Hanil Supra R22 User manual

Quick Guide Supra R22 / Supra R12
Cat. No. : SU-R22 / SU-R12
Display & Control Panel
Pulse
PULSE
xg
VIEW
SETTINGS
Start Stop
Display Screen
Status of RPM / RCF / Time /
Temperature / Rotor ID /
ACC / DEC / Program
Setting Speed
Press once : Setting RPM
Press twice : Setting RCF
Setting Time
Up to < 100 hr
Continuous run (00:00)
Lid Open
Program Save / Call
Saving a program
(up to 100)
Calling up a program
Setting the Rotor ID manually
When rotor id is not identified
automatically, enter the rotor ID.
manually
Max. RPM : 22,000 rpm
Max. RCF : 57,358 xg
Max. RPM : 12,000 rpm
Max. RCF : 22,265 xg
Supra R12
Supra R22
Press the
Pulse button
Enter the desired speed
(See ‘Setting Run
Parameters’)
Serial No. Installation Date
Saving / Calling Up a Program
Press a parameter
to be changed
Press the
Enter button
Enter the desired values
on the keypad
Enter the desired
program number on
the keypad
Press the
Save or call button
Setting Run Parameters
(RPM / RCF / Time / Temperature / ACC / DEC)
Press the
Enter button
Press the
Temp. limit button
Press the
Enter button
Temperature range that stops operation when the temperature
is lower or higher than the set temperature.
Enter the desired
temperature range
on the keypad
Setting Temp. Limit
View Settings
Verifying the setting
parameters during
centrifugation
Pulse
After reaching the set
speed, the centrifugation
is decelated and stopped
Setting ACC / DEC Rate
ACC (0 ~ 9 steps, Max.9)
DEC (0 ~ 9 steps, Natural DEC.0)
Setting Temperature
Setting temperature ( -10℃ ~ 40℃)
Setting temp. limit
2 31
5 64
8 97
0
±
Connect the device to voltage
sources, which correspond to the
electrical requirements on the label
attached to the device.
Check the wall outlet is earth-
grounded, surge-protected and
can supply enough power.
Connect the power cable to the
distribution box, or install the plug
and socket that are packed with
the device.
Switch off the device after use.
Unplug the power plug before
cleaning or unused for a long
period of time.
Check the Line Voltage Grounded Outlet Power Connection Switch Off the Device
Quick Guide Supra R22 / Supra R12
Cat. No. : SU-R22 / SU-R12
Maintenance
Electrical safety
A2.0-36
A10-12
A15-12
A15c-12
A50-6
A50c-6
36 x 1.5/2.0 mL / Max. 18k
12 x 10 mL / Max. 22k
12x 15 mL / Max. 22k
12 x 15 mL conical / Max. 17k
6 x 50 mL / Max. 22k
6 x 50 mLconical / Max. 17k
6 x 250 mL / Max. 12k
6 x 500 mL / Max. 10k
4 x 1,000 mL / Max. 8k
6 x 1,000 mL / Max. 7k
A250-6
A500-6
A1000-4
A1000-6
Rotors
Allow a safety clearance of 30 cm
around the centrifuge during
operation.
Remove Dust Empty the Condensation WaterAllow a Safety Clearance of 30 cmEmergency Lid Open
30 cm
30 cm
30 cm
If the centrifuge lid cannot be opened, insert the
provided T-wrench into the emergency release
hole on the right side of the device and press it.
(Before activating emergency open, switch off
the device and wait for the rotor to stop.)
Remove any dust from the
ventilation slits on the right side
of the device.
Empty the condensation water
regularly by removing the drain cap
on the left side of the device.
8 x 50 mL / Max. 20k
6 x 85 mL / Max. 20k
6 x 250 mL / Max. 12k
6 x 500 mL / Max. 9k
4 x 1,000 mL / Max. 8k
A50-8
A85-6
A250-6
A500-6
A1000-4
Supra R22 Supra R12
Cautions for Use
Inspect the rotor, chamber,
rotor & accessories for foreign objects.
Check the Chamber & Accessories
Wipe up the moisture in the chamber with
a dry cloth after use. Keep the lid open
when not in use.
Clean the chamber and rotor
by wiping with a cloth soaked in mild
detergent and dry completely.
Keep the Chamber Dry
Cleaning
Load tubes symmetrically into the rotor
with identical amount.
Load Tubes Symmetrically
Check the rotor, buckets and tubes are free
of scratch and crack before operation.
Check the Accessories for Abnormalities
After relocating the device or loading the
rotor, balance them by using a leveler. If
necessary, level the device by adjusting the
‘Leveling foot’ on the bottom of the device.
Balancing the Centrifuge and Rotor
3.4KVA (Supra R22)
3.0KVA (Supra R12)
220~240V 50/60Hz
Rev.1
Proudly made by Jiyoung Shim, Hyewon Jeong
Order & Inquiry l +82-2-3472-0727 l [email protected] l www.ihanil.com
Service l +82-2-3452-8966 l [email protected]
Before Operation After Operation

This manual suits for next models

3

Other Hanil Control Panel manuals

Hanil Combi 508 User manual

Hanil

Hanil Combi 508 User manual

Hanil Smart 15 Plus User manual

Hanil

Hanil Smart 15 Plus User manual

Hanil Component R12 User manual

Hanil

Hanil Component R12 User manual

Hanil Supra R17 User manual

Hanil

Hanil Supra R17 User manual

Popular Control Panel manuals by other brands

Controls HARLO MVP-902 product manual

Controls

Controls HARLO MVP-902 product manual

Satel VERSA Series Programming manual

Satel

Satel VERSA Series Programming manual

Salda Ptouch user manual

Salda

Salda Ptouch user manual

Konica Minolta ViZion DR+ 1417V2 Dealers Installation manual

Konica Minolta

Konica Minolta ViZion DR+ 1417V2 Dealers Installation manual

Harris NUCLEUS Installation and operation manual

Harris

Harris NUCLEUS Installation and operation manual

Autonics Omron GP Series User Manual for Communication

Autonics

Autonics Omron GP Series User Manual for Communication

Sleipner 8950G user manual

Sleipner

Sleipner 8950G user manual

Balboa Water Group BP2 Series User Interface and Programming Reference

Balboa Water Group

Balboa Water Group BP2 Series User Interface and Programming Reference

Notifier 4812 instruction manual

Notifier

Notifier 4812 instruction manual

Warmup WSM-200W instruction manual

Warmup

Warmup WSM-200W instruction manual

ARRI Orbiter Short Instruction

ARRI

ARRI Orbiter Short Instruction

RESEARCH CONCEPTS RC4600 Operator's manual

RESEARCH CONCEPTS

RESEARCH CONCEPTS RC4600 Operator's manual

Simplicity 64 installation manual

Simplicity

Simplicity 64 installation manual

Schrack Seconet Integral MAP user manual

Schrack Seconet

Schrack Seconet Integral MAP user manual

Riello 20147241 Instruction booklet

Riello

Riello 20147241 Instruction booklet

marklin 72720 quick start guide

marklin

marklin 72720 quick start guide

Global Fire Equipment JUNIOR MINI-REP installation manual

Global Fire Equipment

Global Fire Equipment JUNIOR MINI-REP installation manual

Kramer RC-76M user manual

Kramer

Kramer RC-76M user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.