6 Hampton®H35-2 Direct Vent Freestanding Gas Stove
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The DirectVentFreestandingGasStovemustbe
installed in accordance with these instructions.
Carefullyreadall the instructionsinthismanual
first. Consult the building authority having
jurisdiction to determine the need for a permit
prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
seriousbodilyinjury,and/orproperty
damage. Failure to follow these
instructions may also void your fire
insurance and/or warranty.
Note:Theseinstructionstakeprecedenceover
Simpson Dura-Vent instructions.
SPECIFICATIONS
Fuels: H35-NG2 is approved for use with
natural gas.
H35-LP2 is approved for use
with liquefied petroleum gases
(propane).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fibre, 7 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid flue and termination cap.
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and
was determined independent of any installed
system.
INFORMATION FOR
MOBILE /
MANUFACTURED
HOMES
AFTER FIRST SALE
This Hampton®product has been tested and
listed by ITS Testing Services as a Direct Vent
Wall Furnace to the following standards:
CGA-2.17-M91, and ANSI Z21.88b-2007/CSA
2.33b-2007.
This Direct Vent System Appliance must be
installedinaccordancewiththe manufacturer's
installation instructions and the Manufactured
INSTALLATION
Home Construction and Safety Standard, Title
24 CFR, Part 3280, or the current Standard
of Fire Safety Criteria for Manufactured
Home Installations, Sites, and Communities
ANSI/NFPA501A,andwithCAN/CSAZ240-MH
Mobile Home Standard in Canada.
This appliance installation must comply with
themanufacturer'sinstallationinstructionsand
localcodes,ifany.Intheabsenceoflocalcodes
followthecurrentNationalFuelGasCode,ANSI
Z223.1andthecurrentNationalElectricalCode
ANSI/NFPA 70 in the U.S.A., and the current
CAN/CSA B149.1 Gas Installation Code and
the current Canadian Electrical Code CSA
C22.1 in Canada.
This Hampton®Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the
unit.
This Hampton®Mobile/Manufactured
Homelistedappliance comesequipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
Thisappliancemayonlybeinstalledin
an aftermarket permanently located,
manufactured (USA only )or mobile
home, where not prohibited by local
codes.
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other gases,
unless a certified kit is used.
INSTALLATION AND REPAIRS SHOULD
BE DONE BY A QUALIFIED SERVICE
PERSON. THIS APPLIANCE SHOULD BE
INSTALLED, REPAIRED, INSPECTED BE-
FORE USEAND AT LEAST ANNUALLY BY
A QUALIFIED SERVICE PERSON. MORE
FREQUENTCLEANINGMAYBEREQUIRED
DUETOEXCESSIVELINTFROMCARPET-
ING, ETC. IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE AP-
PLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
BEFORE YOU START
Safeinstallationandoperationofthisappliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
1) Provide adequate clearances for servicing,
properoperationandaroundtheairopenings
into the combustion chamber.
2) The appliance must be installed on a flat,
solid,continuoussurface(e.g.wood,metal,
concrete).This maybethefloor,oritcanbe
raiseduponaplatformtoenhanceitsvisual
impact. The appliance may be installed on
carpeting, tile, wood flooring or other com-
bustible material, because the appliance's
baseextends the full width and depth of the
appliance. The Direct Vent Freestanding
GasStovecanbeinstalledinawide variety
of ways and will fit nearly any room layout.
It may be installed in a recessed position,
framed out into the room, or across a cor-
ner.
3) The Direct Vent Freestanding Gas Stove
is approved for alcove installations, which
meet the clearances listed in the "Clear-
ance to Combustibles" section. This unit is
approved for manufactured home installa-
tions, see the "Manufactured Mobile Home
Additional Requirements" section and the
"Venting Arrangement" section for the re-
quiredventarrangements.Ifinstalledintoa
manufacturedhome theunitmustbebolted
down to the floor.
4) ThisapplianceisListedfor bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5) This appliance is Listed for Alcove installa-
tions,maintainminimumAlcoveclearances
asfollows, minimumwidthof40"(1016mm),
a maximum depth of 36" (914mm), and
minimum ceiling height of 64" (1626mm)
from floor to ceiling.
6) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualifiedbuildinginspectorreviewyourplans
before installation.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACETEMPERATURES,ESPECIALLY
THE FIREPLACE GLASS, AND SHOULD
STAYAWAYTOAVOIDBURNSORCLOTH-
ING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISEDWHENTHEYAREIN
THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIALSHOULDNOTBEPLACEDON
OR NEAR THE APPLIANCE.