WARRANTY
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION SPECIFICATIONS
Instruction Manual
HI 9043 • HI 9044
Portable Microprocessor
K-Type Thermocouple
Thermometers Remove the instrument from the packing material and exam-
ine it carefully to make sure that no damage has occurred
during shipping. If there is any noticeable damage, notify
your Dealer or the nearest Hanna Office.
Note: Save all packing materials until you are sure that the
instrument functions correctly. Any defective item must
be returned in the original packaging together with
the supplied accessories.
1. Liquid Crystal Display
2. Measuring unit selection key
3. HI/LO values reset key
4. HOLD key
5. ON/OFF key
HI 9043 and HI 9044 are microprocessor-based thermometers
which allow temperature measurements using K-type thermo-
couple probes. The non-linearity of the temperature probe is
linearized by the microprocessor.
Standard features include dual-level LCD for simultaneously
displaying of the highest and lowest measured temperatures,
displayhold,selectablemeasurementunit(°Cor°F)andresolution
which automatically switches from 0.1° to 1° for temperatures
above200°C (400°F).
The meters are also provided with low battery detection and
BEPS (Battery Error Preventing System), which turns the unit
off when the battery is discharged avoiding erroneous read-
ings caused by low battery level.
• HI 9043 is supplied complete with a 9V battery and
instruction manual.
• HI 9044 is supplied complete with HI 766E2 fixed
temperature probe, a 9V battery and instruction manual.
1) Current temperature value
2) HOLD indicator
3) Low Battery indicator
4) Minimum temperature value
5) Maximum temperature value
6) K-type probe indicator
7) Measuring unit, °C or °F
FACTORY RECALIBRATION
All Hanna thermometers have been accurately pre-calibrated
at the factory. It is generally recommended to have all
thermometers recalibrated at least once a year.
For an accurate annual recalibration, contact your dealer or
the nearest Hanna Service Center.
All Hanna Instruments meters are warranted for two years against de-
fects in workmanship and materials when used for their intended purpose
and maintained according to instructions. Sensors and probes are war-
ranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed mainte-
nance are not covered.
If service is required, contact the dealer from whom you purchased the instru-
ment. If under warranty, report the model number, date of purchase, serial
number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer Ser-
vice department, then return the instrument with the Authorization # included
along with shipment costs prepaid. If the repair is not covered by the war-
ranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for com-
plete protection.
(*) Range may be limited by probe. The range of HI 9044
is limited to 900°C/1650°F by the fixed probe.
Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary information
for correct operation. Please read it carefully before using the
meter.
If you need additional technical information, do not hesitate
to e-mail us at [email protected].
These instruments are in compliance with the directives.
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction and
appearance of its products without advance notice.
Range (*)
Resolution
Accuracy
Typical EMC
Deviation
Battery Type
Life
Probe
Environment
Dimensions
Weight
-50.0 to 1350°C
-58.0 to 2462°F
0.1°C (up to 199.9°C) / 1°C (outside)
0.1°F (up to 399.9°F) / 1°F (outside)
±0.2% F.S.
for 1 year, excluding probe error
±3°C / ±6°F
with HI 766 K-Thermocouple probe
1 x 9V (IEC 6LR61) battery
approx. 500 hours of continuous use
HI 766 K-Thermocouple series
• optional for HI 9043
• HI 766E2 fixed for HI 9044
-10 to 50ºC (14 to 122ºF);
RH max 95% non-condensing
180 x 83 x 40 mm (7.1x3.3x1.6")
226 g (8 oz.)
ACCESSORIES
OPERATIONAL GUIDE
INITIAL PREPARATION
Remove the battery cover on the back of the thermometer.
Unwrap the supplied 9V battery, connect it to the battery clip
and reattach the cover.
Connect a K-type thermocouple probe to the meter.
Note: In HI 9044, the probe is fixed.
To switch ON, press the ON/OFF key on
the front of the meter.
The thermometer will carry out a self
diagnostic test routine, the LCD will
show all segments for a few seconds (or
as long as ON/OFF is held), followed
by the percentage indication of the
remaining battery life.
