HES Assa Abloy RF5010 User manual

®RF5010 and RF5210
Installation Instructions
Product
Applications
Electrical
Cable detail
Certifications
Warranty
Description
Dimensions
Orientation
Compatibility
Access Control Systems
Proximity Cards
Frequency
Indicators
Supervision
Integrated Electric Strike and Proximity Card Reader
See pages 4-6
Non handed
Open Architecture
Interfaces with Wiegand Protocol Systems
Supports HID 26 39 Bit Formats
Supports HID 125 kHz Credentials
Red/Green LED and Buzzer
Door Position Switch and Latchbolt Monitor
Frames
Trim Enhancer
Locks
Latchbolts Released*
Environment
Temperature
Humidity
Steel, Aluminum, Wood
Included
Cylindrical
RF5010: Accomodates up to 5/8" Latchbolt
RF5210: Accomodates up to 3/4" Latchbolt
Not Recommended for Outdoor use
32 F 150 F (0 C 65 C)
5 95%, Non-condensing
Reader Module
Distance to Host
Recommended Type
Electric Strike Module
Distance to Power
Recommended Type
500 ft. Max.
18 22 AWG (Dependent on Distance) Stranded and Shielded
See Page 3
See Page 3
Compliance
Security
FCC Part 15/IC Class B
ANSI/BHMA 156.31, Grade 1
Lifetime Waranty against defects
in materials and workmanship
RF5010 and RF5210: INTERNAL ANTENNA
HES, Inc.
22630 N. 17th Ave.
Phoenix, AZ 85027
800-626-7590
Reader Module
Operating Voltage 12VDC +/- 20%
Operating Current
Electric Strike Module
Operating Voltage 12VDC +/- 10%
Operating Current 240 mA max. @ 12VDC
HID is a registered trademark of HID Corporation.
1
*Faceplate options accommodate
various keeper and latchbolt
actions. For more detail, contact
HES tech support
at 800-626-7590
125 mA Max. @ 12VDC


RF5010 and RF5210: INTERNAL ANTENNA
Installation Directions
1. Prepare door jamb for hybrid electric strike per the appropriate
template detail (see pages 4-6). Be sure to allow enough room
behind the strike in the cutout to avoid pinching any wires.
2. Drill a 3/8” hole for the door position switch per the appropriate
template detail (see pages 4-6). Note that the door position switch
may be positioned as desired, within limits of its 10” connector. If
necessary (e.g. wood frames), drill a channel from the door position
switch to hybrid electric strike to accommodate the 10“ cable.
Next, drill a matching 3/8” hole in the door and install the press-fit
magnet so that it will contact with the door position switch.
3. If applicable (e.g. aluminum frames),install mounting tabs (sold
separately as P/N 152), using #10-32 screws.
4.Verify that the strike is in the correct mode of operation. This unit
ships in fail secure mode. If you need to convert to fail safe,
see page 7.
5. Check that the wires running from the host control panel and/or
power supply are correct for the components and distance (see
Wiring Diagram on page 2 and Wire Gauge Diagram below).
Connect the three pigtails provided (8 pin, white 2 pin and black 2
pin) to these wires and apply grease as needed. connect the three
pigtails to the hybrid electric strike. Note: It doesn’t matter which
2 pin connector is used. When power is connected, the hybrid
electric strike will automatically run the initialization/self test
described in step 14.
6. Connect and mount the door position switch, routing its 10”
cable from the door position switch to the hybrid electric strike.
7. Plug the loose end of the door position switch cable into its 2
pin connector on the bottom of the hybrid electric strike and apply
grease as needed.
8. Connect the wire bundle on the side of the hybrid electric strike
to the pigtails/wire back to the host control panel. Check any
pertinent information from the access control system installation
guide or manual.
Prepare Frame
9. Attach the faceplate to the hybrid electric strike, using the #8-32
screws provided.
10. Install the trim enhancer on the hybrid electric strike (if needed
to cover any extra space).
11. Install the hybrid electric strike in jamb cutout, using #12-24
screws provided (or wood screws where necessary).
12. If needed, see page 8 to make horizontal adjustments in frame
(RF5210 only).
13. If applicable, tighten the #10-32 screws holding the mounting
tabs.
Finish Installing
14. When power is supplied to the hybrid electric strike, the LED will
flash green three times, while the beeper simultaneously beeps. The
LED will then turn red. This sequence indicates that the micro-
controller is operating properly.
15. Present a Proximity ID card to the reader. The LED will turn green,
while the beeper beeps once. This indicates that the card was read
successfully.
16. Simultaneously, the keeper will click open. This indicates that
communication between the host and the hybrid electric strike is
operational.
17. For further testing of communication with the host, consult the
manual for the host control panel or the site’s system administrator.
Testing and Operation
Connect Components and Wiring
Wire Gauge Diagram
Max. One-way Distance Voltage Drop/100’ Recommended AWG
800’
500’
300’
200’
120’
100’ or less
12VDC @ 240 mA
0.15
0.24
0.38
0.61
0.97
1.53
12 Gauge
14 Gauge
16 Gauge
18 Gauge
20 Gauge
22 Gauge
3
CAUTION! Before connecting any device at the installation site, verify that there is 12VDC input voltage using a multimeter.
Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage outside the electrical
specifications outlined on page 1 may cause severe damage to the unit and will void the warranty. Also note that a linear
power supply is recommended. Finally, this product contains electrostatic sensitive components. We recommend proper
grounding techniques be observed during installation.

