Interface Display
Parts and Functions

2
On/O key.
Mode key: Press this key to execute mode switch.
Fan key: Press this key to adjust fan speed.
Up/Down key: Press this key to adjust temperature
in the main Interface and other parameter value
in other interface. And the key is also used for
function switching.
Time key: Press this key to set clock time / Timer
and malfunction parameter queried.
Menu key: Press this key to enter function
circulation. Also this key is used to conrm
changes.
Key
Parts and Functions
Clock display , parameter display
Timer ON/OFF
ROOM /SET temperature display
Icon

3
Parts and Functions
ROOM/SET humidity display
Error icon
Four-sided air deector display ( Only valid
for part of models)
Up/Down Swing
Left/Right Swing (Only valid for part of models)
Set icon
Auto mode
Cooling mode
Heating mode
Fan mode
Dry mode
Turbo: This icon will be displayed only when turbo
function is set.
Quiet: This icon will be displayed only when quiet
function is set.

4
Parts and Functions
Sleeping: This icon is displayed when sleeping is
set, and remaining time of sleeping is displayed by
Health : This icon will be displayed only when
health function is set.
HRV (Heat Reclaim Ventilation): This icon will be
displayed only when HRV function is set.
Energy Saving: This icon will be displayed only
when energy saving function is set
Static Pressure: This icon will be displayed only
when setting static pressure function.
Filter Cleaning
Child Lock: This icon will be displayed only when
child lock function is set.
Lock
Central
Motion Sensing (only valid for part of models)
Master: This icon will be displayed only when
controller is set as master controller.
Slave: This icon will be displayed only when
controller is set as slave controller.

5
Parts and Functions
(1) fan speed( only valid for part models)
Breeze Fan Speed
Low Fan Speed
Medium Fan
Speed
High Fan Speed
Super Fan Speed
Auto Fan Speed
(2) fan speed( only valid for part models)
Seven gear
Sixth gear
Fifth gear
Fourth gear
Third gear
Second gear
First gear
Auto

6
Operation
Basic function Method of operation
ON/OFF Press the key to switch on/o the
wired controller.
Mode control In the state of on, press the key
MODE to change mode.
Adjusting temperature In the state of on, press the key or
to adjust temperature.
Adjusting fan speed In the state of on, press the key FAN
to adjust fan speed.
Basic function description

7
Operation
Initialization
(1) The wired controller will display all the icons after be
powered on or reset, then it gets into the initializing process.
The controller will display in sequence as follows :
(the top-left corner) → → (the bottom-right corner)
→ (the top-left corner), the green LED (ON/OFF key)
ashes all the time until the initialization ends.
(2) If the wired controller can’t communicate with the indoor
unit PCB normally after powering on, the initialization will be
nished in 4 minutes, and then the communication malfunction
can be checked from the malfunction inquiry function.
Backlight time
(1) In the state of o , when the backlight is lit up, long press
TIME and keys for 5 seconds to set backlight time, the
parameter value is displayed in the upper left corner. Press
or key to switch parameter between 00(means backlight
always on)/15S/30S/60S and conrm by pressing the key
MENU.
(2) The backlight time is xed for 15 seconds when the
controller is turned o.

8
Operation
Note:
When controlling Fresh Air unit, the controller’s main interface
will not display and keys in normal state. If you need to
adjust the backlight time, please press MENU key to display
and keys. And then long press TIME and keys for 5
seconds to set backlight time.
Clock
(1) The controller uses 24-hour clock. The default is 12:00
when the wired controller is turned on for the rst time.
(2) When the backlight is on, long press TIME key for 5
seconds to enter clock setting function. At this time, the minute
of the time and icon are ashing in the upper left corner.
You can use or key to adjust the minute value, and long
press or key to speed up the adjustment. Then press
TIME key to switch to hour adjustment, and use or key to
adjust the hour value. Finally, you need to press MENU key to
conrm the changes and return to the main interface.
(3) In the process of time adjustment, if there is no operation
for 10 seconds or press MODE / FAN key, it will quit and
previous changes are invalid.
(4) Under timer or sleeping function, clock time can’t be
adjusted.

