INBACSAM***O000
Samsung NASA to BACnet Server gateway
Order Code: INBACSAM***O000
*** stands for the Intesis gateway capacity and varies depending on the specific gateway acquired
Installation Sheet rev.1.1
HMS Industrial Networks S.L.U ©
SAFETY INSTRUCTIONS
!WARNING
Follow carefully this safety and installation instructions.
Improper work may lead to serious harmful for your health
and also may damage seriously the Intesis gateway and/or
any other equipment connected to it.
The Intesis device must be installed by accredited electrician or similar
technical personnel, following all the safety instructions given here and
in accordance always with the country legislation for installation of
electric equipment.
The Intesis device cannot be installed outdoors or exposed to direct
solar radiation, water, high relative humidity or dust.
The Intesis gateway must only be installed in a restricted access
location.
In case of wall mount, fix firmly the Intesis gateway on a not vibrating
surface following the instructions next.
In case of DIN rail mount fix the Intesis device properly to the DIN rail
following the instructions below.
Mounting on DIN rail inside a metallic cabinet properly connected to
earth is recommended.
Disconnect always power of any wires before manipulating and
connecting them to the Intesis gateway.
A power supply with an NEC Class 2 or Limited Power Source (LPS)
and SELV rated is to be used.
Respect always the expected polarity of power and communication
cables when connecting them to the Intesis gateway.
Supply always a correct voltage to power the Intesis gateway, see
details of voltage range admitted by the device in the technical
characteristics below.
CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type.
Dispose of Used Batteries according to the instructions. Battery
replacement shall be done by an authorized installer.
CAUTION: The device is to be connected only to networks without
routing to the outside plant, all communication ports are considered for
indoor only and can be connected SELV circuits only.
This device was designed for installation in an enclosure. To avoid
electrostatic discharge to the unit in environments with static levels
above 4 kV, precautions should be taken when the device is mounted
outside an enclosure. When working in an enclosure (ex. making
adjustments, setting switches etc.) typical anti-static precautions
should be observed before touching the unit.
Safety instructions in other languages can be found at:
https://intesis.com/docs/manuals/v6-safety
INSTALLATION
Follow instructions next to properly install the gateway.
Disconnect from mains the power supply before connecting it to the
Intesis device.
Disconnect power of any bus or communication cable before
connecting it to the Intesis gateway.
Mount the Intesis gateway on the wall or DIN rail following the
instruction given below, respecting the safety instructions given above.
Connect a NEC Class 2 or Limited Power Source (LPS) and SELV
rated power supply to the Intesis device, respect the polarity if DC
power or Line and Neutral if AC power. Apply always a voltage within
the range admitted by the Intesis device and of enough power (see
technical characteristics).
Circuit-breaker must be used before the power supply. Rating 250V-
6A.
Connect the communication cables to the Intesis gateway, see details
on the user's manual.
Power the Intesis gateway and the rest of devices connected to it.
NOTE: The device cannot be installed in air-handling space.
Wall Mount
1. Separate the fixing clips in the bottom of the box, pushing
them to the outside until hear the "click" which indicates that
now the clips are in position for wall mount, see in the figure
below.
2. Use the holes of the to fix the box in the wall using screws.
Use the template below for the wall wholes.
Clips in their original position Clips in position for wall mount
(for DIN rail mount)
DIN Rail Mount
With the clips of the box in their original position, insert first the box
in the upper edge of the DIN rail and later insert the box in the down
part of the rail, using a small screwdriver and following the steps in
the figure below.
Press
Press
Press
CONFIGURATION
Use the Configuration Tool to configure the gateway.
See instructions to download and install the latest version at:
https://intesis.com/docs/software/intesis-maps-installer
Use the Ethernet connection or the Console Port (mini USB type B
connector included) to get communication between the gateway and
the configuration tool.
Follow instructions of the user's manual for more details.
Owner’s Record
The serial number is located at the rear of the gateway.
