Hiwin LA Series User manual

Linear Actuator
User Manual
www.hiwinmikro.tw

MA99UE17-1804
1
CONTENTS
Important Notes and Operating Safety Regulation:
Chapter 1 LinearActuator LASeries User's Guide
1. Product Specification and Operation Environment………………………………………………………………P6
2. Installation Guide…………………………………………………………………………………………….………P8
3. Caution Notice………………………………………………………………………………………………………..P10
4. LinearActuator with Quick-Release User's Guide……………………………………………………………..…P11
Chapter 2 LAK Series Controller User's Guide
1. Product Specification and Operation Environment……………………………………………………………….P13
2. System Overview……………………………………………………………………………………………………..P16
3. Installation Guide……………………………………………………………………………………………………..P20
4. Basic Operation Guide……………………………………………………………………………………………….P24
5. Caution Notice………………………………………………………………………………………………………...P26
6. LAKC1-1 Over Current Protection Box……………………………………………………………………………..P26
Chapter 3 Sealed Lead Acid Batteries User's Guide
1. Battery Specification…………………………………………………………………………………………………P28
2. Battery Power Depletion Chart……………………………………………………………………………………...P28
3. Battery Charging Guide………………………………………………………………………………………………P28
4. Installation of Battery on Controller………………………………………………………………………………….P30
5. Battery Notice………………………………………………………………………………………………………….P31
Chapter 4 LA Series Products Wiring & Installation
1. LinearActuator Motor Wiring…………………………………………………………………………………………P32
2. Reed Switch Specification &Application Circuitry…………………………………………………………………P34
3. PLC Examples…………………………………………………………………………………………………………P35
4. Positioning Feedback Device Wiring………………………………………………………………………………..P36
Chapter 5 LAK\LAP Wiring & Installation
1. LAP1/LAP2 Wiring…………………………………………………………………………………………………….P43
2. LAP3 Wiring……………………………………………………………………………………………………...…….P45
3. LAP3N Wiring…………………………………………………………………………………………………………..P46
4. LAP4G Wiring…………………………………………………………………………………………………………..P47
5. LAP4N/LAP4M/LAP4R Wiring………………………………………………………………………………………..P48
6. LAP5 Wiring…………………………………………………………………………………………………………….P49
7. Connector Drawings……………………………………………………………………………………………………P51

MA99UE17-1804
2
Chapter 6 Appendix
1. Label Description…………………………………………………………………………………………………….P52
2. IP rank Description…………………………………………………………………………………………………..P53
Chapter 7 Product use in Medical Bed
Chapter 8 Product EMC Information
1. Product EMC Information…………………………………………………………………………………………….P62
2. Declaration of Conformity For EN 60601-1-2………………………………………………………………………P63
*The contents of this user`s manual are subject to change without notice. If you are experiencing any technical
difficulties or do not understand the contents of this manual, please contact our technical representative or local
distributors for assistance.

MA99UE17-1804
3
Important Notes:
1. Please carefully read this operation manual before using this product. We don't take responsibility for any damage,
accident or injury possibly caused by those who didn't follow these notes to install.
2. Don't disassemble or reinstall this product yourself. Since this product is designed under structural operation,
computer simulation or physical test, it can't be disassembled or reinstalled without specialist's permission. If there is
any accident or damage caused by self disassembly or reinstallation, we will not take responsibility.
3. If the appearance is damaged before installing or using, please immediately contact us or an agent.
4. Ensure to read product label or performance specifications indicated by the delivery document before installing linear
actuators.
5. Carefully read power supply indicated on the specification label of a control box before using this product.
Moreover, confirm the supplied power complies with product requirement. If there is product damage or personnel
injury caused by wrong supplied power, we will not take responsibility.
6. Don't use this product under an environment over the rating load. If there is any damage or injury, we will not take
responsibility.
7. Don't use this product under an impact environment. If there is product damage, accident or injury, we will not take
responsibility.
8. Don't handle this product yourself if faults occur. This product can be repaired by our qualified technicians only.
9. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
10. Children should be supervised to ensure that they do not play with the appliance.
11. Do not pull the power cable with excessive force when moving the product.
One-year guarantee is provided since the date this product delivered. For product damage caused by the improper
operations (Please refer to notes and installations in this operation manual.) or natural disasters during this period, we
will not take responsibility to replace and maintain them for free.
Operating Safety Regulation:
1. While operating an actuator, don't interrupt the motor operation to avoid failures in motor or mechanical structure.
2. Please follow the directions and use the nominal voltage of actuator motor with DC voltage. The supplied DC voltage
can provide the maximum current at the maximum load.
3. If customers use power supplies and controllers themselves, please follow the current allowed for wire cross-section to
install over current protectors (such as fuse), on the output end of power supplier or the input end of actuator power and
use this over current signal to control actuators, which not only stop movement or disconnect power supply but also
ensure the extension tube of an actuator at the limit position or under the overload operation can disconnect the power
and provide appropriate control and protection.
4. Unless specially customized, the duty cycle of our actuator should be 10%. The duty cycle is defined to continuously
operate 2 minutes and pause 18 minutes. If customers operate over duty cycle (10%), please install overheat detection
and prevention devices (as a fan) and use this overheat detection signal to control actuators to stop movement or
disconnect power supply according to control requirements.