9
Operation
(1) Timer function includes Timer on, Timer o and Timer on/
o.
(2) Press TIME key to enter timer setting, then you can use
TIME key to switch parameters, the timer function circulation is
as follows:
(ON and the hour position are ashing) →
(ON and the minute position are ashing) →
(OFF and the hour position are ashing) →
(OFF and the minute position are ashing) →
(ON and the hour position are ashing) →
(ON and the minute position are ashing) →
(OFF and the hour position are ashing) →
(OFF and the minute position are ashing) →
the timer icon disappears (cancel timer function).
Timer

10
Operation
(3) When the hour or minute position is ashing, press or
key to adjust the parameter value, and long press or key
to speed up the adjustment. Then you need to press MENU
key to conrm the setting.
(4) The timer function will be canceled when you press TIME
key multiple times until the timer icon disappears.
Function circulation
Press MENU key (if it is the 4-way/Round-way Cassette
model, you need press MENU key for 5 seconds) to enter
function circulation, use or key to switch between
dierent functions.
The function circulation is as follows (functions that are not
valid for some models do not participate in the circulation,
please refer to the function description of the indoor unit):

11
Operation
(Humidity setting) → (Up/Down swing) →
(Left/Right swing) → (Turbo function) → (Indoor unit
quiet) → (Outdoor unit quiet) → (Sleeping) →
(Health) → (HRV) → (Energy saving) → (Static
pressure) → (Filter cleaning) → (Follow) →
(Evade) → (Perception) → 10 (10°C heating) → (Health
airow up) → (Health airow down) → CL (Self- cleaning).
When you select a function, the corresponding icon ashes,
then you can use MENU key to set/cancel function or enter the
corresponding function setting interface.
Humidity setting (only valid for part of models)
Press MENU key, you will enter function circulation, humidity
setting will be displayed rst. Then press MENU key to enter
setting interface, at this time, you can use or key to
adjust humidity parameter. The parameter adjustment range is
30%~70%. Enter into automatic control by pressing when
the humidity is 70% or pressing when the humidity is 30%,
and “AUto” character will be displayed in the upper left corner.
Adjustment accuracy is 5%. After adjustment, press MENU
key to exit the setting interface.

12
Operation
(1) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to the
Up/Down swing or Left/Right swing, then press MENU key
again to enter the setting of swing angle (only valid for part
of models). At this time you can use or key to adjust the
swing angle. After adjustment, press MENU key to exit the
setting.
(2) After adjustment, if there is no operation within 10 seconds
or press MODE / FAN key, it will quit swing setting interface
and previous changes are valid.
Note:
When the communication protocol which the wired controller
adopts is the second version, the up/down swing and left/right
swing, or only the up/down swing is alternative by dip switch
SW7. (When the communication protocol is the third or rst
version, SW7 is invalid.)
Swing

13
Operation
(1) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to
(health airow up) or (health airow down) function, then
press MENU key again to set the function. When the function
is successfully set, the corresponding icon will be displayed on
the main interface.
(2) Health airow up/down function cannot be set at the
same time. When the latter function is set, the former will be
automatically canceled.
(3) When health airow up/down function is set, if you adjust
the swing angle, the health airow up/down function will be
canceled.
Health airow up/down function (only valid for part of
models)

14
Operation
(1) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to
function, then press MENU key again, HRV function will
be turned on. If the function is turned on, icon will be
displayed in the main interface.
Heat Reclaim Ventilation
(1) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to
function, the sleeping time will display by the which
is on the top-left corner. Press TIME key to enter sleeping time
setting, use or key to adjust the sleeping time by 0.5h
once, the range of sleeping time is from 0.5h to 72h, press
MENU key to conrm.
(2) When the sleeping time is up, the controller will turn o.
(3) If the state of the sleeping function is on, when you switch
to the sleeping function in the function circulation, pressing
MENU key to turn it o.
(4) If controller is turned o when the sleeping function is
turned on, the sleeping function will be cancelled.
Sleeping

15
Operation
(1) If the current temperature is displayed in Celsius, adjust
temperature in each mode to 30°C(when energy saving
function is set currently, the parameter in heating mode will be
the highest limit value). Then press key for 15s to switch
to Fahrenheit, the interface will display 86°F (when energy
saving function is set, its highest limit value of Fahrenheit will
be displayed).
(2) If the current temperature is displayed in Fahrenheit, setting
temperature should be adjusted to 60°F in each mode(when
energy saving function is set currently, the parameter in
cooling/dry mode will be the lowest limit value). Then press
key for 15s to switch to Celsius, the interface will display 16°C
(when energy saving function is set, its lowest limit value of
Celsius will be displayed).
Switch between Fahrenheit and Celsius
(2) When the HRV function is turned on, if you want to turn it
o, please enter function circulation and switch to icon,
then press MENU key , and the function will be turned o.

