1 / 2
INMBSOCP***0100
Order Code: INMBSOCP***0100
** stands for the Intesis gateway capacity and varies depending on the specific gateway acquired
Installation Sheet rev.1.3
HMS Industrial Networks S.L.U ©
SAFETY INSTRUCTIONS
!WARNING
Follow carefully this safety and installation instructions.
Improper work may lead to serious harmful for your health
and may also damage seriously the Intesis gateway and/or
any other equipment connected to it.
The Intesis gateway must be installed by accredited electrician or
similar technical personnel, following all the safety instructions given
here and in accordance always with the country legislation for
installation of electric equipment.
The Intesis gateway cannot be installed outdoors or exposed to direct
solar radiation, water, high relative humidity or dust.
The Intesis gateway must only be installed in a restricted access
location.
In case of wall mount, fix firmly the Intesis gateway on a not vibrating
surface following the instructions next.
In case of DIN rail mount fix the Intesis gateway properly to the DIN rail
following the instructions below.
Mounting on DIN rail inside a metallic cabinet properly connected to
earth is recommended.
Disconnect always power of any wires before manipulating and
connecting them to the Intesis gateway.
A power supply with an NEC Class 2 or Limited Power Source (LPS)
and SELV rated is to be used.
Respect always the expected polarity of power and communication
cables when connecting them to the Intesis gateway.
Supply always a correct voltage to power Intesis gateway, see details
of voltage range admitted by the device in the technical characteristics
below.
CAUTION: The device is to be connected only to networks without
routing to the outside plant, all communication ports are considered for
indoor only.
This device was designed for installation in an enclosure. To avoid
electrostatic discharge to the unit in environments with static levels
above 4 kV, precautions should be taken when the device is mounted
outside an enclosure. When working in an enclosure (ex. making
adjustments, setting switches etc.) typical anti-static precautions
should be observed before touching the unit.
Safety instructions in other languages can be found at:
https://intesis.com/docs/manuals/v6-safety
INSTALLATION
Follow instructions next to properly install the Intesis gateway.
Disconnect from mains the power supply before connecting it to the
Intesis gateway.
Disconnect power of any bus or communication cable before
connecting it to the Intesis gateway.
Mount the Intesis gateway in a vertical position on the wall or DIN rail
following the instruction given below, respecting the safety instructions
given above.
IMPORTANT: Connect a NEC Class 2 or Limited Power Source (LPS)
and SELV rated power supply to the Intesis gateway, respect the
polarity if DC power or Line and Neutral if AC power. This power
supply must not be shared with other devices. Apply always a
voltage within the range admitted by the Intesis gateway and of enough
power (see technical characteristics).
Circuit-breaker must be used before the power supply. Rating 250V-
6A.
Connect the communication cables to the Intesis gateway, see details
on the user's manual.
Power the Intesis gateway and the rest of devices connected to it.
Wall Mount
1. Separate the fixing clips in the bottom of the box, pushing
them to the outside until hear the "click" which indicates that
now the clips are in position for wall mount, see in the figure
below.
2. Use the holes of the clips to fix the box in the wall using
screws. Use the template below for the wall wholes.
Clips in their original position Clips in position for wall mount
(for DIN rail mount)
DIN Rail Mount
With the clips of the box in their original position, insert first the box
in the upper edge of the DIN rail and later insert the box in the down
part of the rail, using a small screwdriver and following the steps in
the figure below.
DIN Rail
1
2
3
CONFIGURATION
Use the Configuration Tool to configure the Intesis gateway.
See instructions to download and install the latest version at:
https://intesis.com/docs/software/intesis-maps-installer
Use the Ethernet connection for communication between the gateway
and the configuration tool. See CONNECTIONS below and follow
instructions of user’s manual for more details.
Press
Owner’s Record
The serial number is located at the rear of the gateway.
Record this information in the space provided below.
Refer to it whenever you contact upon your gateway
dealer or support team regarding this product.
Serial No.
© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
URL https://www.intesis.com
Rev.1.3
2 / 2
Enclosure
Plastic, type PC (UL 94 V-0)
Net dimensions (dxwxh): 93x53x58 mm
Recommended space for installation (dxwxh): 100x60x70mm
Color: Light Grey. RAL 7035
Mounting
Wall.
DIN rail EN60715 TH35.
Terminal Wiring
(for power supply and
low-voltage signals)
Per terminal: solid wires or stranded wires (twisted or with
ferrule)
1 core: 0.5mm2… 2.5mm2
2 cores: 0.5mm2… 1.5mm2
3 cores: not permitted
Power
1 x Plug-in screw terminal block (3 poles)
Positive, Negative, Earth
9-36 VDC / 24 VAC / 50-60 Hz / 0.140 A / 1.7 W
Ethernet
1 x Ethernet 10/100 Mbps RJ45
2 x Ethernet LED: port link and activity
Port
1 x Serial EIA485 (Plug-in screw terminal block 3 poles)
A, B, SGND (Reference ground or shield)
1500VDC isolation from other ports
Operation
Temperature
0°C to +60°C
Operational
Humidity
5 to 95%, no condensation
Protection
IP20 (IEC60529)
CONNECTIONS
ELECTRICAL & MECHANICAL FEATURES
Power Supply
Must use NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply.
Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within
the range admitted (check table below). The power supply can beconnected to earth
but only through the negative terminal, never through the positive terminal.
Ethernet / Modbus TCP / OCPP
Connect the cable coming from the IP network to the connector ETH of the Intesis
gateway. Use an Ethernet CAT5 cable. If communicating through the LAN of the
building, contact the network administrator and make sure traffic on the port used is
allowed through all the LAN path (check the Intesis gateway user manual for more
information). With factory settings, after powering up the Intesis gateway, DHCP will
be enabled for 30 seconds. After that time, if no IP is provided by a DHCP server,
the default IP 192.168.100.246 will be set.
Port Modbus RTU
Connect the EIA485 bus to connectors A3 (B+), A2 (A-) and A1 (SNGD) of Intesis
gateway’s Port. Respect the polarity.
Note for EIA485 port; Remember the characteristics of the standard EIA485 bus:
maximum distance of 1200 meters, maximum 32 devices connected to the bus, and
in each end of the bus it must be a termination resistor of 120 Ω.
Power
Supply
Modbus
RTU
Ethernet
OCPP
Modbus TCP
70mm (h)
60 mm (w)
100 mm (d)
This marking on the product, accessories, packaging or literature (manual) indicates that the product contains electronic
parts and they must be properly disposed of by following the instructions at https://intesis.com/weee-regulation
ETH- Port A