MA99UE17-1804
4
5. If customers don't purchase limit switches, please install the limit switches at the stroke positions of the extension tube
of an actuator yourself and combine that limiter for power failure on controllers and power suppliers to ensure the
power can be disconnected when the extension tube of an actuator moves to the stroke and wire position.
6. The actuator is DC driven. When the two input wires of motor power are exchanged, the extension tube of the
actuator will reversely move. Please use proper controllers and power suppliers while stop. Two input wires of motor
power are short-circuited to provide auxiliary brake. Note that the power of actuator motor should be disconnected
and then short-circuited to avoid short circuit on power supplier.
7. Don't operate up to the stroke limit if there are no limit switches and controllers have no overload protection.
8. Don't apply actuators over the maximum load indicated by the specifications.
9. If the actuator isn't water-proof, please follow the water-proof regulations.
10. Controller power: AC100/110/120/220/230V[50/60Hz] ; the required input power is shown on the controller's
specification tag.
11. Operating temperature: +5°C ~ +40°C (+41°F ~ +104°F).
12. Type of protection of applied parts against electric shock is BF and B.
13. The temperature of Products under storage and transmission is -10℃~+50℃.
14. The clean method of product:Alcoho l(70%).
15. The procedure of the broken product:Recycle by local rules.
16. The product should be installed in a safe place where is allowed to take off the plug easily in an emergency situation.
17. Cycle of inspection (every six months).
18. The hospital bed cleaning procedure must depend on actuator water-proof level while actuator has assembled with
hospital bed.
19. The temperature of Products under storage and transmission is -10~+50℃and it need to be stored in no wet, no dust,
no corrosion gas or liquid environment.
20. If client need to adjust the location of external limit, please make mark on original spot (drawing line with pen、sticker
gluing etc.) to prevent linear actuator get damaged.
21. The specification of the external limit please refer to approved drawing and guidebook.

MA99UE17-1804
5
WARNING:Do not modify this equipment without authorization of the manufacturer.
WARNING:If this equipment is modified, appropriate inspection and testing must be conducted to ensure continued
safe use of the equipment.
WARNING: Read all warnings.
WARNING: Read this manual and follow it carefully before using the device.
WARNING: Remove the power supply cord when the unit is being moved to avoid damage to the power supply cord.
WARNING: Do not use the unit in the presence of flammable anesthetics or other flammable substances in combination
with air, oxygen-enriched environment, or nitrous oxide.
WARNING: Keep children away from the device.
WARNING: Before cleaning, turn off the unit and disconnect the power supply cord from theAC power supply.
WARNING: Always ensure that the supply voltage meets the factory set voltage and frequency range, as provided on
the equipment.
Complete user manual can be obtained from the HIWIN
website: www.hiwinmikro.tw
*Use the manual are subject to change without notice.

