Halma MEMCO Elite 618 User manual

ISSUE
PRODUCT
INFORMATION
SHEET
INFRA RED SAFETY CURTAIN FOR LIFTS
Greatly reduces damage to the lift doors
Microcontroller based TX and RX
81 criss-cross beams offer protection up to a height of 1.8m as required by EN81-
70:2003
Supplied with patented Power Reduction software
Designed for new and existing lifts
Diagnostic LEDs and timeout software
Robust 9mm wide profile
4m range
Fig 1: 618 Beam Pattern
INTRODUCTION
The Memco élite 618 safety system provides
a light curtain of infra-red beams operating
between the lift car doors. Any person or
object breaking the beams will trigger the
system and re-open the doors. The beam
pattern will pick up even small objects
between the car doors.
The 618 safety system consists of a transmitter
detector (TX) and a receiver detector (RX)
mounted on the car doors. The system will
automatically sense the door separation and
adjust itself for optimum performance. No
setting up is required.
In many installations a separate controller is
unnecessary and the detectors can be
connected direct to the lift controller or door
operator.
Memco Elite Model 618
OPERATION
Light Curtain Operation
The 618 light curtain uses 18 transmit diodes
in the TX detector and 18 receive diodes in
the RX detector. The light curtain uses an 81
beam pattern when the doors are fully open
(Fig 1). The pattern changes to 50 beams as
the doors close to approximately 650mm, and
maintains 18 beams right up to closure.
Surface mount technology has led to a great
improvement in the optics allowing diagonal
beams to function to almost door closure. The
diodes are manufactured using a technique
which improves both consistency and reliability.
The special lenses, unique to Memco, used in
conjunction with the surface mount diodes
optimise the system performance.
Trouble-Shooting LEDS
There are two red trouble-shooting LEDS
positioned 25cm and 31cm from the top of
the TX detector. The states they can indicate
are shown in Table 1.
Power Reduction Function
This software feature prolongs the life-span
of the detectors by putting them into a less
active state when the lift is not in use. It
automatically activates when the detectors
are stopped and close together for more than
10 seconds. In this mode scanning is reduced
to once every 2 seconds. If the doors start to
open, or an obstruction is detected then the
normal scanning and trigger mode is
resumed.
Timeout Function
This software feature allows up to 3 non-
adjacent light-curtain TX diodes to be ignored
if they are permanently obstructed. It is
automatically activated 10 seconds after a
beam is permanently blocked. This is a useful
service feature which enables detectors
defaced by vandalism to continue working
while arrangements are made to replace them.
System Connection
For trouble-free installation we recommend
installing the 618 system with a Memco 280
or 281 power supply. However in many
situations the 618 can be directly connected
to the lift controller or door operator.
The power supply is available in two versions;
the Model 280 is powered from an AC supply
(115 / 230V) while the Model 281 is powered
from a DC supply (15 - 36V).
Fig 2: 618 profile
Table 1: Trouble Shooting Guide
LED Status Possible Cause
OFF
OFF No Power
FLASHING
OFF TX/RX connection open circuit
ON Triggered state obstruction
OFF between detectors
ON Normal scanning state
ON
ON A diode has been timed out
FLASHING SLOWLY
37.3
9.0
24.0
Using a Memco 280/281 Power Supply
The Memco power supply provides:-
·a regulated DC supply for the 618
detectors.
·a relay output for connection to the car
door re-open circuit.
This eliminates concern about the electrical
environment into which the 618 is being
installed and makes wiring straightforward
(Fig 3).
The power supply also has a beeper which
sounds when an object is detected. A switch
is provided to disable this beeper. The unit is
factory-set for “failsafe” operation using
standard 618 (PNP-N/C) detectors, but