This manual suits for next models

1

Other HMS Gateway manuals

HMS Anybus X-Gateway Series User manual

HMS

HMS Anybus X-Gateway Series User manual

HMS Netbiter EasyConnect EC220 Specification sheet

HMS

HMS Netbiter EasyConnect EC220 Specification sheet

HMS Intesis INMBSHIS016O000 User manual

HMS

HMS Intesis INMBSHIS016O000 User manual

HMS Anybus Modbus to KNX Gateway User manual

HMS

HMS Anybus Modbus to KNX Gateway User manual

HMS ABC-LON-RTU SLAVE User manual

HMS

HMS ABC-LON-RTU SLAVE User manual

HMS Intesis WMP User manual

HMS

HMS Intesis WMP User manual

HMS AB7307 User manual

HMS

HMS AB7307 User manual

HMS Intesis INBACDAL1280200 Assembly instructions

HMS

HMS Intesis INBACDAL1280200 Assembly instructions

HMS Intesis INBACHIT O000 Series Assembly instructions

HMS

HMS Intesis INBACHIT O000 Series Assembly instructions

HMS Intesis KNX Series User manual

HMS

HMS Intesis KNX Series User manual

HMS Intesis KNX User manual

HMS

HMS Intesis KNX User manual

HMS Anybus Communicator PROFINET-USS User manual

HMS

HMS Anybus Communicator PROFINET-USS User manual

HMS Ixxat CAN@net NT 420 User manual

HMS

HMS Ixxat CAN@net NT 420 User manual

HMS Intesis WMP Series User manual

HMS

HMS Intesis WMP Series User manual

HMS Intesis INBACSAM004O000 User manual

HMS

HMS Intesis INBACSAM004O000 User manual

HMS Anybus X-gateway User manual

HMS

HMS Anybus X-gateway User manual

HMS AB9008 User manual

HMS

HMS AB9008 User manual

HMS Intesis INMBSPAN016O000 User manual

HMS

HMS Intesis INMBSPAN016O000 User manual

HMS AnyBus-X J1939 User manual

HMS

HMS AnyBus-X J1939 User manual

HMS Anybus HMS-EN2MB-R User manual

HMS

HMS Anybus HMS-EN2MB-R User manual

HMS Intesis KNX Mitsubishi Electric CC User manual

HMS

HMS Intesis KNX Mitsubishi Electric CC User manual

HMS Intesis INKNXFGL016O000 User manual

HMS

HMS Intesis INKNXFGL016O000 User manual

HMS Anybus-S Interbus User manual

HMS

HMS Anybus-S Interbus User manual

HMS Intesis KNX - Hisense VRF User manual

HMS

HMS Intesis KNX - Hisense VRF User manual

Popular Gateway manuals by other brands

Avaya Media Gateway G350 Quick start for hardware installation

Avaya

Avaya Media Gateway G350 Quick start for hardware installation

Juniper SRX5400 manual

Juniper

Juniper SRX5400 manual

Comcast HOME-5A58 user guide

Comcast

Comcast HOME-5A58 user guide

ADT Security Service iHub-3000B installation guide

ADT Security Service

ADT Security Service iHub-3000B installation guide

Baumer GK473 manual

Baumer

Baumer GK473 manual

Mellanox Technologies sRB-20210G user manual

Mellanox Technologies

Mellanox Technologies sRB-20210G user manual

Grundfos CIM 500 Functional profile and user manual

Grundfos

Grundfos CIM 500 Functional profile and user manual

SIOX SX:NETLINK ES3 manual

SIOX

SIOX SX:NETLINK ES3 manual

Samsung MIM-B18 user manual

Samsung

Samsung MIM-B18 user manual

Juniper SRX 210 Getting started guide

Juniper

Juniper SRX 210 Getting started guide

Thorsis Technologies isNet Series user manual

Thorsis Technologies

Thorsis Technologies isNet Series user manual

Matrix SETU VTEP quick start

Matrix

Matrix SETU VTEP quick start

Zoom IG-4160 user guide

Zoom

Zoom IG-4160 user guide

Kramer FC-28 quick start guide

Kramer

Kramer FC-28 quick start guide

AMX CSG-500 installation guide

AMX

AMX CSG-500 installation guide

OpenVox VS-EIU-100X Series user manual

OpenVox

OpenVox VS-EIU-100X Series user manual

SmartRG SR350n user manual

SmartRG

SmartRG SR350n user manual

Cisco EPC3925 datasheet

Cisco

Cisco EPC3925 datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.