OPERATING INSTRUCTIONS
Program Controller RT100D

112
Program Controller RT100D
Contens
page
Introduction . . . . . . . . . . . . . . 3
2. First Start . . . . . . . . . . . . . . . 4
3. Description of the face
3.1 Using of fixed programs . . . . . . . . . 5
3.2 Program Adjustment . . . . . . . . . . 7
4. Use of Program Datas . . . . . . . . . . . . . 8
5. Error Messages . . . . . . . . . . . . . . 9
6. Technical Datas . . . . . . . . . . . . . . 11
Notiz

310
Program Controller RT100D
1. Introduction
The controller RT100D is used for controlling of electrical kilns for ceramics
and glas fireing.
The RT100D is able to control exactly the temperature and temperature
rate in a fireing process. Nine fixed programs are helpful for using this con-
trol unit. This programs can be adjusted individually. With this fixed pro-
grams the base of adjustment is already done for you.
Programdatas and values can be checked every time and set into the pro-
gram memory.
The control unit will be delivered with a wall pocket. For programming work
you can move the controller out of this pocket and if programming is done
you can put it back into the pocket. This feature makes it very easy to han-
dle the control unit.
IMPORTANT: It is not allowed to put the control unit
on the top of the kiln during fireing.
Every control unit RT100D is tested and checked for 100% of quality in our
company .
All our control units have an overheating safety relay ,but if you use the
control units you should observe the fireing .
Do not fire the kiln without observing.
If you have any problems please have a look into the error list at the end of
this manual.
If you are not able to solve your problems by yourself, please contact your
sales department.
6.0 Technical Datas
* Using a Harting 7D connector the Pin-No. are not defined
Powerline 200 bis 250Volt 50 / 60Hz
Fuse 0,04 A T
Power consumption 2 VA
Output 2 Relais n.o.
230 V max. 4 A
Imput Thermocouple Typ R
Pt10Rh / Pt
Solution 1 °C
Display 0,3 % +/- 1 Digit
Dimension 200 * 100 * 45 mm
Weight 0,6 kg
Ambient temperature 0 bis 50 °C
wire
No.
AMP
Pin-No.
Harting 7D
Pin-No.
Harting
15D
Pin-No.
Function
+ red
-white
1
2
3
4
B5
C5
Thermocouple Platin
+ green
-white
11
12
*
B5
A5
Thermocouple Nickel
1 8 5 A1 Input L1
2 9 2 B1 Input N
3 13 6 A3 Output heating
4 14 1 B3 Output N
7 7 7 C3 Output safety relay

94
Program Controller RT100D
2. First Start
The control unit has a plug for the connection with the kiln. This plug is safe
against wrong connection and it fits only in one position.
At the buttom side of the RT100D you find the main switch, please switch control
unit on and wait for the display.( app. 3 sec.). Now you can read the kiln tempera-
ture on the display and you are able to program the control unit.
5.0 Error Messages
The control unit can check a lot of functions by itselfs. If the control unit may find any mistake, the kiln
will be switched off and the display shows a faulty number:
Display: F1
During the full power periode the controller checks the rise of the kiln temperature , it must be more
than 1°C in 20 Minutes. If the kiln is to slow the control unit shows F1.
causes:
- heating element is faulty or to old
- with 3 Phase Systems: on Phase is missing
- Thermocouple is short connected.
- door switch is not closed
Display: F2
Is the heating time in the full power periode longer than 18 hours the kiln will switched off and the
display shows F2.
causes:
- heating element is faulty or to old
- with 3 Phase Systems: on Phase is missing
Display: F3
If the measurement from the thermocouple is too high the controller shows F3.
causes:
- Thermocouple faulty
- wire to thermocouple faulty
Display: F4
If the measurement from the thermocouple is negative the controller shows F4.
causes:
- thermocouple wrong connected
- wire to thermocouple wrong connected
Display: F5 or F6
Internal System Error.
Display: F7
If the kiln temperature is higher than 20°C over the top temperature and takes this problem longer
than five minutes the control unit switch te kiln off and shows F7.
causes:
- rela
y
in the kiln is fault
y