Record this information in the space provided below.
Refer to it whenever you contact upon your gateway
dealer or support team regarding this product.
Serial No.
© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
URL https://www.intesis.com
Rev.1.1
2 / 2
Enclosure
Plastic, type PC (UL 94 V-0)
Net dimensions (dxwxh): 90x88x56 mm
Recommended space for installation (dxwxh): 130x100x100mm
Color: Light Grey. RAL 7035
Battery
Size: Coin 20mm x 3.2mm
Capacity: 3V / 225mAh
Type: Manganese Dioxide Lithium
Mounting
Wall.
DIN rail EN60715 TH35.
Console Port
Mini Type-B USB 2.0 compliant
1500VDC isolation
Terminal Wiring
(for power supply and
low-voltage signals)
Per terminal: solid wires or stranded wires (twisted or with
ferrule)
1 core: 0.5mm2… 2.5mm2
2 cores: 0.5mm2… 1.5mm2
3 cores: not permitted
If cables are more than 3.05 meters long, Class 2 cable is required.
USB port
Type-A USB 2.0 compliant
Only for USB flash storage device
(USB pen drive)
Power consumption limited to 150mA
(HDD connection not allowed)
Power
1 x Plug-in screw terminal block (3 poles)
9 to 36VDC +/-10%, Max.: 140mA.
24VAC +/-10% 50-60Hz, Max.: 127mA
Recommended: 24VDC
Push Button
Button A: Not used
Button B: Broadcast I-Am message in the
BACnet network
Operation
Temperature
0°C to +60°C
Ethernet
1 x Ethernet 10/100 Mbps RJ45
2 x Ethernet LED: port link and activity
Operational
Humidity
5 to 95%, no condensation
Port A
1 x Samsung Nasa port Plug-in screw terminal block orange (2
poles)
R1 R2 (Samsung Nasa)
1500VDC isolation from other ports
1 x Plug-in screw terminal block green (2 poles)
Reserved for future use
Protection
IP20 (IEC60529)
LED
Indicators
10 x Onboard LED indicators
2 x Run (Power)/Error
2 x Ethernet Link/Speed
2 x Port A TX/RX
2 x Port B TX/RX
1 x Button A indicator
1 x Button B indicator
Switch A
(SWA)
1 x DIP-Switch for serial EIA485 configuration:
Reserved for future use, leave defaults (all OFF)
PORT B
1 x Serial EIA232 (SUB-D9 male connector)
Reserved for future use
1 x Serial EIA485 Plug-in screw terminal block (3 poles)
A, B, SGND (Reference ground or shield)
1500VDC isolation from other ports
(except PORT B: EIA232)
Switch B
(SWB)
1 x DIP-Switch for serial EIA485 configuration:
Position 1:
ON: 120 Ω termination active
Off: 120 Ω termination inactive (default)
Position 2-3:
ON: Polarization active
Off: Polarization inactive (default)
CONNECTIONS
ELECTRICAL & MECHANICAL FEATURES
Power Supply
Must use NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply.
If using DC power supply:
Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within the range admitted
(check table below). The power supply can be connected to earth but only through the negative terminal,
never through the positive terminal.
If using AC power supply:
Make sure the voltage applied is of the value admitted (24 Vac). Do not connect any of the terminals of the
AC power supply to earth, and make sure the same power supply is not supplying any other device.
Ethernet / BACnet IP (UDP) / Console (UDP & TCP)
Connect the cable coming from the IP network to the connector ETH of the gateway. Use an Ethernet CAT5
cable. If communicating through the LAN of the building, contact the network administrator and make sure traffic
on the port used is allowed through all the LAN path (check the gateway user manual for more information).
Default IP is 192.168.100.246.
PortA / R1/R2 Samsung NASA
Connect the R1/R2 bus of Samsung NASA Outdoor Units to the connectors A3 (R1) A4 (R2) of gateway’s PortA.
Respect the polarity.
PortB / BACnet MSTP
Connect the EIA485 bus toconnectors B1 (B+), B2 (A-) and B3 (SNGD) of gateway’s PortB. Respect the polarity.
Remember the characteristics of the standard EIA485 bus: maximum distance of 1200 meters, maximum 32
devices connected to the bus, and in each end of the bus it must be a termination resistor of 120 Ω. Bus biasing
and termination resistor for EIA485 can be enabled for PortB by means of a dedicated DIP switch –see table
below.
Console Port
Connect a mini-type B USB cable from your computer to the gateway to allow communication between the
Configuration Software and the gateway. Remember that Ethernet connection is also allowed. Check the user
manual for more information.
USB
Connect a USB storage device (not a HDD) if required. Check the user manual for more information.
Power Supply
Ethernet
BACnet IP
USB
storage
BACnet MSTP
Console
Port
100 mm (h)
100 mm (w)
130 mm (d)
Samsung
NASA
R1/R2
This marking on the product, accessories, packaging or literature (manual) indicates that the product contains electronic
parts and they must be properly disposed of by following the instructions at https://intesis.com/weee-regulation

