manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HMS
  6. •
  7. Gateway
  8. •
  9. HMS Intesis INMBSOCP 0100 Series Assembly instructions

HMS Intesis INMBSOCP 0100 Series Assembly instructions

This manual suits for next models

1

Other HMS Gateway manuals

HMS Anybus X-Gateway Series User manual

HMS

HMS Anybus X-Gateway Series User manual

HMS Intesis INMBSHIS016O000 User manual

HMS

HMS Intesis INMBSHIS016O000 User manual

HMS Netbiter EasyConnect EC220 Specification sheet

HMS

HMS Netbiter EasyConnect EC220 Specification sheet

HMS Intesis WMP User manual

HMS

HMS Intesis WMP User manual

HMS AB9008 User manual

HMS

HMS AB9008 User manual

HMS Intesis INMBSPAN016O000 User manual

HMS

HMS Intesis INMBSPAN016O000 User manual

HMS Ewon Cosy+ User manual

HMS

HMS Ewon Cosy+ User manual

HMS Anybus X-gateway CANopen Series User manual

HMS

HMS Anybus X-gateway CANopen Series User manual

HMS Anybus Modbus-TCP/RTU Gateway User manual

HMS

HMS Anybus Modbus-TCP/RTU Gateway User manual

HMS Intesis INBACDAL1280200 Assembly instructions

HMS

HMS Intesis INBACDAL1280200 Assembly instructions

HMS Netbiter EasyConnect Series User manual

HMS

HMS Netbiter EasyConnect Series User manual

HMS Intesis INKNXMBM1000100 Assembly instructions

HMS

HMS Intesis INKNXMBM1000100 Assembly instructions

HMS AnyBus-X J1939 User manual

HMS

HMS AnyBus-X J1939 User manual

HMS Intesis KNX - Hisense VRF User manual

HMS

HMS Intesis KNX - Hisense VRF User manual

HMS Anybus X-gateway User manual

HMS

HMS Anybus X-gateway User manual

HMS Intesis WMP User manual

HMS

HMS Intesis WMP User manual

HMS Anybus Communicator PROFINET-USS User manual

HMS

HMS Anybus Communicator PROFINET-USS User manual

HMS Anybus Edge User manual

HMS

HMS Anybus Edge User manual

HMS Intesis IN485MHI001R000 User manual

HMS

HMS Intesis IN485MHI001R000 User manual

HMS AnyBus-X J1939 User manual

HMS

HMS AnyBus-X J1939 User manual

HMS AB7307 User manual

HMS

HMS AB7307 User manual

HMS Anybus  X-gateway CANopen User manual

HMS

HMS Anybus X-gateway CANopen User manual

HMS AnyBus-X AB7607 User manual

HMS

HMS AnyBus-X AB7607 User manual

HMS HMS-EN2MB-R User manual

HMS

HMS HMS-EN2MB-R User manual

Popular Gateway manuals by other brands

Telecom FM onestream gfx Programming guide

Telecom FM

Telecom FM onestream gfx Programming guide

UfiSpace LoRa GPE810U Quick setup guide

UfiSpace

UfiSpace LoRa GPE810U Quick setup guide

Merak MMk-736F Quick setup guide

Merak

Merak MMk-736F Quick setup guide

Robustel R3010 user guide

Robustel

Robustel R3010 user guide

turck BL20-PG-EN-V3 user manual

turck

turck BL20-PG-EN-V3 user manual

IBM Security Web Gateway Appliance quick start guide

IBM

IBM Security Web Gateway Appliance quick start guide

SSS Siedle Smart Gateway Commissioning instructions

SSS Siedle

SSS Siedle Smart Gateway Commissioning instructions

ADTRAN 424RG Installation

ADTRAN

ADTRAN 424RG Installation

Chorus Hyperfibre XGS-250WX-A user guide

Chorus

Chorus Hyperfibre XGS-250WX-A user guide

Dragino G308 user manual

Dragino

Dragino G308 user manual

Data Domain DD690g Installation and setup guide

Data Domain

Data Domain DD690g Installation and setup guide

Raritan Laptop Release notes

Raritan

Raritan Laptop Release notes

Haivision Torpedo quick start guide

Haivision

Haivision Torpedo quick start guide

ATCOM AG-268 user manual

ATCOM

ATCOM AG-268 user manual

LST M500RFE-AS Specification sheet

LST

LST M500RFE-AS Specification sheet

Vega VEGA BS-3 user manual

Vega

Vega VEGA BS-3 user manual

Kinnex Media Gateway quick start guide

Kinnex

Kinnex Media Gateway quick start guide

2N Telekomunikace 2N StarGate user manual

2N Telekomunikace

2N Telekomunikace 2N StarGate user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
URL https://www.intesis.com
Rev.1.3
1 / 2
INMBSOCP***0100
Order Code: INMBSOCP***0100
** stands for the Intesis gateway capacity and varies depending on the specific gateway acquired
Installation Sheet rev.1.3
HMS Industrial Networks S.L.U ©
SAFETY INSTRUCTIONS
!WARNING
Follow carefully this safety and installation instructions.
Improper work may lead to serious harmful for your health
and may also damage seriously the Intesis gateway and/or
any other equipment connected to it.
The Intesis gateway must be installed by accredited electrician or
similar technical personnel, following all the safety instructions given
here and in accordance always with the country legislation for
installation of electric equipment.
The Intesis gateway cannot be installed outdoors or exposed to direct
solar radiation, water, high relative humidity or dust.
The Intesis gateway must only be installed in a restricted access
location.
In case of wall mount, fix firmly the Intesis gateway on a not vibrating
surface following the instructions next.
In case of DIN rail mount fix the Intesis gateway properly to the DIN rail
following the instructions below.
Mounting on DIN rail inside a metallic cabinet properly connected to
earth is recommended.
Disconnect always power of any wires before manipulating and
connecting them to the Intesis gateway.
A power supply with an NEC Class 2 or Limited Power Source (LPS)
and SELV rated is to be used.
Respect always the expected polarity of power and communication
cables when connecting them to the Intesis gateway.
Supply always a correct voltage to power Intesis gateway, see details
of voltage range admitted by the device in the technical characteristics