switches allows detectors with other
transistor configurations to be used.
Direct Connection
The 618 can be connected directly to the lift-
controller or door-operator if it has asuitable
power supply and “door reopen” circuit (Fig
4). The power supply must be regulated DC
(11-30V) with no transients. The door re-
open circuit must accept a transistor drive
and guarantee the signal current will never
exceed 100mA.
The standard 618 transistor configuration is
PNP Normally-Closed (PNP-N/C). A PNP
transistor means the load will be connected
between the output and 0V (i.e. when the
transistor is turned on the load will draw current
from the transistor output). Normally Closed
means the transistor is turned on when a
person or object is not being detected. Other
transistor configurations are available on
request but PNP Normally-Closed offers “fail-
safe” operation.
Contact Memco to discuss direct connection in
more detail.
Fig 3: Installation Wiring (timeout enabled)
TO DOOR OPERATOR OR LIFT CONTROLLER
MODEL 280 or 281 Power Supply
Fig 4: Using a Memco Power Supply
TX CABLE
0V - ORANGE
+12V - RED
TRIG - BLUE
LINK - WHITE or GREEN
RX CABLE
0V - ORANGE
+12V - YELLOW (Timeout Enabled)
LINK - WHITE or GREEN
Power Supply
Door Re-Open
Circuit
TO LIFT CONTROLLER
OR DOOR OPERATOR
DOOR RE-OPEN
DC SUPPLY (11-30V)
0V
ORANGE ‘0V’
YELLOW ‘Timeout’
WHITE or GREEN ‘Link’
‘DC Supply’ RED
‘Link’ WHITE or GREEN
‘0V’ ORANGE
‘Trig Output’ BLUE
MEMCO LTD, CLYDE HOUSE
REFORM ROAD, MAIDENHEAD
BERKS SL6 8BY, UK
TELEPHONE: +44 1628 770734
FACSIMILE: +44 1628 621947
www.memco.co.uk
DSHEET13/SPA/24.03.2011
618 SPECIFICATION
Detector size 9mm ( 3/8") x 37.3mm (11/2") x 2008mm (6' 71/16")
Fixing kit 10 x 6mm ‘P’ Clip
10 x No.6 x 20mm CSK screws
12 x No.8 12mm S/T screws
10 x No.6 16mm S/T Pan Head screws
10 x M3.5 shakeproof washers
2 x M4 shakeproof washers
Distance between bottom
beam and bottom of housing 20.5mm ( 13/16")
Distance between top
beam and bottom of housing 1834mm (6' 3/16")
Range 4m
Number of diodes per detector 18
Distance between diodes bottom 4 diodes 58.5mm, top 14 diodes 117mm
Number of beams 81 when detectors are more than 650mm apart, 50 when less than 650mm
apart, 18 when detectors are closer than approx 250mm
Input Voltage 11-30V DC max @ 80mA max (excluding PNP load current). Supply must
have a ripple voltage of no more than 36V peak
Output Stage NPN or PNP transistor (factory set)
Indicators 2 red LEDs on TX (visible through the lens)
Light immunity >100,000 lux
Operating temperature range -10°C to 55°C as per BS2011 Part2.1 Ab and Part 2.2 Bb
Temperature storage -20°C & 65°C for 16 hours at each temperature
High temperature/high humidity BS2011:Part2.1Db:1981, Variant2 at +55°C
EMC compliance Emissions to EN12015, Immunity to EN12016
IP Rating IP54 in accordance with BS EN60529:1992
Sleep Software Patent Nos UK 9822359.7
Germany 29918009.3
Japan 291527/1999
USA 09/416,585
Ordering Information
Normal Product Range
618 180 Set of Model 618 Detectors each with 2.7m cable PNP-N/C output
618 180-B Set of Model 618 Detectors each with 4m cable PNP-N/C output
Available on Request
618 080 Set of Model 618 Detectors each with 2.7m cable NPN-N/C output
618 090 Set of Model 618 Detectors each with 2.7m cable NPN-N/O output
618 190 Set of Model 618 Detectors each with 2.7m cable PNP-N/O output
Accessories
280 000 Power Supply: 115/230V AC
281 000 Power Supply: 15-36V DC
616 800-010 Static Fixing Kit
This product is designed for use in elevators with powered automatic doors where the closing force
is 25N/mm or less as per EN81 requirements. It should be installed by qualified personnel only, therefore
any use outside of this application is at the installer’s own risk and should be assessed appropriately.
As a result of our policy of continual improvement, the information in this document is subject to change
without notice and it is intended only as general guidance on product performance and suitability.
This information shall not form part of any contract.

