise, the fuse may
blow due to overload.
Do not exceed the selection range.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor FAN
mode,otherwise , condensate water might occur.
Don't move the vertical flap with hand in order to avoid the vertical flap abnormal, using the
AUTO SWING switch to adjust the move of vertical flap.
Cleaning of the
air filter
After unit stops, don't restart it
until 3 min. have elapsed.
Don't be exposed to cold air for
a long time.
Avoid opening doors and windows
unless necessary.
Use curtain or blind
Direct sunlight may reduce cooling
effect, always use window curtain.
Keep heat source away from
air conditioner.
Set temp . a little bit higher
before going to bed.
OK! Enjoy a
3-min nap
Proper
temperature
HW-09CV03 HW-09CVA03
HW-12CV03 HW-12CVA03
HW-18CV03 HW-18CVA03
Please read this operation manual before using the air conditioner
Please keep it attentively
0010556533
OPERATION MANUAL
Applicable ambient temperature range:
OPERATION CONDITIONS
Cooling Indoor Outdoor
Max.Temperture:
Min.Temperture:
D.B D.B
W.B W.B
32 C
o
23 C
o
18 C
o
14 C
o
43 C
o
26 C
o
18 C
o
/
ROOM AIR CONDITIONER
CONTENTS
Safety precautions...................1
Air conditioner operation..........2
Care and Maintenance ............4
Air conditioner installation........5
Troubleshooting.......................7
D.B :Dry Bulb Temperature
W.B :Wet Bulb Temperature
AIR CONDITIONER OPERATION
2CARE AND MAINTENANCE
3
SAFETY PRECAUTION
1
Operation Guide
It is advisable to clean air filter every two weeks for
longer operation.
(You will find how to clean the filter on page 2 .)
Baby has
gone sleep,
better to adjust
suitable temp.
Don't hang clothes in the vicinity
of air inlet. This will decrease
cooling effect and cause abnormal
operation.
Temperature should be set properly
when there are infant,child, the
aged or disabled in the room.
Before operating mode
selection switch, check that if
the air inlet or outlet have been
blocked.
1.Do not install, remove and reinstall the unit yourself. Improper installation may cause leakage, electric
shock or fire. Please engage an authorized dealer or specialist for the installation work.
2.The room air conditioner must be earthed.
3.Do not touch or operate with wet hands.
4.Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the power
plug.
5.Do not insert sticks, fingers or other objects into the unit.
6.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person.
7.After installation, the power plug should be easily reached.
8.The wiring method should be in line with the local wiring standard.
CAUTION
Air filter cleaning
1
Notes
2
Auto swing switch
1
Thermostat switch
2
Mode selection switch
3
Operation panel
COOL
1
3
6
9
Test
run
LO
cool
HI
cool
HI
fan
LO
fan
OFF
Wait 3 minutes before restarting.
Mode selection
OFF ON
Auto swing Temp. setting
HW-09CV03 HW-09CVA03
HW-12CV03 HW-12CVA03
HW-18CV03 HW-18CVA03
Mode selection
LOW
COOL
HIGH
COOL
HIGH
FAN
LOW
FAN
OFF
OFF ON
Auto swing Temp. setting
MIN
COOL
MAX
COOL
1
2
3
4
56
7
8
9
10
WAIT THREE MINUTES BEFORE RESTARTING
When the swith is set to “ON”, vertical louver
will swing from side to side, delivering gentle
air thus making you feel very comfortable.
When it is set to “OFF”, vertical louver will
stop at position.
Mode switch controls the fan motor speed.
Cooling speed or fan speed.
When set to “HI fan”, fan motor runs at high
speed to blow out strong air.
When set to “LO fan”, fan motor runs at low
speed to blow out gentle air.
When set to “HI cool”, air-con will start
cooling at high speed, blowing out strong
air.
When set to “LO cool”, air-con will start
cooling at low speed, blowing out gentle air.
When set to “OFF”, air conditioner stops
running.
When mode selection switch is shifted to “HI
fan” or “LO fan”, air-con will only blow out air
without cooling.While the air conditioner
running, its mode selection shouldn’t be shifted
frequently between “HI fan” and “HI cool”, “LO
fan” and “LO cool”.
HINTS
HINTS
Machine body
Take out the air filter
Clean the filter
When dirt accumulates on air filter, air
circulation will be blocked, which causes
poor cooling. It is advisable to clean air
filter every two weeks for longer operation.
1.Loose the air inlet by pushing
“PUSH” at both edges as
shown.
2.Open the air inlet.
1.Gently flap the dirt off the air filter.
2.Carefully wash air filter in warm water(below 40°C).To
obtain better cleaning effect,soap water or neutral
detergent may be used.
3.Flush air filter carefully with clean water after removing
dirt.Let it dry completely.
PART INDENTIFICATION
Airflow Direction Vane
Air filter cleaning
2Airflow Direction
3
Do not circumgyrate the
front panel any more than
90°to the unit or damage
to the tabs may occur.
CAUTION
Before cleaning, turn off
the power.
Front panel
Air inlet
(indoor side)
Air outlet
(indoor side)
Air inlet
(outdoor side)
Air filter (inside)
Machine body
3.Remove the air filter.
Installation of filter
1.Replacing the air filter.
2.Push the air inlet marked with “PUSH” until you hear a
click.
OPENCLOSE
The ventilation lever must be
CLOSE position in order to
maintain the best cooling
conditions. When fresh air is
necessary in the room, set the
ventilation lever to the OPEN
position. The damper is
opened and room air is
exhausted.
(For model HW-18CV03
HW-18CVA03 only)
Ventilation
1
The horizontal air direction is
adjusted by setting the
AUTO SWING switch to the
ON position.
The Vertical Airflow Direction
Vane is manually controlled
by positioning the vane to
discharge the air upward,
downward or straight out.
PUSH
PUSH
Air filter(inside)
COOL
1
3
6
9
Test
run
LO
cool
HI
cool
HI
fan
LO
fan
OFF
Wait3 minutes before restarting.
Modeselection
OFF ON
Autoswing Temp.setting