manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments HI771 User manual

Hanna Instruments HI771 User manual

HI771
Chlorine Ultra High Range
INSTRUCTION MANUAL
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI771-25 Reagents for 25 Chlorine Ultra High Range tests
Other Accessories
HI771-11 Chlorine UHR Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass Cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST771 05/18
HI771 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking, the
meter is ready.
• Fill the cuvette with 10 mL of unreacted sample
and replace the cap. Place the cuvette into the
meter and close the meter’s cap.
• Press the button. When the display shows “Add”,
“C.2” with “Press” blinking the meter is zeroed.
• Remove the cuvette from the meter and unscrew
the cap. Add the content of one packet of
HI771A-0 reagent and one packet of HI771B-0
reagent.
• Replace the cap and shake gently for 20 seconds.
Place the cuvette back into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 1 minute and press the
button.
• The instrument displays concentration in ppm of
chlorine. The meter automatically turns off after
10 minutes.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must
be replaced. Once this indication is displayed, normal operation of
the instrument will be interrupted. Change the battery and restart
the meter.
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI771 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0 to 500 ppm
Resolution 1 ppm
Accuracy ±3 ppm ±5% of reading @25 °C/77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method Adaptation of the Standard Methods for the Examination of Water
and Wastewater, 20th edition, 4500-Cl.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 96750 User manual

Hanna Instruments

Hanna Instruments HI 96750 User manual

Hanna Instruments HI 99191 User manual

Hanna Instruments

Hanna Instruments HI 99191 User manual

Hanna Instruments HI 991002 User manual

Hanna Instruments

Hanna Instruments HI 991002 User manual

Hanna Instruments HI 991003 User manual

Hanna Instruments

Hanna Instruments HI 991003 User manual

Hanna Instruments HI-96730 User manual

Hanna Instruments

Hanna Instruments HI-96730 User manual

Hanna Instruments HI 96738C User manual

Hanna Instruments

Hanna Instruments HI 96738C User manual

Hanna Instruments HI97746 User manual

Hanna Instruments

Hanna Instruments HI97746 User manual

Hanna Instruments HI 93748 User manual

Hanna Instruments

Hanna Instruments HI 93748 User manual

Hanna Instruments HI 9023C User manual

Hanna Instruments

Hanna Instruments HI 9023C User manual

Hanna Instruments HI 93707 User manual

Hanna Instruments

Hanna Instruments HI 93707 User manual

Hanna Instruments HI9064 User manual

Hanna Instruments

Hanna Instruments HI9064 User manual

Hanna Instruments C 215 User manual

Hanna Instruments

Hanna Instruments C 215 User manual

Hanna Instruments HI 701 User manual

Hanna Instruments

Hanna Instruments HI 701 User manual

Hanna Instruments HI98194 User manual

Hanna Instruments

Hanna Instruments HI98194 User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI764 User manual

Hanna Instruments

Hanna Instruments HI764 User manual

Hanna Instruments pH 211R User manual

Hanna Instruments

Hanna Instruments pH 211R User manual

Hanna Instruments HI 93716 User manual

Hanna Instruments

Hanna Instruments HI 93716 User manual

Hanna Instruments HI 746 User manual

Hanna Instruments

Hanna Instruments HI 746 User manual

Hanna Instruments HI 60503 User manual

Hanna Instruments

Hanna Instruments HI 60503 User manual

Hanna Instruments HI 83742 User manual

Hanna Instruments

Hanna Instruments HI 83742 User manual

Hanna Instruments HI 717 User manual

Hanna Instruments

Hanna Instruments HI 717 User manual

Hanna Instruments HI96747C User manual

Hanna Instruments

Hanna Instruments HI96747C User manual

Hanna Instruments HI83141-1 User manual

Hanna Instruments

Hanna Instruments HI83141-1 User manual

Popular Measuring Instrument manuals by other brands

Tektronix 1502B Service manual

Tektronix

Tektronix 1502B Service manual

Endress+Hauser Proline Prosonic Flow 93 Function manual

Endress+Hauser

Endress+Hauser Proline Prosonic Flow 93 Function manual

Sealey TA203.V2 instructions

Sealey

Sealey TA203.V2 instructions

Keysight x series Installation notes

Keysight

Keysight x series Installation notes

KJ Instrument KJ6013 Operation manual

KJ Instrument

KJ Instrument KJ6013 Operation manual

KROHNE OPTIFLUX 2070 Handbook

KROHNE

KROHNE OPTIFLUX 2070 Handbook

Veris Industries E51C2A installation guide

Veris Industries

Veris Industries E51C2A installation guide

RTX 6001 user manual

RTX

RTX 6001 user manual

Siemens SENTRON PAC4200 manual

Siemens

Siemens SENTRON PAC4200 manual

MARTINDALE TEK100 instruction manual

MARTINDALE

MARTINDALE TEK100 instruction manual

MRC DI-900 Operation manual

MRC

MRC DI-900 Operation manual

Elcon SA10A user manual

Elcon

Elcon SA10A user manual

Schroeder Industries HY-TRAX Operating and maintenance instructions

Schroeder Industries

Schroeder Industries HY-TRAX Operating and maintenance instructions

MSI 2000 Programming manual

MSI

MSI 2000 Programming manual

WAGNER C575 instruction manual

WAGNER

WAGNER C575 instruction manual

Newport 1825-C Operator's manual

Newport

Newport 1825-C Operator's manual

jwLabs A3 Instruction manuals

jwLabs

jwLabs A3 Instruction manuals

Endress+Hauser Prosonic S FMU90 operating instructions

Endress+Hauser

Endress+Hauser Prosonic S FMU90 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.