MA99UE17-1804
6
Chapter 1 Linear Actuator LA Series User's Guide
1. Product Specification
1.1 Standard Performance:
TYPE
Max.
Push Force
(N)
Max.
Pull Force
(N)
Max. Cyrrent(A)
Max Holing
Force (N)
Speed
(mm/s)
12VDC
24VDC
LAM1-1
4000
3000
12
6
4000
8-11
LAM1-2
2000
2000
12
6
1200
16-21
LAM1-1A
3000
3000
12
6
3000
8-11
LAM2-1
3500
3500
8
4
3000
2-3.5
LAM2-2
2500
2500
8
4
2000
3-6
LAM2-3
1500
1500
6
3
1500
6.5-12
LAM3-1
6000
5000
12
6
5000
4-5.5
LAM3-2
4000
4000
10
5
4000
5.5-7.5
LAM3-4
2000
2000
8
4
1500
11.5-14.5
LAS1-1
1200
1200
6
2.5
800
8-12
LAS1-2
600
600
6
3
300
16-25
LAS2-1
1800
1200
6
3
1800
4.5-7
LAS3-1
1200
1200
6
2.5
800
8-12
LAS3-2
600
600
6
3
300
16-25
LAS4-1
800
800
5
2.3
600
10-15
LAS4-2
300
300
6
3.6
200
30-46
LAN1-1
5000 5000
11 5000 3-6
LAN1-2
4000
4000
11
4000 4-8
LAN1-3
3000
3000
10
3000
5-10
LAN3A-1
12000
6000
8.3
6000
24VDC 24VDC(24Q)
3-5
4.5-7
LAN3A-2
10000
6000
8.3 6000
4.5-8
7-11
LAN3A-3
7000
6000
8 6000
7-9
9-13
LAN3A-4
5000
5000
7 5000
9.5-12.5
13-18
LAN4-1
3500
3500
12
6
3500
3.5-7
LAN4-2
3000
3000
12
6
3000
4.2-9
LAN4-3
2000
2000
12
5
2000
6-13
LAN4-4
1500
1500
12
5
1500
8.5-20

MA99UE17-1804
7
TYPE
Max.
Push Force
(N)
Max.
Pull Force
(N)
Max. Cyrrent(A)
Max Holing Force (N)
Speed
(mm/s)
LAN5-1
8000
4000
24VDC
24VDC
(24Q)
24VDC
24VDC(24Q)
24VDC
24VDC(24Q)
7000(24Q)
5
5
8
6000
6000
2-3.5
5-7
LAN5-2
6000
4000
4.5
8
5000
5000
3-4.5
7-9
LAN5-3
4000
3000
4
6
4000
4000
4-5.5
9-11
LAN5-4
3000
2000
4
6
1500
1500
6-9
14-19
LAC1
2000
500
5
8
2000
8-12
13-16
NOTE:The test results are obtained by using the 12VDC or 24VDC power supply.
1.2 Input Voltage: 24VDC or 12 VDC; tolerance ±10%. The rated voltage of actuator is indicated in the label
or enclosed document.
1.3 Rated Duty Cycle: 10%
Definition: 2mis work and 18min pause.
1.4 Protection Class: IP54 (if not specially indicated)
1.5 Operating Temperature: +5℃ ~ +40℃ (+41°F ~ 104°F)
1.6 Atmospheric Pressure 860~1060hpa(12.5~15.4psi).
1.7 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen
or nitrous oxide.

MA99UE17-1804
8
2. Installation Guide
2.1 Please ensure that the extension tube is in the "lowest position" before installing actuators.
2.1.1 The term "lowest position" in this user's guide refers to the position such that there is no further
movement towards the DC motor while the actuator is powered on. (Please refer to the figure
below.)
2.1.2 External limit switch: For installing an external limit switch, please ensure the extension tube
is in the lowest position before installing an actuator (Please refer to the figure below.).
※If an actuator doesn't have an external limit switch installed, you must install the stroke limiter on an actuator yourself.
The distance between two actuator limit switches can't be longer than the stroke of the actuator. And then rotate the
extension tube to adjust the length of an actuator, which can meet the minimum requirements to install actuators.
※To avoid any wrong movements of actuators, there shouldn't have any magnetic materials close to external limit
switches within 30mm.

MA99UE17-1804
9
2.1.3 LAC1 Installation
2.2 The front and end joints of the linear actuator should be mounted onto two fixed positions on the main
chassis. Locations of these fixed positions should be chosen according to the stroke length of the linear
actuator (Users must be cautious that the two-way movement of linear actuator must be smooth and within
the stroke length after installed onto the fixed positions). Please ensure that no obstacle exists along the
travel path of the actuator.
2.3 After the fixed positions have been selected, install the fixtures onto these selected positions of the main
chassis. These fixtures are used to fix the front and end joints of linear actuator to the chassis.
2.4 Assemble the front and end joints of the linear actuator onto the two fixtures using fixture bolts. Please
ensure that the fixture bolts are able to rotate freely after this step is completed. On the other hand, users
should also make sure that the fixture bolts would not drop off either during operating or resting period.
2.5 The chassis of linear actuator should be fixed in the horizontal direction if it is going to be operated in this
direction and likewise for vertical operation.
2.6 The operation of the linear actuator should be tested manually after the installation is completed. Users
should make sure that:
The travel distance of the actuator is matching the requirement of the structural design.
The upper and lower limit switches are operated normally.
The motor stops when the extension tube reaches upper and lower limit switch positions.
If the linear actuator fails to meet any of these conditions, please repeat steps 2.2 to 2.4 until the above
mentioned clauses are met

