HEINRICH DNM User manual

PUBLIC ADDRESS SYSTEM
ENVIRONMENTAL NOISE DETECTION PROBE
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
DNM
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
1

PUBLIC ADDRESS SYSTEM
1. SAFETY PRECAUTIONS ...................................................................................................................................................................3
2. FEATURES .....................................................................................................................................................................................................5
3. PRODUCT FUNCTION INTRODUCTION........................................................................................................................................... 5
4.OPERATION INSTRUCTION............................................................................................................................................................. 6
5.REAR PANEL CONNECTIONS......................................................................................................................................................... 7
6. CONNECTION DIAGRAM............................................................................................................................................................... 8
7. SPECIFICATIONS....................................................................................................................................................................................... 9
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
2

PUBLIC ADDRESS SYSTEM
SAFETY PRECAUTIONS
Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the
conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you
keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which
could result from mishandling. Before operating your product, read this manual rst and understand the safety symbols and
messages so you are thoroughly aware of the potential safety
When Installing the Unit
Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result
in re or electric shock.
Use the unit only with the voltage specied on the unit. Using a voltage higher than that which is
specied may result in re or electric shock.
Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proxim-
ity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in re or
electric shock.
Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker
terminals, never touch these terminals to avoid electric shock.
Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic
disaster may result.
Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result
in the unit falling down, causing personal injury and/or property damage.
When the Unit is in Use
Should the following irregularity be found during use, immediately switch o the power, disconnect the power supply plug
from the AC outlet and contact your nearest dealer. Make no further attempt to operate the unit in this condition as this may
cause re or electric shock.
If you detect smoke or a strange smell coming from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
3

PUBLIC ADDRESS SYSTEM
SAFETY PRECAUTIONS
When Installing the Unit
Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.
When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the
unit with a damaged power supply cord may cause a re or electric shock.
When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord
connected to the outlet may cause damage to the power cord, resulting in re or electric shock. When removing the power
cord, be sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in re.
Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations
generating sooty smoke or steam as doing otherwise may result in re or electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property
damage. In addition, the object itself may fall o and cause injury and/or damage.
Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume
when power is switched on can impair hearing.
Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which
in turn can cause heat to generate and result in a re.
Contact your dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a re or damage
to the unit may result. HEINRICH If dust accumulates on the power supply plug or in the wall AC outlet, a re may result. Clean
it periodically. In addition, insert the plug in the wall outlet securely.
Switch o the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the
unit unused for 10 days or more. Doing otherwise may cause a re or electric shock.
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
4

1. Communications input terminals
1. GND (Black wire)
2. Communications wire (White wire)
3. 24V DC power wire (Red wire)
PUBLIC ADDRESS SYSTEM
FEATURES
1.The detection probes could be connected in series as well as in parallel. And every digital detection could connect no more
than 16 probes.
2.You can customize the sampling frequency period.
3. Collecting the environment noise and processing the signal before sending it to the detection host.
4. The digital noise collected probe.
5. Cascade function: one line input and one line output.
6. Adjustable function of high and low ltering frequency.
7. The furthest distance of transmit is about 3 kilometers.
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W: www.heinrichlimited.com E: [email protected]
5

PUBLIC ADDRESS SYSTEM
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
2. Monitor output terminal
1. GND (Black wire)
2. Communications wire (White wire)
3. 24V DC power wire (Red wire)
1. Connecting the system according to the correct connection diagram and check carefully
2. whether the output connecting or input connecting is short circuit.
3. Check whether the operation manual conforms to the local grid.
4. Open the computer software, turn on the power and the active amplier, after setting the conguration correctly then
connect the probe.
Dial the code switch address in binary system setting 1-16.
Dial the code switch address from left to right (1-4) in binary system setting 1-16
0000(represents 1)、1000(represents 2)、0100(represents 3)、1100(represents 4)、
0010(represents 5)、1010(represents 6)、0110(represents 7)、1110(represents 8)、
0001(represents 9)、1001(represents 10)、0101(represents 11)、1101(represents 12)、
0011(represents 13)、1011(represents 14)、0111(represents 15)、1111(represents 16).
6

PUBLIC ADDRESS SYSTEM
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
REAR PANEL CONNECTIONS
7

PUBLIC ADDRESS SYSTEM
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
CONNECTION DIAGRAM
8

PUBLIC ADDRESS SYSTEM
HEINRICH HEINRICH LIMITED, 69 Athlone Road London SW22DU
W : www.heinrichlimited.com E: [email protected]
Model DNM
MIC Condenser
Communica�on Method Single wire system general line method
The noise frequency filter 4 sets
Monitor output 1V/600Ω
Frequency Response 80-18KHz(+1/-3dB )
THD ≤0.1%
Power Consump�on ≤1W
Transmit Distance 3KM
Power Supply DC 24V
Size(mm)185x275x105
Weight 0.86Kg
SPECIFICATION:
9
Table of contents
Popular Measuring Instrument manuals by other brands

Kamstrup
Kamstrup MULTICAL 402 Installation and user guide

SubSurface Instruments
SubSurface Instruments LC-5000 Simple operation manual

ProZyme
ProZyme Gly-Q user manual

MG
MG MG800S instructions

Panasonic
Panasonic DMR-HW220 operating instructions

Hanna Instruments
Hanna Instruments HI96786C instruction manual