16
Operation
(1) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to
function, then press MENU key again, energy saving function
will be turned on. If the function is turned on, icon will be
displayed in the main interface.
When the energy saving function is set, press MENU key to
enter function circulation and choose , then press MENU
key to exit energy saving function.
(2) If the energy saving function is turned on, the adjustment
of the setting temperature of the cooling/dry/heating mode will
be limited. The energy saving default parameters are 23°C (the
lowest temperature limit of cooling and dry mode) and 26°C (the
highest temperature limit of heating mode).
(3) The energy saving parameters can be changed.
①In cooling mode, set temperature to 30°C, long press FAN
key for 5 seconds to enter energy saving parameter of cooling/
dry mode setting, the parameter will be displayed in the top-left
corner. You can use or key to adjust parameter, and the
parameter adjustment range is from 16 to 30. After adjustment,
you need to press MENU key to conrm changes.
Energy saving

17
Operation
②In heating mode, set temperature to 16°C, long press FAN
key for 5 seconds to enter energy saving parameter of heating
mode setting, the parameter will be displayed in the top-left
corner. You can use or key to adjust parameter, and the
parameter adjustment range is from 16 to 30. After adjustment,
press MENU key to conrm changes.
When lter cleaning icon is displayed, the icon will display
in function circulation. Press MENU key to enter function
circulation, use or key to switch between dierent
functions. Switch to icon, press MENU key again to cancel
the display of icon .
Filter Cleaning
(1) Only in heating mode, this function is valid in function
circulation.
(2) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. When it
switches to the 10°C heating function, 10°C will ash in the
temperature display area. Press MENU key to conrm.
(3) In the state of the 10°C heating function, when you switch
to the 10°C heating function in the function circulation,
pressing MENU key to turn it o.
10°C heating function (only valid for part of models)

18
Operation
(4) In the state of 10°C heating function, if you change modes
or adjust temperature setpoint, you will exit the 10°C heating
function.
(1) For 4-way/Round-way Cassette, the icon and the
icon will be displayed in the main interface.
(2) Press MENU key to select the air deector to be set (By
pressing MENU key, you can switch between the air deector
1,2,3,4 as well as the simultaneous control.), and which air
deector ashing indicates that it is selected. When selecting
a certain air deector, you can use or key to adjust its
swing angle.
(3) After adjustment, you can press MODE / FAN / TIME key or
wait 10 seconds to exit the settings.
Four-sided air deector (only valid for part of models)

19
Operation
(1) Motion sensing function includes , and
(Follow): Swing direction follows people.
(Evade): Swing direction Evades people.
(Perception): If no one is perceived for half an hour(the
time is depends on the indoor unit or the setting of move eye),
the indoor unit will be o.
(2) Press MENU key, you will enter function circulation, use
or key to switch between dierent functions. Switch to
/ / function, then press MENU key again, / /
function will be turned on. If the function is turned on, /
/ icon will be displayed in the main interface.
In the state where the / / function is turned on,
if you want to turn it o, please enter function circulation and
switch to / / icon, then press MENU key , and the
function will be turned o.
(3) When the / function is turned on, if you adjust
swing angle, the / function will be turned o.
(4) / / functions cannot be turned on at the same
time. Only one function can exist at a time.
Motion sensing (only valid for part of models)
Other Haier Controllers manuals

Haier
Haier QACT17A User manual

Haier
Haier YR-E20 User manual

Haier
Haier HW-WA101DBT User manual

Haier
Haier HW-BA101ABT User manual

Haier
Haier YCZ-A001 User guide

Haier
Haier QACT17A User manual

Haier
Haier YCZ-A004 User manual

Haier
Haier RWV05 V2 User manual

Haier
Haier YCZ-A004 User manual

Haier
Haier QACT17A User manual
Popular Controllers manuals by other brands

YASKAWA
YASKAWA YRC1000 Startup guide

Agilent Technologies
Agilent Technologies TV70 Navigator Series user manual

RMG
RMG 672 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS

Digi-Sense
Digi-Sense TC9600 Advanced quick start guide

PPI
PPI Neuro 102EX user manual

Allegion
Allegion LCN 8310-813 installation instructions