1-1/4” x 4-7/8” Square Corner Faceplate
ANSI Metal Jamb Installations
RF5010 or RF5210 with 501 Faceplate
1-1/4” x 4-7/8” Radius Corner Faceplate
Aluminum Jamb Installations
RF5010 or RF5210 with 501-A Faceplate
Cutout Template
RF5010 and RF5210: INTERNAL ANTENNA
4
32
1 - 1/4”
86
3 - 3/8”
10
3/8”
4 - 7/8” 124
4 - 1/8” 105
1 - 1/4” 32
3 - 3/8” 86
R- 5/32” 4
4 - 1/8” 105
4 - 7/8” 124
3/8” 10
RF5010:
RF5210: 1 - 13/16”
1 - 11/16” 43
47
RF5010:
RF5210: 1 - 13/16”
1 - 11/16” 43
47

Cutout Template
RF5010 and RF5210: INTERNAL ANTENNA
Remove additional material as
needed to provide clearance for
hybrid electric strike and wires

Corner
Cutout Template
RF5010 and RF5210: INTERNAL ANTENNA
6
3/8” 10
10” 254
3 - 3/8”
RF5010:
RF5210: 1 - 13/16”
86
1 - 11/16” 43
5/32” 41/8” 3
1 - 3/8” 35
47
R-
Remove additional material as
needed to provide clearance for
hybrid electric strike and wires

Fail Safe Conversion
RF5010 and RF5210: INTERNAL ANTENNA
7
a. In order to change the mode of operation from fail secure
(standard) to fail safe, first detach the reader module by removing
the two screws on the back of the hybrid electric strike.
Remove Reader Module
b. Loosen the two #2-56 screws located on the back of the
strike module, as shown above, but do not remove them.
c. Move screws from the top of the hole to fail safe position.
d. Tighten screws.
Convert Mode
e. Replace the reader module and tighten the two
screws to hold it in place.
Finish
a
cFail Safe
B

®RF5010 and RF5210
Installation Instructions
Product
Applications
Electrical
Cable detail
Certifications
Warranty
Description
Dimensions
Orientation
Compatibility
Access Control Systems
Proximity Cards
Frequency
Indicators
Supervision
Integrated Electric Strike and Proximity Card Reader
See pages 4-6
Non handed
Open Architecture
Interfaces with Wiegand Protocol Systems
Supports HID 26 39 Bit Formats
Supports HID 125 kHz Credentials
Red/Green LED and Buzzer
Door Position Switch and Latchbolt Monitor
Frames
Trim Enhancer
Locks
Latchbolts Released*
Environment
Temperature
Humidity
Steel, Aluminum, Wood
Included
Cylindrical
RF5010: Accomodates up to 5/8" Latchbolt
RF5210: Accomodates up to 3/4" Latchbolt
Not Recommended for Outdoor use
32 F 150 F (0 C 65 C)
5 95%, Non-condensing
Reader Module
Distance to Host
Recommended Type
Electric Strike Module
Distance to Power
Recommended Type
500 ft. Max.
18 22 AWG (Dependent on Distance) Stranded and Shielded
See Page 3
See Page 3
Compliance
Security
FCC Part 15/IC Class B
ANSI/BHMA 156.31, Grade 1
Lifetime Waranty against defects
in materials and workmanship
RF5010 and RF5210: INTERNAL ANTENNA
HES, Inc.
22630 N. 17th Ave.
Phoenix, AZ 85027
800-626-7590
Reader Module
Operating Voltage 12VDC +/- 20%
Operating Current
Electric Strike Module
Operating Voltage 12VDC +/- 10%
Operating Current 240 mA max. @ 12VDC