The thermometer then enters normal measurement mode.
If a temperature probe is plugged in, the meter displays the
measured temperature automatically switching to the resolu-
tion suitable to the temperature range; i.e. 0.1° up to
199.9°C (399.9°F), or 1° above.
If no probe is plugged in, or if reading
is over-range, the display shows flash-
ing dashes.
If a measurement is slightly over the range of the meter
specifications, the display flashes the closest full-scale value.
To switch the meter OFF, press the ON/OFF key.
MEASURING SCALE (°C/°F)
Theinstrumentisfactorysettothe°C scale, butmeasurementscan
be performed in either the Celsius or Fahrenheit scale.
Pressthe°C/°Fbuttontoselectthedesired
scale.
HOLD MODE
The HOLD function is activated by press-
ing the HOLD key.
Themeasured temperatureis heldon the
display until HOLD is pressed again.
The "H" tag blinks on the display to
indicate the HOLD mode.
Note: Although the display is frozen, internally the meter
continues measuring and updating Hi and Lo values.
CE DECLARATION OF CONFORMITY
ACCESSORIES
IST9043R1 06/05
HIGH/LOW TEMPERATURES
The maximum and minimum tempera-
tures are continuously monitored and
displayed on the lower portion of the
LCD.
Note: When reading goes over-range, the Hi and Lo values
display dashes until cleared.
CLEAR FUNCTION
Upon pressing the CLEAR key, the
High/Low values may be cleared at
any time during measurement and
the current reading is assigned to the
highest and lowest temperature val-
ues.
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which
they are used.
Operation of these instruments in residential areas could cause unacceptable interference to radio and
TV equipment, requiring the operator to take all necessary steps to correct interference.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC
performance.
To avoid electrical shock, do not use these instruments when voltage at the measurement surface
exceeds 24VAC or 60VDC.
To avoid damage or burns, do not perform any measurement in microwave ovens.
K-TYPE THERMOCOUPLE PROBES
with integral handle, 1 m (3.3’) cable & mini-connector:
HI 766A Roller surface probe, max 320°C/600°F
HI 766B Surface probe, max 650°C/1200°F
HI 766B1 90º Surface probe, max 450°C/840°F
HI 766B2 Spring-loaded,surface probe, max
900°C/1650°F
HI 766B3 Spring-loaded, small surface probe with
insulated shaft, max 200°C/390°F
HI 766C Penetration probe, max 900°C/1650°F
HI 766C1 Ultra-fast penetration probe, max 300°C/
570°F
HI 766D Air probe, max 300°C/570°F
HI 766E1 General purpose probe, max 900°C/1650°F
HI 766E2 General purpose probe, max 900°C/1650°F
HI 766F High temperature, flexible wire probe
without handle, max 1100°C/2000°F
HI 766F1 Flexible wire probe without handle, max
480°C/ 900°F
HI 766TR1 Penetration probe, max 250°C/482°F
HI 766TR2 Penetration long probe, max 250°C/482°F
HI 766TV1 Pipe clamp probe, max 200°C/390°F
with detachable handle & mini-connector (to be used
in conjunction with the HI 766HD probe handle):
HI 766PA Roller surface probe, max 320°C/600°F
HI 766PB Surface probe, max 650°C/1200°F
HI 766PC Penetration probe, max 900°C/1650°F
HI 766PD Air probe, max 300°C/570°F
HI 766PE1 General purpose probe, max 900°C/1650°F
HI 766PE2 General purpose probe, max 900°C/1650°F
grill surface probe:
HI 766B4 Grill surface probe with 70 cm (27.6’’)
cable (protected with stainless steel jacket),
max 250°C/482°F
HI 7664B4S Spare stainless steel sensor for HI766B4 probe
OTHER ACCESSORIES
HI 710009 Shockproof rubber boot, blue
HI 710010 Shockproof rubber boot, orange
HI 710020 Spare protective case
HI 721316 Rugged carrying case
HI 766EX Extension cable for K-type probes
HI 766HD Rugged thermocouple probe handle with
1m (3.3') cable fitted with mini-connector
The instrument is powered by a 9 V battery and is provided
with the Battery Error Prevention System (BEPS), which turns
the unit off when a low battery signal is detected.
When the remaining battery level is
less than 10%, a warning symbol
blinks on the display to indicate a low
battery condition.
It is recommended to replace the battery as soon as the low
battery condition is detected.
Remove the cover on the meter's back by applying pressure in
the indicated direction. Unplug the rundown battery and
replace it with a new one.
Battery replacement must only take place in a non-hazardous
area using a 9V alkaline battery.
BATTERY REPLACEMENT