58
Program Controller RT100D
3. Description of the face
3.1 Using of fixed programs
The control unit RT100D will be delivered with 9 fixed programs all this
programs can be adjusted by the customer.
The following switches should be pressed to start a fixed program.
Prog
sichern
Prog
°C
h:m
Tem p 2
Tem p 1
Zeit 3Zei t 2Zeit 1 End e
Digital -Display
top-temperature
first temperature
fixed programs
choose of
time and temp
start/stop program
set program to memory
values up
values down
temperature in °C
time in hours : minutes
main switch
fuse
4.0 Use of Program Datas
A
fter you have pressed the start switch the control unit will start the program .
The first point of working is the delay time.After you have programmed the delay time
the controller wait till this time is zero. On the display you will see the value of the
delay time.
The control unit starts the fireing program as soon as the delay time reached zero.
This feature will be used if you like to start a kiln e.g. in the evening.
The fire-process beginns with the ramp time. The control unit calculats the right
heating power to bring the kiln slowly to the firtst set point during the ramp time. If the
ramp time reached zero the kiln will be fired with full power. If the kiln temperature
reached the top temperature the control unit soak during the soak time.
A
fter the soak time the controller switchs the kiln of and the kiln temperature will cool
down.

76
Program Controller RT100D
switch: Prog
switch:
please press this switch a few times ,
if you get the right program number on
the display please stop pressing the key.
switch: start/stop
Program will start
Here you find the list of the fixed programs:
Programm No: 7 - 9 are all zero.
Descprition:
All time values are in hours and minutes.
0h30 = 0 hours and 30 minutes
Zeit 1: delay time
Zeit 2: ramptime
Temp 1: first set point
Temp 2: top temperature
Zeit 3: soak time
Programm
Nr.
1 2 3 4 5 6
P1 P2 P3 P4 P5 P6
Zeit 1 0h 00 0h 00 0h 00 0h 00 0h 00 0h 00
Zeit 2 4h00 5h 00 7h 00 10h 00 3h 00 4h 00
Temp 1 500°C 500°C 500°C 930°C 400°C 400°C
Temp 2 1230°C 1230°C 1230°C 1230°C 800°C 800°C
Zeit 3 0h 30 1h 00 1h 00 1h 00 0h 30 1h 00
3.2 Program Adjustment
If you like to adjust program datas you should use the following description:
Please load and start your programm ( see section 3.1) and press the following switches:
switch: start/stop
switch: ⇒
please press this switch a few times if the
right data is displayed stop pressing.
switch: ⇑or ⇓
to adjust values
If you have changed all datas like you wish, you can start your programm with the start/stop switch.
switch: start/stop
This adjustment that you have made will only used for the present fireing. If you like to store this datas
into the memory, please use the following way:
switch: set Prog
switch: start/stop
Important:
The delay time can not be stored in memory.
Table of contents
Popular Controllers manuals by other brands

Brodersen
Brodersen RTU32R Installation and wiring guide

GARDASOFT
GARDASOFT TR-CL Series user manual

Juniper
Juniper C series Hardware guide

Powerhouse Dynamics
Powerhouse Dynamics SiteSage installation guide

Dynamic
Dynamic RHINO2 DS90 installation manual

Fright Ideas
Fright Ideas BooBox FlexMax quick start guide

Danfoss
Danfoss ADAP-KOOL AK-HP 780 Design guide

Comunello
Comunello RAYWIN R60 instruction manual

WEG
WEG AVR-A-OPT-06 Installation, operation and maintenance manual

AIC Wireless
AIC Wireless Aurora-AX Sedona AUR-WIO-4DI installation instructions

Argus
Argus Cordex CXC Setup

Nitto Seiko
Nitto Seiko HC100 Operation manual