manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Thermometer
  8. •
  9. Hanna Instruments HI 9060 User manual

Hanna Instruments HI 9060 User manual

www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction and
appearance of its products without advance notice.
WARRANTY
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct opera-
tion. Please read it carefully before using the meter. If you
need additional technical information, do not hesitate to e-
mail us at [email protected].
This instrument is in compliance with the directives.
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
This Instrument is in
Compliance with CE
Directives
SPECIFICATIONS
Instruction Manual
HI 9060
PortableWaterproof
Microprocessor-based
Thermistor
Thermometer
Remove the instrument from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable damage,
notify your Dealer or the nearest Hanna Office.
Note: Save all packing materials until you are sure that the
instrument functions correctly. Any defective item must
be returned in the original packaging together with
the supplied accessories.
Range
Resolution
Accuracy
Typical EMC
Deviation
Display
Battery Type
Life
Probe (included)
Environment
Dimensions
Weight
1. Battery cover
2. Temperature probe connector
3. Liquid Crystal Display
4. ON/OFF Key
5. Measuring unit selection key
6. HOLD measurement key
7. HI/LO values reset key
HI 9060 is a waterproof, microprocessor-based, thermistor
thermometer, ideal for use in wet and humid environments.
The meter is also provided with low battery detection and
BEPS (Battery Error Preventing System), which turns the
unit off when the batteries are discharged avoiding errone-
ous readings caused by low battery level.
HI 9060 features include a dual-level LCD for simultaneously
displaying of maximum and minimum measured tempera-
tures, °C/°F selection button and hold function.
Each meter is supplied complete with HI 765BL temperature
probe, 4 x 1.5V AA batteries and instruction manual.
1. Current temperature value
2. HOLD indicator
3. Low Battery indicator
4. Minimum temperature value
5. Maximum temperature value
6. Measuring scale, °C or °F
CE DECLARATION OF CONFORMITY
ISTR9060 01/03
All Hanna Instruments meters are warranted for two years against
defects in workmanship and materials when used for their intended pur-
pose and maintained according to instructions. Sensors and probes are
warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed main-
tenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer
Service department, then return the instrument with the Authorization #
included along with shipment costs prepaid. If the repair is not covered by
the warranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for
complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.
-50.0 to 150.0°C / -58.0 to 302.0°F
0.1°C or 0.1°F
±0.4°C / ±0.8°F
excluding probe error
±1°C / ±2°F, with HI 765BL probe
Dual-line LCD
4 x 1.5V AA (IEC LR6)
approx. 3000 hours of continuous use
HI 765BL with 1 m (3.3') cable
-10 to 50ºC (14 to 122ºF); RH 100%
196 x 80 x 60 mm (7.7x3.1x2.4")
425 g (15 oz) meter only
OPERATIONAL GUIDE
INITIAL PREPARATION
Each meter is supplied complete with
batteries.
Remove the back cover, unwrap the
batteries and install them while pay-
ing attention to their polarity.
Connect the temperature probe to
the connector on the top of the
meter.
To switch on, press the ON/OFF key
on the front of the meter.
If the meter does not come on,
make sure that the batteries are correctly installed.
The thermometer will carry out a self diagnostic test routine,
the LCD will show all segments for a few seconds (or as long
as ON/OFF is held), followed by the
percentage indication of the remain-
ing battery life.
The thermometer then enters normal measurement mode.
If a temperature probe is plugged in, the meter displays
the measured temperature.
If no probe is plugged in, or if
reading is over-range, the display
shows flashing dashes.
If a measurement is slightly over the range of the meter
specifications, the display flashes the closest full-scale value.
To switch the thermometer OFF, press the ON/OFF key.
MEASURING SCALE (°C/°F)
Theinstrument is factoryset to the°C scale, butmeasurements
can be performed in either the Celsius or Fahrenheit scale.
Press the °C/°F button to select the
desiredscale.
HOLD MODE
The HOLD function is activated by
pressing the HOLD key.
The measured temperature is held on
the display until HOLD is pressed
again.
The "H" tag blinks on the display to
indicate the HOLD mode.
BATTERY REPLACEMENT
The instrument is powered by four 1.5 V alkaline batteries
and is provided with the Battery Error Prevention System
(BEPS), which turns the unit off when a low battery signal
is detected.
When the remaining battery level is
less than 10%, a warning symbol
blinks on the display to indicate a
low battery condition.
It is recommended to replace the batteries as soon as the
low battery condition is detected.
Battery replacement must only take place in a nonhazard-
ous area using four 1.5V alkaline batteries.
In order to replace rundown batteries, simply remove the
two screws on the rear cover of the instrument and replace
the four batteries with new ones paying attention to the
correct polarity.
Reattach the cover and tighten the two screws.
All Hanna thermometers have been accurately pre-calibrated
at the factory.
It is recommended to have all thermometers recalibrated at
least once a year. For an accurate annual recalibration,
contact your nearest Hanna Service Center.
Hanna Accuracy Test Plugs provide a quick and easy way
to test the meter's accuracy by simply connecting these Test
Plugs to the probe connector of the meter. If the reading
differs by more than ±0.4°C (±0.8°F) from the Test Plug
value, the meter is due for recalibration. Choose the Test
Plug closest to your measurement range to best suit your
needs:
HI 765-18C Calibration key, –18.0°C
HI 765000C Calibration key, 0.0°C
HI 765070C Calibration key, 70.0°C
HI 765-004F Calibration key, –0.4°F
HI 765032F Calibration key, 32.0°F
HI 765158F Calibration key, 158.0°F
FACTORY RECALIBRATION
Note: Although the display is frozen, internally the meter
continues measuring and updating Hi and Lo values.
HIGH/LOW TEMPERATURES
The maximum and minimum tem-
peratures are continuously monitored
and displayed in the lower portion of
the LCD.
Note: When reading goes over-range, the Hi and Lo values
display dashes until cleared.
CLEAR FUNCTION
Upon pressing the CLEAR key, the
current reading is assigned to the
highest and lowest temperature val-
ues. The High/Low values may be
cleared at any time during measure-
ment.
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which
they are used.
Operation of these instruments in residential areas could cause unacceptable interference to radio
and TV equipment, requiring the operator to take all necessary steps to correct interference.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance.
To avoid electrical shock, do not use these instruments when voltage at the measurement surface
exceeds 24VAC or 60VDC.
To avoid damage or burns, do not perform any measurement in microwave ovens.
TEMPERATURE PROBES & ACCESSORIES
Hanna offers a wide range of probes to meet your needs
with air, liquid, penetration and surface measurements.
All Hanna temperature probes are pre-calibrated at the
factory and ready-to-use. These interchangeable probes
make it possible to switch from one probe to another
without requiring recalibration.
Hanna probes are also available in different handle colors
to avoid cross contamination during testing.
PROBES WITH 1 m(3.3’) CABLE
HI 765A Air probe with white handle
HI 765BL General purpose liquid probe with black handle
HI 765L General purpose liquid probe with white handle
HI 765PBL General purpose penetration probe with blue
handle
HI 765PG General purpose penetration probe with green
handle
HI 765PR General purpose penetration probe with red
handle
HI 765PW General purpose penetration probe with white
handle
HI 765PWL Penetration probe with white handle
HI 765W Wire probe without handle for hard-to-reach
places
PROBES WITH 10 m(33’) CABLE
HI 765A/10 Air probe with white handle
HI 765L/10 General purpose liquid probe with white handle
HI 765PBL/10 General purpose penetration probe with
blue handle
HI 765PG/10 General purpose penetration probe with green
handle
HI 765PR/10 General purpose penetration probe with red
handle
HI 765PW/10 General purpose penetration probe with white
handle
HI 765W/10 Wire probe without handle for hard-to-reach
places
OTHER ACCESSORIES
HI 710002 Soft carrying case
HI 721317 Hard carrying case (340x230x90 mm)
HI 721308 1.5V AA size, alkaline battery (10 pcs)

