manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Thermometer
  8. •
  9. Hanna Instruments Checktemp HI98501 User manual

Hanna Instruments Checktemp HI98501 User manual

Other Hanna Instruments Thermometer manuals

Hanna Instruments HI 99556 User manual

Hanna Instruments

Hanna Instruments HI 99556 User manual

Hanna Instruments HI 8757 User manual

Hanna Instruments

Hanna Instruments HI 8757 User manual

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments

Hanna Instruments Pool Line HI985394 User manual

Hanna Instruments Checktemp2 User manual

Hanna Instruments

Hanna Instruments Checktemp2 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI 9041 User manual

Hanna Instruments

Hanna Instruments HI 9041 User manual

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments

Hanna Instruments Checktemp1 HI 98510 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 98501-1 User manual

Hanna Instruments

Hanna Instruments HI 98501-1 User manual

Hanna Instruments HI 146-99 User manual

Hanna Instruments

Hanna Instruments HI 146-99 User manual

Hanna Instruments HI 98121 User manual

Hanna Instruments

Hanna Instruments HI 98121 User manual

Hanna Instruments HI145-20 User manual

Hanna Instruments

Hanna Instruments HI145-20 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 98811 User manual

Hanna Instruments

Hanna Instruments HI 98811 User manual

Hanna Instruments HI 935005 User manual

Hanna Instruments

Hanna Instruments HI 935005 User manual

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments

Hanna Instruments Foodcare HI 93501 User manual

Hanna Instruments HI 98701 User manual

Hanna Instruments

Hanna Instruments HI 98701 User manual

Hanna Instruments HI 149-00 User manual

Hanna Instruments

Hanna Instruments HI 149-00 User manual

Hanna Instruments HI 9060 User manual

Hanna Instruments

Hanna Instruments HI 9060 User manual

Hanna Instruments HI145-00 User manual

Hanna Instruments

Hanna Instruments HI145-00 User manual

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments

Hanna Instruments Checktemp Dip HI98539 User manual

Hanna Instruments HI 955501 User manual

Hanna Instruments

Hanna Instruments HI 955501 User manual

Hanna Instruments HI 9063 User manual

Hanna Instruments

Hanna Instruments HI 9063 User manual

Hanna Instruments HI 147-00 User manual

Hanna Instruments

Hanna Instruments HI 147-00 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Hanna Instruments Inc. 584 Park East Drive
Woonsocket, RI 02895
www.hannainst.com
www.hannainst.com
HI98501 (Checktemp®)
Instruction Manual
Thank you!
Thank you for choosing a Hanna Instruments product. Please read
this instruction manual carefully before using the instrument. For
additional information, visit www.hannainst.com or e-mail us at
tech@hannainst.com.
Specifications
Range -50.0 to 150.0 ºC / -58.0 to 302 ºF
Resolution 0.1 ºC (-50.0 to 150.0 ºC)
0.1 ºF (-58.0 to 199.9 ºF) / 1 ºF (above 200 ºF)
Accuracy
±0.2 ºC (-30.0 to 120.0 ºC)
±0.3 ºC (outside: -50.0 to -30.0 ºC and
120.0 to 150.0 ºC)
±0.5 ºF (-22.0 to 199.9 ºF)
±1 ºF (outside: -58.0 to -22.0 ºF
and 200 to 302 ºF)
Environment -30 to 50 ºC (-22 to 122 ºF)
Battery Type CR2032 (1 pc.)
Battery Life approx. 2000 hours of continuous use
Auto Off 8 min (default), 60 min. or OFF
Dimensions 50 x 185 x 21 mm (2 x 7.3 x 0.9“)
Weight 50 g (1.8 oz.)
Certification EN 13485:2001 - Suitability: Storage;
Environment: E; Accuracy Class: 0.5; IP65
Operation
Turn Checktemp®ON with ON/OFF button: all LCD segments are
displayed for 1 second, and CalCheck®starts automatically to verify
that Checktemp®is still accurate to its specifications. A message of
“CAL“ and “-0-“ means that Checktemp®is within specifications and
ready to be used. While measuring temperature, remember that:
• The temperature sensor is located at the tip of the
stainless steel probe.
• It is necessary to wait for a few seconds for the display to stabilize.
Liquid Crystal Display
ON/OFF button
Maximum Immersion Level
Temperature Probe
4 cm
1.5”
Recommended
Immersion Level
EN13485
Storage
E/ 0.5
Battery
Setup
button
Meter Setup
Enter Setup to change the temperature unit (ºC or ºF) or to adjust the
auto shut off time. To enter the Setup MODE, press the SET button
located inside the battery compartment once for temperature unit or
twice for auto shut off.
• Use the ON/OFF button to switch between “ºC” or “ºF”. Press SET
once to save and continue to auto shut off settings.
• Use the ON/OFF button to cycle through the following Auto Shut
Off options: 8 minutes (“d08”, default value), 60 minutes (“d60”),
OFF (“d--”). Press the SET button once to save and continue to
normal operation.
Battery Replacement
Replace the battery when the battery symbol is blinking or when
Checktemp®does not switch on. If the meter has been submerged in
a liquid, make sure it has been completely dried. Check the polarity
of the battery, open the compartment and replace the battery. Close
battery cover.
Note: Batteries should only be replaced in a safe area using the
battery type specified in this instruction manual. Old batteries should
be disposed in accordance with local regulations.
Troubleshooting
Errors that may occur: A message of “CAL” and “Err” means an
internal error has occurred and Checktemp®is not guaranteed to
be within its specifications but may still be operational. If CalCheck®
verifies Checktemp®is still accurate and the display shows “---”
the temperature being measured is out of the specified range or
connection to the probe has been broken. If a message of “Err” occurs
then a calibration data read error has occurred. A message of “Er1”
is caused by an unexpected device reset. A message of “Er2” occurs
if internally a temperature measurement malfunctions. After these
messages occur it is possible to be fixed by a reset. Turn Checktemp®
OFF and then ON with the ON/OFF button to reset. If the error message
continues to show, please contact your local Hanna Instruments Office.
Warranty
Checktemp®is guaranteed for a period of one year after date of
purchase against defects in workmanship and materials when
used for their intended purpose and maintained according to
instructions. This warranty is limited to repair or replacement free
of charge. Damage due to accidents, misuse, tampering or lack of
prescribed maintenance is not covered. If service is required,
contact your local Hanna Instruments Office. If under warranty, report
the model number, date of purchase, serial number and the nature
of problem. If the repair is not covered by the warranty, you will be
notified of the charges incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned Goods Authorization
number from the Technical Service department and then send it with
shipping costs prepaid. When shipping any instrument, make sure it is
properly packed for complete protection.
Recommendations for Users
Before using Hanna Instruments products, make sure that they are
entirely suitable for your specific application and for the environment
in which they are used. Any variation introduced by the user to the
supplied equipment may degrade the meter's performance. To avoid
damages or burns, do not put the meter in microwave oven. For yours
and the meter's safety do not use or store the meter in hazardous
environments.
All rights are reserved. Reproduction in whole or in part is prohibited without the
written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode
Island, 02895, USA. IST98501 06/18