This manual suits for next models

2

Other Halma Security Sensor manuals

Halma Apollo XP95 I.S. User manual

Halma

Halma Apollo XP95 I.S. User manual

Halma SENSITRON SMART3G-GrI User manual

Halma

Halma SENSITRON SMART3G-GrI User manual

Halma Ampac TITANUS MICRO-SENS User manual

Halma

Halma Ampac TITANUS MICRO-SENS User manual

Halma BEA IXIO Series User manual

Halma

Halma BEA IXIO Series User manual

Halma apollo REACH User manual

Halma

Halma apollo REACH User manual

Halma Ampac FastSense 25 Guide

Halma

Halma Ampac FastSense 25 Guide

Halma Ampac FastSense PLUS Guide

Halma

Halma Ampac FastSense PLUS Guide

Halma BEA ACTIV8 THREE ON User manual

Halma

Halma BEA ACTIV8 THREE ON User manual

Halma BEA IXIO Series User manual

Halma

Halma BEA IXIO Series User manual

Halma BEA G3 User manual

Halma

Halma BEA G3 User manual

Halma BEA IXIO-DO1 I User manual

Halma

Halma BEA IXIO-DO1 I User manual

Halma Apollo Marine 65 Series User manual

Halma

Halma Apollo Marine 65 Series User manual

Halma Apollo Marine 65 Series User manual

Halma

Halma Apollo Marine 65 Series User manual

Halma SENSITRON SMART3H-FM LITE User manual

Halma

Halma SENSITRON SMART3H-FM LITE User manual

Popular Security Sensor manuals by other brands

Crow SH-PIR-8F user manual

Crow

Crow SH-PIR-8F user manual

Crowcon FGard IR3 Installation, Operating and Maintenance Instruction

Crowcon

Crowcon FGard IR3 Installation, Operating and Maintenance Instruction

LG 17HQ701G-BP.AEU owner's manual

LG

LG 17HQ701G-BP.AEU owner's manual

ANDIG 5379 User handbook

ANDIG

ANDIG 5379 User handbook

Sperian Miller SafEscape ELITE operating manual

Sperian

Sperian Miller SafEscape ELITE operating manual

Zeiss BSD4 instruction manual

Zeiss

Zeiss BSD4 instruction manual

Mirion Technologies ACCURAD PRD operating manual

Mirion Technologies

Mirion Technologies ACCURAD PRD operating manual

C.Nord CN-Magnetic-Mini installation guide

C.Nord

C.Nord CN-Magnetic-Mini installation guide

Redwall LRP3020 Installation instruction

Redwall

Redwall LRP3020 Installation instruction

Menlo Systems FPD310-FV operating manual

Menlo Systems

Menlo Systems FPD310-FV operating manual

Optex VX-402R installation instructions

Optex

Optex VX-402R installation instructions

Proton SL mini 1220 instruction manual

Proton

Proton SL mini 1220 instruction manual

SGB VL Series Documentation

SGB

SGB VL Series Documentation

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Endress+Hauser

Endress+Hauser Nivotester FTL325N-**** Series operating instructions

Sun Microsystems FI316 user manual

Sun Microsystems

Sun Microsystems FI316 user manual

HOKUYO AUTOMATIC PBS-03JN-V01 instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC PBS-03JN-V01 instruction manual

SMART TL-2100CP Change Pad Indicator Installation and use instructions

SMART

SMART TL-2100CP Change Pad Indicator Installation and use instructions

Schaller Automation VN115/87plus EX Operation manual

Schaller Automation

Schaller Automation VN115/87plus EX Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.