6 7
FIG 14
WATER AND ELECTRICAL CONNECTIONS
1. Remove the red caps from the Inlet and Outlet plus white grommets.
YOUR HEATRAE SADIA TAP PACK INCLUDES A SPLASH SHIELD ASSEMBLY
WHICH MUST BE FITTED. Connect the white plastic nuts to the Inlet and
Outlet bosses. DO NOT OVERTIGHTEN.
Connections from the heater to the tap set must be via the compression
nuts on the Splash Shield Assembly. Refer to the Tap Pack instructions
for details. If necessary use only PTFE tape, NEVER USE PLUMBER’S PASTE.
2. If using the cable grip, remove the red plug, insert the cable and nip
up the outer clamp nut.
3. Make connections to the terminal block: red or brown to L; black or
blue to N; green/yellow to E.
FINAL ASSEMBLY AND TESTING
WARNING: BEFORE SWITCHING ON, ENSURE HEATER IS FULL OF WATER.
1. CHECK EARTH POST ON ELEMENT PLATE IS IN 12 O’CLOCK POSITION.
2. CHECK WATER INLET IS ON RIGHT HAND SIDE.
3. CHECK THERMOSTAT CAPILLARY IS HELD IN POSITION AND DOES NOT
TOUCH ELEMENT TERMINALS.
4. Please leave warning label attached for future reference.
5. The drainage slot in the centre of the backplate lower edge must be
opened by removing the adhesive tape covering it. The slot in the centre of
the backplate top edge must be closed by affixing the adhesive tape provided
over the slot. See FIGs 2 and 6 for location of drainage slots.
6. Turn on the water and fill until water flows freely from the Outlet. With the
hot tap fully open, adjust the flow restrictor as specified on page 2. Turn off
the flow.
7. Check for leaks and refit covers and securing screws ensuring splash
shield assembly is correctly located.
8. Set the thermostat in mid position, switch on the power. Water in the container
will expand during heating causing the tap to drip. THE OWNER SHOULD BE
MADE AWARE OF THIS to avoid erroneous complaints about leaky taps.
SYMPTOM POSSIBLE CAUSE REMEDY
No hot water No water in heater Fill as detailed on page 5 or 6
Blown cut-out or open Replace cut-out or element and check water
circuit element heater is filled with water before switching on
Faulty thermostat Replace thermostat
Heater installed incorrectly Check fitting instruction followed fully
No water when valve turned on Blockage in valve or vented tap Dismantle and clean as necessary
Insufficient mains pressure Check for minimum water pressure (See page 3 )
Excessive expansion of tank Too much back pressure Fit flow reducing valve and adjust flow rate as
detailed on page 2
Water too hot Faulty thermostat Replace thermostat
Element fitted incorrectly Check element is in correct position for the
particular mounting mode. Earth post must
always be in 12 o’clock position
Any problems which cannot be solved using the above chart should be directed to the Service Department at
Heatrae Sadia.
FAULT FINDING
SPARES
CODE DESCRIPTION CODE DESCRIPTION
95604200 Spout 12’’ Chrome plus Gaiter 95608784 Inner Container 7lt
95604656 Telescopic Spout 95608785 Inner Container 10lt
95604659 12’’ Light Grey Spout (Domestic) 95608786 Outercase 7lt
95605445 Thermostat Knob 95608789 Bottom Moulding - white
95605446 On/Off Knob 95611711 EP Gasket (Pk 10)
95606758 EPA 1kW 95612512 Thermostat
95606759 EPA 3kW 95612514 Printed Circuit Board
95607852 Foam Insulation 7lt 95612515 Thermostat Locking Pin
95607853 Foam Insulation 10lt 95612516 Wiring Set
USER INFORMATION
IT IS NORMAL FOR THE TAP OR SPOUT TO DRIP DURING HEATING AS
STREAMLINE IS AN OPEN OUTLET HEATER.
CONTROLS
When used Oversink, the heater has 2 controls: flow and temperature
setting (see page 3 for temperature options available).
TEMPERATURE CONTROL
Temperature at minimum setting ideal
for freezing protection. Move control
anticlockwise for maximum setting.
DESCALING
In hard water areas, minerals build up
on the element and in the bottom of the container, around the outlet. When this
happens, there will be gradual fall off in flow. To descale, proceed as follows:
Isolate electricity supply and turn off water. Remove both covers. Drain the heatre
through the appropriate boss.
OVERSINK MODE
Remove blank plug at the top left of heater. The outlet standpipe is now visible. Clean out the cross hole using a pipe
cleaner or similar device. Check sealing washer in blank plug and re-seal. If in any doubt over the seal, replace with a
new one. Remove element plate and inspect element. If scaled, clean carefully by hand. DO NOT USE POINTED INSTRUMENT.
Do not use de-scaling fluids.
UNDERSINK MODE
Remove oulet pipe from water heater. The outlet fitting will then be visible. Proceed as for Oversink.
Fig 15 - Oversink model as normally supplied
FIG 16
GUARANTEE
Goods are guaranteed and sold subject to our standard conditions of sale. A copy of these conditions will be
supplied on application. In the event of the unit being returned under the terms of guarantee, it should be
despatched direct to your supplier and not to Heatrae Sadia Heating.
This guarantee does not affect the statutory rights of the consumer.
WARNING: THIS HEATER IS
NOT
GUARANTEED AGAINST DAMAGE BY FROST.
Earth Post at
12 o’clock
position