MA99UE17-1804
10
2.7 The entire installation is finished only if steps 2.1 to 2.6 are executed successfully.
2.8 HIWIN Mikrosystem Corp. cannot take any responsibility for any injuries and/or damages caused as a
result of not complying with the clauses of this section.
3. Note:
3.1 Don't use this product to make current transient inversion. If you try to backwardly move the present
extension tube that forwardly moves, you must stop the motor and apply the reverse current to make
backward movement. On the contrary, if you want the extension tube backward moved to forward, the
way to supply current will be the same as mentioned above.
3.2 Don't use this product with a radial load (Please refer to figures and tables below.) because an actuator
more appropriately applies to take the axial load. If there is product damage, accident or personal injury
caused by improper load, we will not take any legal responsibility.
3.2.1 LA Series
3.2.2 LAC1 Series
3.3 For fixing the extension tube in this actuator on one guding mechanism, please refer to the installation guide.
If it is not fixed on any mechanism, it could idle.

MA99UE17-1804
11
4. Linear Actuator with Quick-Release User’s Guide
4.1 LAN3A Series:
4.1.1 To avoid mistake touching, please put up warning notice on the mechanisms or lifters.
4.1.2 The way to active quick-release is pulling the handle as the following drawing.
4.1.3 When the speed of quick-release is too fast, please adjust the handle extending length immediately;
The screw beside the handle can adjust and limit the max. extending length of the handle.
4.1.4 The quick-release function for LAN3A series can only be used in vertical pushing force condition, it
may inactive in pulling force or slopping force.
4.2 LAN5 Series:
4.2.1 Be sure the release cable is normal extended without any crooked when assembling, and the
end of wire is certainty fixed on the mechanisms or hospital beds.
4.2.2 To avoid mistake touching, please put up warning notice on the mechanism or facilities.
4.2.3 The way to active quick-release is pulling the handle and let the wire extend as the following
drawing.
4.2.4 Please lift the load temporary before active quick-release function, thus can pull the wire out
and separate the clutch mechanism.
4.2.5 Be sure to keep the clutch separated and restore the load on actuator, and the load can extend
and retract along axis direction.

MA99UE17-1804
12
4.2.6 The load on actuator cannot be the operating staff himself.
4.2.7 Be sure the release handle and clutch mechanism are restored by extending or retracting
the actuator after quick-release function is actived.

MA99UE17-1804
13
Chapter 2 LAK Series Controller User's Guide
1. Product Specification and Operation Environment
1. LAK2LR Series:
1.1 LAK2LR can combine uniaxial linear actuator with external limit switch.
1.2 The output power of a controller is 108VA (The output voltage is 24VDC.).
1.3 Fuse specification:2A/20mm(220/230VAC),
3A/20mm(100/110VAC).
2. LAK2 Series:
2.1 LAK2 can combine uniaxial or bi-axial linear actuators. For the sake of safety, two actuators can't be
operated simultaneously. Don't press the “△” key a nd “▽” key at the sa m e tim e.
2.2 The output power of a controller is 108VA (The output voltage is 24VDC.).
2.3 LAK2 can be driven by DC (12VDC / 24VDC), which the output power depends on the maximum power
of power supply.
2.4 Fuse specification:2A/20mm(220/230VAC),
3A/20mm(100/110VAC),
15A/20mm(12VAC).
3. LAK2 Series(UL):
3.1 LAK2 can combine uniaxial or bi-axial linear actuators. For the sake of safety, two actuators can't be
operated simultaneously. Don't press the “△” key and “▽” key a t the sam e tim e.
3.2 The output power of a controller is Max.144VA.
3.3 The input power is 100~240VAC.
3.4 Over currentA:2.5A, B:3A, C:4A, D:5A, E:6A
3.5 Recommended installation method:
4. LAK2BN Series:
4.1 LAK2B can combine uniaxial or bi-axial linear actuators, and provide an intelligent controller as well as
application software according to customer requirements.
4.2 The output power of a LAK2B controller is 144VA (The output voltage is 24VDC.).
4.3 1.3Ah or 2.9Ah lead acid batteries can be selected, built-in auto charge circuit without an external charger.
4.4 Fuse specification:2A/20mm(220/230VAC),
3A/20mm(100/110VAC),
10A/20mm(Battery).
4.5 Note: Please charge battery for at least 8 hours before initial use.