This manual suits for next models

4

Other HMS Gateway manuals

HMS ABC-LON-RTU SLAVE User manual

HMS

HMS ABC-LON-RTU SLAVE User manual

HMS Anybus Communicator CAN PROFINET IRT 2.32 User manual

HMS

HMS Anybus Communicator CAN PROFINET IRT 2.32 User manual

HMS Intesis INBACHIT O000 Series Assembly instructions

HMS

HMS Intesis INBACHIT O000 Series Assembly instructions

HMS Ixxat SG-gateway User guide

HMS

HMS Ixxat SG-gateway User guide

HMS Intesis INMBSOCP 0100 Series Assembly instructions

HMS

HMS Intesis INMBSOCP 0100 Series Assembly instructions

HMS Intesis WMP User manual

HMS

HMS Intesis WMP User manual

HMS Anybus 024380-C User manual

HMS

HMS Anybus 024380-C User manual

HMS Anybus-X User manual

HMS

HMS Anybus-X User manual

HMS HGP 115 Installation and operating manual

HMS

HMS HGP 115 Installation and operating manual

HMS Intesis KNX User manual

HMS

HMS Intesis KNX User manual

HMS Intesis IN776MHI00 O000 Series Assembly instructions

HMS

HMS Intesis IN776MHI00 O000 Series Assembly instructions

HMS AB7307 User manual

HMS

HMS AB7307 User manual

HMS Intesis KNX Series User manual

HMS

HMS Intesis KNX Series User manual

HMS IXXAT CANbridge User manual

HMS

HMS IXXAT CANbridge User manual

HMS HMS-EN2MB-R User manual

HMS

HMS HMS-EN2MB-R User manual

HMS Anybus Communicator PROFINET-USS User manual

HMS

HMS Anybus Communicator PROFINET-USS User manual

HMS Anybus-X AB7609 User manual

HMS

HMS Anybus-X AB7609 User manual

HMS Anybus-X AB7609 User manual

HMS

HMS Anybus-X AB7609 User manual

HMS Anybus Modbus to KNX Gateway User manual

HMS

HMS Anybus Modbus to KNX Gateway User manual

HMS Netbiter EasyConnect EC150 User manual

HMS

HMS Netbiter EasyConnect EC150 User manual

HMS Anybus X-gateway User manual

HMS

HMS Anybus X-gateway User manual

HMS Intesis IN485MHI001R000 User manual

HMS

HMS Intesis IN485MHI001R000 User manual

HMS Intesis INKNXMBM1000100 Assembly instructions

HMS

HMS Intesis INKNXMBM1000100 Assembly instructions

HMS Ewon Cosy+ User manual

HMS

HMS Ewon Cosy+ User manual

Popular Gateway manuals by other brands

RTA 460PSBC-NNA1 Product user guide

RTA

RTA 460PSBC-NNA1 Product user guide

Linksys WAG300N (EU/LA) user guide

Linksys

Linksys WAG300N (EU/LA) user guide

DASAN KYS DKC1001 user manual

DASAN KYS

DASAN KYS DKC1001 user manual

SkyLine SK GoIP user manual

SkyLine

SkyLine SK GoIP user manual

RTA 460ECDFM-NNA1 Product user guide

RTA

RTA 460ECDFM-NNA1 Product user guide

Philips Dynalite PDZG-E installation instructions

Philips

Philips Dynalite PDZG-E installation instructions

Speedtouch 580 user guide

Speedtouch

Speedtouch 580 user guide

Multitech MULTIVOIP MVP-210 user guide

Multitech

Multitech MULTIVOIP MVP-210 user guide

Digium G100 SERIES Administrator's manual

Digium

Digium G100 SERIES Administrator's manual

Sole Digital STL100 Installation and user manual

Sole Digital

Sole Digital STL100 Installation and user manual

RTA 460ESMS-NNA1 Product user guide

RTA

RTA 460ESMS-NNA1 Product user guide

ZyXEL Communications UAG50 user guide

ZyXEL Communications

ZyXEL Communications UAG50 user guide

Laars ProtoNode FPC-N34 Startup guide

Laars

Laars ProtoNode FPC-N34 Startup guide

ABB AWIN GW120 user manual

ABB

ABB AWIN GW120 user manual

ActionTec GT701-WG user manual

ActionTec

ActionTec GT701-WG user manual

WELLTECH FXS H.323 Gateway user manual

WELLTECH

WELLTECH FXS H.323 Gateway user manual

Crestron CENI-GWEXER Installation instructions manual

Crestron

Crestron CENI-GWEXER Installation instructions manual

Tainet Venus Series user manual

Tainet

Tainet Venus Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.