Hanna Instruments HI749 User manual

HI749
Chromium VI Low Range
INSTRUCTION MANUAL
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI749-25 Reagents for 25 Chromium VI Low Range tests
Other Accessories
HI749-11 Chromium VI LR Certified Standard Kit
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette seal cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST749 05/18
HI749 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C1” with “Press” blinking, the
meter is ready.
• Fill the cuvette with 10 mL of unreacted sample
and replace the cap. Place the cuvette into the
meter and close the meter’s cap.
• Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
• Remove the cuvette from the meter and unscrew
the cap. Add the content of one packet of
HI749-0 reagent. Replace the cap and shake
vigorously for about 10 seconds. Place the
cuvette back into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait 6 minutes and press the
button.
• The instrument directly displays the
concentration of chromium VI in ppb. The
meter automatically turns off after 10 minutes.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI749 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0 to 300 ppb
Resolution 1 ppb
Accuracy ±3 ppb ±5% of reading @25 °C/77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method
Adaptation of the ASTM Manual of Water and Environmental Technol-
ogy, D1687-92, Diphenylcarbohydrazide method. The reaction be-
tween chromium VI and the reagent causes a purple tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 991003 User manual

Hanna Instruments

Hanna Instruments HI 991003 User manual

Hanna Instruments HI 96745 User manual

Hanna Instruments

Hanna Instruments HI 96745 User manual

Hanna Instruments HI6321 User manual

Hanna Instruments

Hanna Instruments HI6321 User manual

Hanna Instruments HI98198/10 User manual

Hanna Instruments

Hanna Instruments HI98198/10 User manual

Hanna Instruments HI 717 User manual

Hanna Instruments

Hanna Instruments HI 717 User manual

Hanna Instruments HI 95721C User manual

Hanna Instruments

Hanna Instruments HI 95721C User manual

Hanna Instruments HI 9828 User manual

Hanna Instruments

Hanna Instruments HI 9828 User manual

Hanna Instruments HI 96761C User manual

Hanna Instruments

Hanna Instruments HI 96761C User manual

Hanna Instruments HI96726 User manual

Hanna Instruments

Hanna Instruments HI96726 User manual

Hanna Instruments HI97752 User manual

Hanna Instruments

Hanna Instruments HI97752 User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI 93705 User manual

Hanna Instruments

Hanna Instruments HI 93705 User manual

Hanna Instruments HI 98127 User manual

Hanna Instruments

Hanna Instruments HI 98127 User manual

Hanna Instruments pH 210 User manual

Hanna Instruments

Hanna Instruments pH 210 User manual

Hanna Instruments HI775 User manual

Hanna Instruments

Hanna Instruments HI775 User manual

Hanna Instruments HI 93734 User manual

Hanna Instruments

Hanna Instruments HI 93734 User manual

Hanna Instruments pHep+ HI 98108 User manual

Hanna Instruments

Hanna Instruments pHep+ HI 98108 User manual

Hanna Instruments HI 4107 User manual

Hanna Instruments

Hanna Instruments HI 4107 User manual

Hanna Instruments HI 95715 User manual

Hanna Instruments

Hanna Instruments HI 95715 User manual

Hanna Instruments 96728 User manual

Hanna Instruments

Hanna Instruments 96728 User manual

Hanna Instruments HI 93701 User manual

Hanna Instruments

Hanna Instruments HI 93701 User manual

Hanna Instruments HI6421 User manual

Hanna Instruments

Hanna Instruments HI6421 User manual

Hanna Instruments HI 9214 User manual

Hanna Instruments

Hanna Instruments HI 9214 User manual

Hanna Instruments HI84534-01 User manual

Hanna Instruments

Hanna Instruments HI84534-01 User manual

Popular Measuring Instrument manuals by other brands

Anritsu MP1220A Operation manual

Anritsu

Anritsu MP1220A Operation manual

Snooper Tyre Pilot STP 1400 user manual

Snooper

Snooper Tyre Pilot STP 1400 user manual

SMC Networks IZE11 Series Operation manual

SMC Networks

SMC Networks IZE11 Series Operation manual

Vega VEGAWAVE Supplementary instructions

Vega

Vega VEGAWAVE Supplementary instructions

ADA INSTRUMENTS ProDigit MICRO operating manual

ADA INSTRUMENTS

ADA INSTRUMENTS ProDigit MICRO operating manual

WATANABE WPMZ-1 instruction manual

WATANABE

WATANABE WPMZ-1 instruction manual

Delta DPM-C530A user manual

Delta

Delta DPM-C530A user manual

AquaLabo TOXmini operating manual

AquaLabo

AquaLabo TOXmini operating manual

Bamo 9336 user manual

Bamo

Bamo 9336 user manual

GW Instek GSP-730 user manual

GW Instek

GW Instek GSP-730 user manual

Apogee Instruments SI-100 Series owner's manual

Apogee Instruments

Apogee Instruments SI-100 Series owner's manual

Keysight N5232A Option 200 Installation note

Keysight

Keysight N5232A Option 200 Installation note

PQ Plus UMD 98 Quick start manual

PQ Plus

PQ Plus UMD 98 Quick start manual

TE Connectivity DRS-CT-3P-MOD-2T user manual

TE Connectivity

TE Connectivity DRS-CT-3P-MOD-2T user manual

TPS 901-C manual

TPS

TPS 901-C manual

Magnescale MJ632 instruction manual

Magnescale

Magnescale MJ632 instruction manual

SmartSynch Itron Centron SmartMeter user guide

SmartSynch

SmartSynch Itron Centron SmartMeter user guide

Schmidt HTG Series operating instructions

Schmidt

Schmidt HTG Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.