MA99UE17-1804
14
5. LAK2D Series:
5.1 LAK2D can combine uniaxial or bi-axial linear actuators. For the sake of safety, two actuators can’t be
operated simultaneously. Don’t press the “△” key and “▽” key a t the sam e tim e.
5.2 The output power of a controller is 108VA (The output voltage is 24VDC.).
5.3 LAK2D is equipped with auto protector to avoid over current caused by overload or other abnormal
situations; two 9V alkaline batteries can be added during temporary interruption to reduce the load.
5.4 LAK2D has no charge function, the battery can only afford the load to be declined urgently under a
powerless state.
5.5 LAK2D can combine LAM3 to save the space and be easily installed (Please refer to the figure below.).
5.6 Fuse specification:2A/20mm(220/230VAC),
3A/20mm(100/110VAC).
6. LAK2J Series(UL approved only DC IN versions):
6.1 LAK2J can combine uniaxial or bi-axial linear actuators.
6.2 A portable controller is designed in this product driven by two 12VDC lead acid batteries with 4.5Ah
without built-in transformer.
6.3 The EMERGENCY button on a panel can disconnect the function of a controller to protect customers
users.
6.4 Users can directly press the UP on DOWN key on a panel without a key box (The button can only be use
to do the up and down control for the first axis).
6.5 Over current protection and slow start are provided to avoid misuse.
6.6 A LAKCH-A charger is required for charging, (For the sake of safety, a controller can’t be used in charging.).
6.7 In 30 seconds after stopping operation, it will automatically become energy-saving mode to increase the
use time. The low-level buzz and LED power indication are provided as well.
6.8 When the controller is idle, please still keep the controller supplied with power (power cable connected),
when the controller is not in use, please press down the emergency button to save battery power.
6.9 Fuse specification:15A/20mm.
6.10Note: Please charge battery for at least 12 hours before initial use.
6.11Do not disconnect the cable connector when actuator is running.

MA99UE17-1804
15
7. LAK4D Series (UL):
7.1 LAK4D can combine uniaxial to 4-axial linear actuator.
7.2 The output power of a controller is 72.5VA (The output voltage is 24VDC).
7.3 A bolt is provided to avoid actuators cord and pluggable AC power cord from accidentally being removed
as well as reduce the danger when using.
7.4 LAK4D can combine with HIWIN linear actuator LAN5, and has an anti-loose function to prevent an actuator
from being removed; it is saving space and easy to install. (Please refer to the figure below)
7.5 LED power display.
7.6 Fuse specification:2A/20mm(220/230VAC),
3A/20mm(100/110VAC).
7.7 The protective rank of anti-shock of this product is BF.
7.8 The sign on the case of this product indicates that here is a function for“Functional Ground”.(For the
moment,we don’t provide the function).
8. LAK6B Series:
8.1 Combine uniaxial to 6-axial actuators, and provide an intelligent controller as well as application software
according to customer requirements.
8.2 The output power of a controller is 216VA (The output voltage is 24VDC.).
8.3 3Ah lead acid batteries can be selected, built-in auto charge circuit without an external charger.
8.4 Over current protection and slow start.
8.5 Energy-saving device and replaceable fuse with spare one on a socket.
8.6 External grounding and LED power indication.
8.7 Fuse specification:4A/20mm(100/110/220/230VAC).

MA99UE17-1804
16
2. System Overview
1. LAK2LR Series:
Taking LAM1 for example
2. LAK2 Series:
Taking LAN5 for example

MA99UE17-1804
17
3. LAK2BN Series:
Taking LAN5/LAC1 for example
4. LAK2D Series:
Taking LAM3 and LAN1 for example

MA99UE17-1804
18
5. LAK2J (DC-IN)Series:
Taking LAN3A for example
6. LAK4D Series:
Taking LAN5 for example

MA99UE17-1804
19
7. LAK6B Series:
Taking LAN3A and LAN5 for example
Other manuals for LA Series
1
This manual suits for next models
32
Table of contents
Other Hiwin Controllers manuals
Popular Controllers manuals by other brands

Sensus
Sensus 441-57S Installation and maintenance instructions

Advanced Control Technologies
Advanced Control Technologies th104 installation instructions

YOKOGAWA
YOKOGAWA UT35A/RSP Operation guide

Samson
Samson TROVIS 5433 quick guide

DAB
DAB SMART PRESS WG 1,5HP User manual instructions for installation and maintenance

Cutler-Hammer
Cutler-Hammer EATON PanelMate ControlNet manual