WH00X26332
Part Install Instructions
Overview – Procedure for programming new control boards
when all LED’s are flashing.
WH18X26217, WH18X26234, WH18X26794, WH18X26795,
WH18X27754 And WH18X26796 Washer Control Boards
!IMPORTANT SAFETY NOTICE
The information in this part instruction is intended for use by
individuals possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt to repair a
major appliance may result in personal injury and property damage.
The manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any liability in
connection with its use.
!WARNING
To avoid personal injury, disconnect power before servicing this
appliance. If electrical power is required for diagnosis or test
purposes, disconnect the power immediately after performing the
necessary checks. RECONNECT ALL GROUNDING DEVICES If
grounding wires, screws, straps, clips, nuts, or washers used to
complete a path to ground are removed for service, they must be
returned to their original position and properly fastened.
Parts Included:
• Control Board • Instruction Sheet
HTW200**K0 / K1
MTW200**K0
GTW685**L0 and higher
GTW220**K0 / K1 / K2
HTW240**K0 / K1
HTW200**K3 and higher
GTW330**K0 / K1
GTW750**L0 and higher
HTW200**K2
GTW460**J0 / J2
GTW680**J5 and higher
GTW680**L0 and higher
GTW330**K3 and higher
GTW680**J0 /J1 /J2
GTW220**K3
HTW240**K2
GTW485**J0 / J1
Model Number ID ID ID
Model Number Model Number
GTW330**K2
GTW460**J1 / J3 / J4 / J5 / J6
GTW460**J7
GTW220**K4 and higher
HTW240**K3 and higher
GTW490**J0 / J1
12
02
05
01
07
00
10
11
06
09
08 GTW485**J2 / J3 14
GTW490**J2 and higher
GTW460**J8 and higher
GTW680**J3 / J4 03
04
GTW485**J4 and higher
1. Press Start button. LED’s will stop flashing and the personality ID can be selected.
Models with seven segment display will show the personality ID number in the display.
Models without seven segment display will show the personality ID number on the
status LED’s using binary coding. (See binary chart on reverse side)
2. Press and release the Start button to increment to the next personality ID number. The first
personality may be 0. All cycle status LED’s will be off. When the end of the ID list is reached
the control will wrap around to the beginning of the personality ID number list.
3. When the correct personality ID number is in the display or if the correct status LED’s are lit
for the personality ID number needed, press and hold the Start button for three seconds. This
will save the personality ID number and the control; will go to an idle state.
If an error is made in programming the control or if the LED’s are not flashing, enter Field Service
Mode as shown on the back of these instructions and use service mode test 17 to correct.
13
GTW755**M0 and higher
FIELD SERVICE MODE ENTRY
From an idle state only (all LEDs off), press
and hold Start button while rotating the cycle
selection knob 180 degrees (7 clicks) and
then release the Start button.
• Once service mode is entered all LEDs will
be flashing.
– On 7-segment display models: (0) will be
displayed for Test (0).
– On models without a 7-segment display: All
of the status LEDs above the cycle knob will
be lit.
• The cycle selection Knob is now used to
control the test selection menu.
– Rotating the knob clockwise will
increment the test numbers in the
display.
– Rotating the knob counter clockwise will
decrement the test number in the display.
– Models without 7-segment display: Will
display tests using the status lights above the
cycle knob in a binary format. (See Binary
Chart)
– Turning the knob to go to a different test will
terminate any current active state.
• Once the test number is selected, pressing Start
will begin the selected test.
Exit Field Service Mode
• Field service mode will time out after 30 minutes
if there is no user activity.
• Models without 7-segment display: Press and
hold the Start button for 3 seconds
• Models with a 7-segment display: Press Power
button
SERVICE MODE TEST 17-
Change Personality
Pressing Start will start the test. Press Start
button again and the next valid personality should
be displayed. Press and hold the Start button to
select the correct personality. The control will go to
an idle state. All LED’s off.
Note: Upon entering test 17 for models,
GTW220**K0, K1 and K2,
HTW240**K0 and K1, and also
HTW200**K3 and higher
the cycle status LED’s will not be lit for
personality 0.
Note: If the personality ID is already
set and you try to set the same
personality the control will NOT go to
an idle state. Ensure the correct
personality ID is being entered.
Personality Number in Binary Code
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14

This manual suits for next models

5

Other Haier Control Unit manuals

Haier YR-E16b User manual

Haier

Haier YR-E16b User manual

Haier GE WE04M10006 Configuration guide

Haier

Haier GE WE04M10006 Configuration guide

Haier GE WH18X28642 Configuration guide

Haier

Haier GE WH18X28642 Configuration guide

Haier GE WE04X27596 Configuration guide

Haier

Haier GE WE04X27596 Configuration guide

Haier GE WH22X29345 Configuration guide

Haier

Haier GE WH22X29345 Configuration guide

Haier YR-H71 User manual

Haier

Haier YR-H71 User manual

Haier GE WH22X29556 Configuration guide

Haier

Haier GE WH22X29556 Configuration guide

Popular Control Unit manuals by other brands

WEG SSW900-CETH-IP-N Installation, configuration and operations guide

WEG

WEG SSW900-CETH-IP-N Installation, configuration and operations guide

Danfoss PVEO installation guide

Danfoss

Danfoss PVEO installation guide

Greenheck KFCC Installation, operation and maintenance manual

Greenheck

Greenheck KFCC Installation, operation and maintenance manual

Grundfos CU 321 Installation and operating instructions

Grundfos

Grundfos CU 321 Installation and operating instructions

Vintage Air 46115-VUH manual

Vintage Air

Vintage Air 46115-VUH manual

Siemens 6SE7024-1EP85-0AA1 operating instructions

Siemens

Siemens 6SE7024-1EP85-0AA1 operating instructions

Ecolab MULTILINE 1000 Short operating instructions

Ecolab

Ecolab MULTILINE 1000 Short operating instructions

Overkiz Hattara DIN Rail PSU quick start guide

Overkiz

Overkiz Hattara DIN Rail PSU quick start guide

Meech 271 operating manual

Meech

Meech 271 operating manual

Allen-Bradley MicroLogix 1500 1764-MM1 installation instructions

Allen-Bradley

Allen-Bradley MicroLogix 1500 1764-MM1 installation instructions

VAT 110 Series Installation, operating,  & maintenance instructions

VAT

VAT 110 Series Installation, operating, & maintenance instructions

Honeywell 5496 Installation and operation guide

Honeywell

Honeywell 5496 Installation and operation guide

Fenwal 35-63 Series manual

Fenwal

Fenwal 35-63 Series manual

Siemens SIPROTEC PROFINET IO manual

Siemens

Siemens SIPROTEC PROFINET IO manual

Watts LFM114-2 manual

Watts

Watts LFM114-2 manual

Char-Broil 468990520 Product guide

Char-Broil

Char-Broil 468990520 Product guide

Discount Car Stereo iP2D-BKR Quick start installation guide

Discount Car Stereo

Discount Car Stereo iP2D-BKR Quick start installation guide

Samson 3510-1 Mounting and operating instructions

Samson

Samson 3510-1 Mounting and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.