Hanna Instruments Checktemp HI 98501 User manual

Hanna Instruments Inc. 584 Park East Drive
Woonsocket, RI 02895
www.hannainst.com
www.hannainst.com
HI 98501 (Checktemp®)
Instruction Manual
[email protected]
www.ponpe.com
Thank You!
Thank you for choosing a Hanna Instruments
product. Please read this instruction manual
carefully before using the instrument. For
additional information, visit www.hannainst.com
or e-mail us at tech@hannainst.com.
Specications
Operation
Turn Checktemp® ON with ON/OFF button: all LCD
segments are displayed for 1 second, and CalCheck®
starts automatically to verify that Checktemp®
of “CAL“ and “-0-“ means that Checktemp® is
measuring temperature, remember that:
·The temperature sensor is located at the tip
of the stainless steel probe.
·It is necessary to wait for a few seconds for
the display to stabilize.
Liquid Crystal Display
ON/OFF button
Maximum Immersion Level
Temperature Probe
4 cm
1.5”
Battery
Setup
Button
Recommended
Immersion Level
Range -50.0 to 150.0 ºC / -58.0 to 302 ºF
Resolution 0.1 ºC (-50.0 to 150.0 ºC)
0.1 ºF (-58.0 to 199.9 ºF) / 1 ºF (above 200 ºF)
Accuracy
±0.2 ºC (-30.0 to 120.0 ºC)
±0.3 ºC (outside: -50.0 to -30.0 ºC
and 120.0 to 150.0 ºC)
±0.5 ºF (-22.0 to 199.9 ºF)
±1 ºF (outside: -58.0 to -22.0 ºF
and 200 to 302 ºF)
Environment -30 to 50 ºC (-22 to 122 ºF)
Battery Type 1 x CR2032
Battery Life approx. 2000 hours of continuous use
Auto O 8 min (default), 60 min or OFF
Dimensions 50 x 185 x 21 mm (2 x 7.3 x 0.9“)
Weight 50 g (1.8 oz.)
All rights are reserved. Reproduction in whole or in part is
prohibited without the written consent of the copyright owner,
Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
IST98501
09/14
Warranty
Checktemp® is guaranteed for a period of one year after date of purchase
against defects in workmanship and materials when used for their intended
purpose and maintained according to instructions. This warranty is limited
to repair or replacement free of charge. Damage due to accidents, misuse,
tampering or lack of prescribed maintenance is not covered. If service is
required, contact your local Hanna Oce. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If
the repair is not covered by the warranty, you will be notied of the charges
incurred. If the instrument is to be returned to Hanna Instruments, rst
obtain a Returned Goods Authorization number from the Technical Service
department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Recommendations for Users
Before using Hanna Products, make sure that they are entirely suitable for
your specic application and for the environment in which they are used.
Operation of these instruments may cause unacceptable interferences to
other electronic equipment, thus requiring the operator to take all necessary
steps to correct such interferences. Batteries should only be replaced in a
safe area using the battery type specied in this instruction manual. Any
variation introduced by the user to the supplied equipment may degrade the
instrument’s EMC performance. To avoid damages or burns, do not put the
instrument in microwave oven. For yours and the instrument safety do not
use or store the instrument in hazardous environments.
Meter Setup
Enter Setup to change the temperature unit (ºC or
Setup MODE, press the SET button located inside
the battery compartment once for temperature
·Use the ON/OFF button to switch between
“ºC” or “ºF”. Press SET once to save and continue
to auto shut o settings.
·Use the ON/OFF button to cycle through the
following Auto Shut O options: 8 minutes
(“d08”, default value), 60 minutes (“d60”),
OFF (“d--”). Press the SET button once to save
and continue to normal operation.
Battery Replacement
Replace the battery when the battery symbol is
blinking or when Checktemp® does not switch
on. If the meter has been submerged in a liquid,
make sure it has been completely dried. Check the
polarity of the battery, open the compartment, and
replace the battery. Close battery cover.
Note: Batteries should only be replaced in a safe area using the battery
type specied in this instruction manual. Old batteries should be disposed in
accordance with local regulations.
Troubleshooting
Errors that may occur: A message of “CAL” and
“Err” means an internal error has occurred and
Checktemp® is not guaranteed to be within its
and the display shows “---” the temperature
connection to the probe has been broken. If a
message of “Err” occurs then a calibration data
read error has occurred. A message of “Er1” is
caused by an unexpected device reset. A message
of “Er2” occurs if internally a temperature
measurement malfunctions. After these messages
Checktemp® OFF and then ON with the ON/OFF
button to reset. If the error message continues to
Certication EN 13485:2001 - Suitability: Storage;
Environment: E; Accuracy Class: 0.5; IP65
EN 13485
Storage
E / 0.5
www.ponpe.com
[email protected]