below.
CAUTION: The device is to be connected only to networks without
routing to the outside plant, all communication ports are considered for
indoor only.
This device was designed for installation in an enclosure. To avoid
electrostatic discharge to the unit in environments with static levels
above 4 kV, precautions should be taken when the device is mounted
outside an enclosure. When working in an enclosure (ex. making
adjustments, setting switches etc.) typical anti-static precautions
should be observed before touching the unit.
Safety instructions in other languages can be found at:
https://intesis.com/docs/manuals/v6-safety
INSTALLATION
Follow instructions next to properly install the Intesis gateway.
Disconnect from mains the power supply before connecting it to the
Intesis gateway.
Disconnect power of any bus or communication cable before
connecting it to the Intesis gateway.
Mount the Intesis gateway in a vertical position on the wall or DIN rail
following the instruction given below, respecting the safety instructions
given above.
IMPORTANT: Connect a NEC Class 2 or Limited Power Source (LPS)
and SELV rated power supply to the Intesis gateway, respect the
polarity if DC power or Line and Neutral if AC power. This power
supply must not be shared with other devices. Apply always a
voltage within the range admitted by the Intesis gateway and of enough
power (see technical characteristics).
Circuit-breaker must be used before the power supply. Rating 250V-
6A.
Connect the communication cables to the Intesis gateway, see details
on the user's manual.
Power the Intesis gateway and the rest of devices connected to it.
Wall Mount
1. Separate the fixing clips in the bottom of the box, pushing
them to the outside until hear the "click" which indicates that
now the clips are in position for wall mount, see in the figure
below.
2. Use the holes of the clips to fix the box in the wall using
screws. Use the template below for the wall wholes.
Clips in their original position Clips in position for wall mount
(for DIN rail mount)
DIN Rail Mount
With the clips of the box in their original position, insert first the box
in the upper edge of the DIN rail and later insert the box in the down
part of the rail, using a small screwdriver and following the steps in
the figure below.
DIN Rail
1
2
3
CONFIGURATION
Use the Configuration Tool to configure the Intesis gateway.
See instructions to download and install the latest version at:
https://intesis.com/docs/software/intesis-maps-installer
Use the Ethernet connection for communication between the gateway
and the configuration tool. See CONNECTIONS below and follow
instructions of user’s manual for more details.
Press
Owner’s Record
The serial number is located at the rear of the gateway.
Record this information in the space provided below.
Refer to it whenever you contact upon your gateway
dealer or support team regarding this product.
Serial No.
© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
URL https://www.intesis.com
Rev.1.3
2 / 2
Enclosure
Plastic, type PC (UL 94 V-0)
Net dimensions (dxwxh): 93x53x58 mm
Recommended space for installation (dxwxh): 100x60x70mm
Color: Light Grey. RAL 7035
Mounting
Wall.
DIN rail EN60715 TH35.
Terminal Wiring
(for power supply and
low-voltage signals)
Per terminal: solid wires or stranded wires (twisted or with
ferrule)
1 core: 0.5mm2… 2.5mm2
2 cores: 0.5mm2… 1.5mm2
3 cores: not permitted
Power
1 x Plug-in screw terminal block (3 poles)
Positive, Negative, Earth
9-36 VDC / 24 VAC / 50-60 Hz / 0.140 A / 1.7 W
Ethernet
1 x Ethernet 10/100 Mbps RJ45
2 x Ethernet LED: port link and activity
Port
1 x Serial EIA485 (Plug-in screw terminal block 3 poles)
A, B, SGND (Reference ground or shield)
1500VDC isolation from other ports
Operation
Temperature
0°C to +60°C
Operational
Humidity
5 to 95%, no condensation
Protection
IP20 (IEC60529)
CONNECTIONS
ELECTRICAL & MECHANICAL FEATURES
Power Supply
Must use NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply.
Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within
the range admitted (check table below). The power supply can beconnected to earth
but only through the negative terminal, never through the positive terminal.
Ethernet / Modbus TCP / OCPP
Connect the cable coming from the IP network to the connector ETH of the Intesis
gateway. Use an Ethernet CAT5 cable. If communicating through the LAN of the
building, contact the network administrator and make sure traffic on the port used is
allowed through all the LAN path (check the Intesis gateway user manual for more
information). With factory settings, after powering up the Intesis gateway, DHCP will
be enabled for 30 seconds. After that time, if no IP is provided by a DHCP server,
the default IP 192.168.100.246 will be set.
Port Modbus RTU
Connect the EIA485 bus to connectors A3 (B+), A2 (A-) and A1 (SNGD) of Intesis
gateway’s Port. Respect the polarity.
Note for EIA485 port; Remember the characteristics of the standard EIA485 bus:
maximum distance of 1200 meters, maximum 32 devices connected to the bus, and
in each end of the bus it must be a termination resistor of 120 Ω.
Power
Supply
Modbus
RTU
Ethernet
OCPP
Modbus TCP
70mm (h)
60 mm (w)
100 mm (d)
This marking on the product, accessories, packaging or literature (manual) indicates that the product contains electronic
parts and they must be properly disposed of by following the instructions at https://intesis.com/weee-regulation
ETH- Port A