HI713
Phosphate Low Range
INSTRUCTION MANUAL
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI713-25 Reagents for 25 Phosphate Low Range tests
Other Accessories
HI713-11 Phosphate LR Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST713 05/18
HI713 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 3 minutes of non-use and 2 minutes
after reading.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking,
the meter is ready.
• Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
• Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
• Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI713-0 reagent. Replace the cap
and shake gently for 2 minutes until the
powder is completely dissolved. Place the
cuvette back into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 3 minutes and press the
button.
• The instrument directly displays the
concentration of phosphate in ppm. The
meter automatically turns off after 2 minutes.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you use
the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI713 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0.00 to 2.50 ppm
Resolution 0.01 ppm
Accuracy ±0.04 ppm ±4% of reading @25 °C/77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method
Adaptation of the Standard Methods for the Examination of Water
and Wastewater, 20th edition, Ascorbic Acid method. The reaction
between phosphate and the reagent causes a blue tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 3 minutes of non-use and 2 minutes after reading
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications

Other manuals for HI 713

5

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI96719C User manual

Hanna Instruments

Hanna Instruments HI96719C User manual

Hanna Instruments BL 7916 User manual

Hanna Instruments

Hanna Instruments BL 7916 User manual

Hanna Instruments HI 84185 User manual

Hanna Instruments

Hanna Instruments HI 84185 User manual

Hanna Instruments HI 5315 User manual

Hanna Instruments

Hanna Instruments HI 5315 User manual

Hanna Instruments pH 211 User manual

Hanna Instruments

Hanna Instruments pH 211 User manual

Hanna Instruments HI 96741C User manual

Hanna Instruments

Hanna Instruments HI 96741C User manual

Hanna Instruments HI 84181 User manual

Hanna Instruments

Hanna Instruments HI 84181 User manual

Hanna Instruments HI96725C User manual

Hanna Instruments

Hanna Instruments HI96725C User manual

Hanna Instruments HI 110 User manual

Hanna Instruments

Hanna Instruments HI 110 User manual

Hanna Instruments HI 713 User manual

Hanna Instruments

Hanna Instruments HI 713 User manual

Hanna Instruments HI 96721 User manual

Hanna Instruments

Hanna Instruments HI 96721 User manual

Hanna Instruments HI6421 User manual

Hanna Instruments

Hanna Instruments HI6421 User manual

Hanna Instruments HI 2222 User manual

Hanna Instruments

Hanna Instruments HI 2222 User manual

Hanna Instruments HI 99131 User manual

Hanna Instruments

Hanna Instruments HI 99131 User manual

Hanna Instruments HI 96762C User manual

Hanna Instruments

Hanna Instruments HI 96762C User manual

Hanna Instruments HI97752 User manual

Hanna Instruments

Hanna Instruments HI97752 User manual

Hanna Instruments HI 93701 User manual

Hanna Instruments

Hanna Instruments HI 93701 User manual

Hanna Instruments HI97729 User manual

Hanna Instruments

Hanna Instruments HI97729 User manual

Hanna Instruments Checker HI772 User manual

Hanna Instruments

Hanna Instruments Checker HI772 User manual

Hanna Instruments HI 96707C User manual

Hanna Instruments

Hanna Instruments HI 96707C User manual

Hanna Instruments HI 93124 User manual

Hanna Instruments

Hanna Instruments HI 93124 User manual

Hanna Instruments HI 723 User manual

Hanna Instruments

Hanna Instruments HI 723 User manual

Hanna Instruments Checker HI726 User manual

Hanna Instruments

Hanna Instruments Checker HI726 User manual

Hanna Instruments HI 720 User manual

Hanna Instruments

Hanna Instruments HI 720 User manual

Popular Measuring Instrument manuals by other brands

Keysight N5244AU- H29 Installation note

Keysight

Keysight N5244AU- H29 Installation note

DEELAT D1140772 user manual

DEELAT

DEELAT D1140772 user manual

Panametrics PanaFlow LZ user manual

Panametrics

Panametrics PanaFlow LZ user manual

Fiso Nortech EasyTest II user guide

Fiso

Fiso Nortech EasyTest II user guide

PCB Piezotronics W356A12/004CA Installation and operating manual

PCB Piezotronics

PCB Piezotronics W356A12/004CA Installation and operating manual

PCE Americas PCE-WM 1 manual

PCE Americas

PCE Americas PCE-WM 1 manual

Taxitronic TX52 installation manual

Taxitronic

Taxitronic TX52 installation manual

Camlogic CLC40 Installation and Maintenance

Camlogic

Camlogic CLC40 Installation and Maintenance

Endress+Hauser SmarTec S CLD 132 PROFIBUS-PA operating instructions

Endress+Hauser

Endress+Hauser SmarTec S CLD 132 PROFIBUS-PA operating instructions

ROMWARE RADIUS quick start guide

ROMWARE

ROMWARE RADIUS quick start guide

Elvaco CMi4110 quick start guide

Elvaco

Elvaco CMi4110 quick start guide

METER G3 manual

METER

METER G3 manual

Measurement Systems MSI5300 user guide

Measurement Systems

Measurement Systems MSI5300 user guide

Trumeter APM manual

Trumeter

Trumeter APM manual

HKC APL-4 Series Installation, operation & maintenance manual

HKC

HKC APL-4 Series Installation, operation & maintenance manual

CHN Spec CS-810 Operation manual

CHN Spec

CHN Spec CS-810 Operation manual

Trotec BW10 operating manual

Trotec

Trotec BW10 operating manual

Sierra RedyIndustrial Series quick start guide

Sierra

Sierra RedyIndustrial Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.