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 98509-1 User manual

Hanna Instruments

Hanna Instruments HI 98509-1 User manual

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments HI 93531 User manual

Hanna Instruments

Hanna Instruments HI 93531 User manual

Hanna Instruments HI145-00 User manual

Hanna Instruments

Hanna Instruments HI145-00 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments Checktemp HI98501 User manual

Hanna Instruments

Hanna Instruments Checktemp HI98501 User manual

Hanna Instruments HI 92804 User manual

Hanna Instruments

Hanna Instruments HI 92804 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments HI 93530 User manual

Hanna Instruments

Hanna Instruments HI 93530 User manual

Hanna Instruments HI 146-01 User manual

Hanna Instruments

Hanna Instruments HI 146-01 User manual

Hanna Instruments HI98517/HI98518 User manual

Hanna Instruments

Hanna Instruments HI98517/HI98518 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 9061 User manual

Hanna Instruments

Hanna Instruments HI 9061 User manual

Hanna Instruments HI 93510N User manual

Hanna Instruments

Hanna Instruments HI 93510N User manual

Hanna Instruments HI 9043 User manual

Hanna Instruments

Hanna Instruments HI 9043 User manual

Hanna Instruments HI 98501-1 User manual

Hanna Instruments

Hanna Instruments HI 98501-1 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 92840 User manual

Hanna Instruments

Hanna Instruments HI 92840 User manual

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments

Hanna Instruments Checkfridge HI147-00 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 145-00 User manual

Hanna Instruments

Hanna Instruments HI 145-00 User manual

Hanna Instruments HI 9040 User manual

Hanna Instruments

Hanna Instruments HI 9040 User manual

Popular Thermometer manuals by other brands

Reed Instruments R2330-NIST instruction manual

Reed Instruments

Reed Instruments R2330-NIST instruction manual

Chino TP-S Easy Thermo instruction manual

Chino

Chino TP-S Easy Thermo instruction manual

Zico ZI-9613 operating instructions

Zico

Zico ZI-9613 operating instructions

anko 42965824 user manual

anko

anko 42965824 user manual

Velleman DEM104 user manual

Velleman

Velleman DEM104 user manual

sauermann Si-TT3 user manual

sauermann

sauermann Si-TT3 user manual

Elcometer 214 operating instructions

Elcometer

Elcometer 214 operating instructions

Philips SBCSC550 Instructions for use

Philips

Philips SBCSC550 Instructions for use

Oregon Scientific JTR-168LR user manual

Oregon Scientific

Oregon Scientific JTR-168LR user manual

Optex PT-3S manual

Optex

Optex PT-3S manual

Cuisinart CGWM-070 user manual

Cuisinart

Cuisinart CGWM-070 user manual

Emos E0301 user manual

Emos

Emos E0301 user manual

Medisana 76120 FTN instruction manual

Medisana

Medisana 76120 FTN instruction manual

TFA 14.1504 instruction manual

TFA

TFA 14.1504 instruction manual

Tenmars TM-301 user manual

Tenmars

Tenmars TM-301 user manual

TFA RAY instruction manual

TFA

TFA RAY instruction manual

KYORITSU 5510 instruction manual

KYORITSU

KYORITSU 5510 instruction manual

Omega Engineering CYD218 Series user guide

Omega Engineering

Omega Engineering CYD218 Series user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.