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 92804 User manual

Hanna Instruments

Hanna Instruments HI 92804 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI 8757 User manual

Hanna Instruments

Hanna Instruments HI 8757 User manual

Hanna Instruments HI 98710 User manual

Hanna Instruments

Hanna Instruments HI 98710 User manual

Hanna Instruments HI 93531 User manual

Hanna Instruments

Hanna Instruments HI 93531 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 9040 User manual

Hanna Instruments

Hanna Instruments HI 9040 User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments

Hanna Instruments Foodcare HI9350011 User manual

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments Checktemp HI98501 User manual

Hanna Instruments

Hanna Instruments Checktemp HI98501 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 955501 User manual

Hanna Instruments

Hanna Instruments HI 955501 User manual

Hanna Instruments HI 145-01 User manual

Hanna Instruments

Hanna Instruments HI 145-01 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments Checktemp 1 User manual

Hanna Instruments

Hanna Instruments Checktemp 1 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 145-00 User manual

Hanna Instruments

Hanna Instruments HI 145-00 User manual

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments HI 98501-1 User manual

Hanna Instruments

Hanna Instruments HI 98501-1 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Popular Thermometer manuals by other brands

Oregon Scientific RAR232 user manual

Oregon Scientific

Oregon Scientific RAR232 user manual

TFA 30.136 operating instructions

TFA

TFA 30.136 operating instructions

ADE BBQ 1408 operating manual

ADE

ADE BBQ 1408 operating manual

Omron MC-520-E instruction manual

Omron

Omron MC-520-E instruction manual

Ryobi RP4030 user manual

Ryobi

Ryobi RP4030 user manual

VOLTCRAFT IR-1600 CA operating instructions

VOLTCRAFT

VOLTCRAFT IR-1600 CA operating instructions

GREISINGER GMH 3221 operating manual

GREISINGER

GREISINGER GMH 3221 operating manual

GHM GREISINGER G 1700 Series Compact manual

GHM

GHM GREISINGER G 1700 Series Compact manual

Ningbo ZY-NIT-3 instruction manual

Ningbo

Ningbo ZY-NIT-3 instruction manual

Hans Dinslage Sanitas SFT 65 Instructions for use

Hans Dinslage

Hans Dinslage Sanitas SFT 65 Instructions for use

Westfalia 97 03 10 instructions

Westfalia

Westfalia 97 03 10 instructions

Taylor 1542 instruction manual

Taylor

Taylor 1542 instruction manual

Microlife MT 50 quick start guide

Microlife

Microlife MT 50 quick start guide

BIOS Diagnostics 100DC instruction manual

BIOS Diagnostics

BIOS Diagnostics 100DC instruction manual

Omron MC-110 instruction manual

Omron

Omron MC-110 instruction manual

TFA 30.1009 instruction manual

TFA

TFA 30.1009 instruction manual

Emerson Dixell XT11S user manual

Emerson

Emerson Dixell XT11S user manual

Swiss Brand dr+ Frei T-10 user manual

Swiss Brand

Swiss Brand dr+ Frei T-10 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.