This manual suits for next models

1

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 92804 User manual

Hanna Instruments

Hanna Instruments HI 92804 User manual

Hanna Instruments Checktemp HI 98501 User manual

Hanna Instruments

Hanna Instruments Checktemp HI 98501 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 93530 User manual

Hanna Instruments

Hanna Instruments HI 93530 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments Checktemp series User manual

Hanna Instruments

Hanna Instruments Checktemp series User manual

Hanna Instruments HI 9063 User manual

Hanna Instruments

Hanna Instruments HI 9063 User manual

Hanna Instruments HI 93551R User manual

Hanna Instruments

Hanna Instruments HI 93551R User manual

Hanna Instruments HI145-00 User manual

Hanna Instruments

Hanna Instruments HI145-00 User manual

Hanna Instruments HI 9040 User manual

Hanna Instruments

Hanna Instruments HI 9040 User manual

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments

Hanna Instruments Pronto Plus HI99551 Series User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments HI 98710 User manual

Hanna Instruments

Hanna Instruments HI 98710 User manual

Hanna Instruments HI98197 User manual

Hanna Instruments

Hanna Instruments HI98197 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments HI 9057 User manual

Hanna Instruments

Hanna Instruments HI 9057 User manual

Hanna Instruments Checktemp 1 User manual

Hanna Instruments

Hanna Instruments Checktemp 1 User manual

Hanna Instruments DiST 7 User manual

Hanna Instruments

Hanna Instruments DiST 7 User manual

Hanna Instruments HI 98121 User manual

Hanna Instruments

Hanna Instruments HI 98121 User manual

Hanna Instruments HI 955501 User manual

Hanna Instruments

Hanna Instruments HI 955501 User manual

Hanna Instruments HI 151-00 User manual

Hanna Instruments

Hanna Instruments HI 151-00 User manual

Hanna Instruments HI 146-00 User manual

Hanna Instruments

Hanna Instruments HI 146-00 User manual

Popular Thermometer manuals by other brands

PHYSITEMP BAT-12 operating manual

PHYSITEMP

PHYSITEMP BAT-12 operating manual

Ea2 BL502 user manual

Ea2

Ea2 BL502 user manual

Diagnosis Diagnostic NC300 Instructions for use

Diagnosis

Diagnosis Diagnostic NC300 Instructions for use

ThermoPro TP-60S instruction manual

ThermoPro

ThermoPro TP-60S instruction manual

Omron Eco Temp Smart manual

Omron

Omron Eco Temp Smart manual

Extech Instruments 42500 user manual

Extech Instruments

Extech Instruments 42500 user manual

General IRT670 user manual

General

General IRT670 user manual

Taylor WeatherGuide 1521 instruction manual

Taylor

Taylor WeatherGuide 1521 instruction manual

ESPERANZA Dr LUCAS DT-8806C manual

ESPERANZA

ESPERANZA Dr LUCAS DT-8806C manual

Microlife MT 550 manual

Microlife

Microlife MT 550 manual

Fricosmos 480816 quick start guide

Fricosmos

Fricosmos 480816 quick start guide

Swiss dr Frei T-20 quick start guide

Swiss

Swiss dr Frei T-20 quick start guide

ADC Adtemp ULTRA 417 Use, care & maintenance

ADC

ADC Adtemp ULTRA 417 Use, care & maintenance

MedSource MS-131000 manual

MedSource

MedSource MS-131000 manual

Safety 1st Accu-Touch 49529 user guide

Safety 1st

Safety 1st Accu-Touch 49529 user guide

TipTemp TRACEABLE 4202 Series instructions

TipTemp

TipTemp TRACEABLE 4202 Series instructions

Ametek Land LANCOM 4 user guide

Ametek Land

Ametek Land LANCOM 4 user guide

SKF TKTL 10 Instructions for use

SKF

SKF TKTL 10 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.