Holtkamp Maxi 3300MC User manual

Operating instruction
Maxi 3300MC
Coin box

Important: For safe and proper use, read the instructions for use and further product-related documents carefully and keep
it for later use!
For errors, technical errors, printing errors and incompleteness, we assume no liability.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 3 -
Südstraße 40 / D-49084 Osnabrück
info@holtkamp.de /
www.holtkamp.de
Telefon: +49 541 97120-0, Fax: +49 541 97120-40
Geschäftsführung: Magnus Michael, Uwe Staudinger; Sitz der Gesellschaft: Osnabrück, AG Osnabrück HRB 213567
Banken: Deutsche Bank Osnabrück, IBAN: DE28 2657 0090 0039 5251 00; SW IFT/BIC: DEUTDE3B265
Die Lieferung erfolgt zu unseren Allgemeinen Geschäftsbedingungen mit Stand Juni 2011 nach ZVEI unter Einbeziehung der Softwareklausel
zur Überlassung von Standard-Software als Teil von Lieferungen mit Stand April 2012 nach ZVEI.
Zusätzlich gelten unsere Vertragsbedingungen „Hardware/Schaltplan/Layout“ und „Auftragsfertigung“.
Es gelten unsere Einkaufsbedingungen mit Stand Januar 2018.
EU-Konformitätserklärung / European Union conformity explanation
Für das nachfolgend bezeichnete Erzeugnis / For the following designated product
Zeitsteuerung vom Typ / Time control type
MAXI 3300 / 3500 MC (SMD)
wird hiermit bestätigt, dass die Bauart, in der von uns in Verkehr gebrachten Ausführung, den unten genannten Normen
entspricht.
It is hereby confirmed, that the construction in that execution brought by us in traffic corresponds to the standards specified
down.
Diese Erklärung gilt für alle Geräte, die nach den beiliegenden technischen Unterlagen, welche Bestandteile dieser Erklärung
sind, hergestellt werden.
This explanation applies to all devices, after the enclosed technical documents, which are components of this explanation,
are manufactured.
Einschlägige EG-Richtlinien / Relevant EC guidelines
RoHS-Richtlinie 2011/65/EU / RoHS Directive 2011/65 / EU
1. 2006/95/EG (Niederspannungsrichtlinie)
2006/95/EG (low-voltage guideline)
geändert durch
changed through
2014/35/EU
2. 2004/108/EG (EMV-Richtlinie)
2004/108/EG (EMV guideline)
geändert durch
changed through
2014/30/EU
Angewendete harmonisierte Normen:
Applied one harmonized standards:
EN 60335-1 von 01/2012 (Sicherheit)
EN 60335-1 from 01/12 (security)
EN 55022 von 12/11 (Emissionen)
EN 55022 von 12/11 (emissions)
EN 61000-3, Teil 2 + 3 von (03/2015 und 03/2014) (Emissionen)
EN 61000-3, Teil 2 + 3 von (03/2015 und 03/2014) (emissions)
EN 61000-6, Teil 1 + 2 von (10/2007 und 03/2006) (Immunität)
EN 61000-6, Teil 1 + 2 von (10/2007 und 03/2006) (immunity)
Diese Erklärung ist bindend für den Hersteller
This declaration is binding on the manufacturer
Manfred Holtkamp Elektronik GmbH
Südstraße 40 in 49084 Osnabrück
abgegeben durch:
Signature:
M. Hashemizadeh (EMV-Beauftragter)
..........................................
Osnabrück, den 20.04.2016

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 4 -

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 5 -
Inhaltsverzeichnis
1 Legal information.........................................................................................................................................................................6
2 Warranty ................................................................................................................................................................................6
3 Safety notices ..............................................................................................................................................................................6
4 Notes on cleaning and maintenance .........................................................................................................................................6
4.1 Change battery ..................................................................................................................................................................6
5 Devicespecicdata ....................................................................................................................................................................7
6 General data ................................................................................................................................................................................7
7 Illustrations ................................................................................................................................................................................8
7.1 Illustration of the device......................................................................................................................................................8
7.2 Illustration of electronic.......................................................................................................................................................9
8 Installation ..............................................................................................................................................................................10
8.1 Installation notes...............................................................................................................................................................10
8.2 Mounting notes.................................................................................................................................................................10
8.3 Monting instructions..........................................................................................................................................................10
8.4 Electrical connection ........................................................................................................................................................11
8.5 Operatingthersttime .....................................................................................................................................................12
9 Specications ............................................................................................................................................................................13
10 General card ..............................................................................................................................................................................14
11 Programming .............................................................................................................................................................................14
11.1 Methodofprogramming ...................................................................................................................................................14
11.2 Time/pricemenu...............................................................................................................................................................15
12 Congurationmenu...................................................................................................................................................................17
12.1 Mechanical singel coin tester (MMP)................................................................................................................................17
12.2 Electronicmulticointester(EMP) ....................................................................................................................................18
13 Basic settings ...........................................................................................................................................................................21
14 Enquiry card .............................................................................................................................................................................22
15 Statistics ..............................................................................................................................................................................23
15.1 Delete of statistic values...................................................................................................................................................23
15.2 Enquire of statistic values.................................................................................................................................................23
16 Non-programmable special equipment ...................................................................................................................................24
16.1 Contactor 2 x 20 A............................................................................................................................................................24
16.2 Connectivityfortimestop .................................................................................................................................................24
16.3 Powerdependingtimestop.............................................................................................................................................24
16.4 Potential free relay contact ..............................................................................................................................................24
16.5 Key switch for free use ...................................................................................................................................................24
16.6 Connectivity for delete button...........................................................................................................................................24
16.7 Connectivity for cleaning button .......................................................................................................................................24
16.8 Shorttimeimpulseforwashingmachinedooropening...................................................................................................24
17 By malfunctions.........................................................................................................................................................................25

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 6 -
3 Safety notices
The coin boxes are built according to the prior art and the reco-
gnized safety rules.
Nevertheless,itsusethreatstolifeandlimboftheuserorthird
parties,orcausedamagetothedeviceorotherequipmentdu-
ring use. Use the device only in perfect condition, and intended,
safetyandtheriskofdanger,incompliancewiththeinstruction
manual! Do immediately eliminate particular disorders, which
mayaectsafety!Alwayskeeptheoperatinginstructionsdirectly
tothecoinbox!Note,inadditiontotheuserguide,thegenerally
applicablelegalandothermandatoryregulationsrelevanttoac-
cidentpreventionandenvironmentalprotection!
Performnochangesand/ormodicationstothecoinboxwithout
approvalofthemanufacturer!Sparepartsmustmeettherequi-
rementsspeciedbythemanufacturer.Thisisguaranteedonly
fororiginalspareparts.Doobservetheintheusermanualspeci-
edorprescribeddeadlinesforrecurringmaintenanceintervals!
1 Legal information
Allrightsreserved.Nopartofthismanualmaynotbereproduced
orcopiedinanyformwithoutpermissionofHoltkampElektronik
GmbH.Therightsforcontainedsoftwareincontrolandmemory
blocksareexclusivelyfromthe manufacturer.Thereadingand
copyingoftheprogramcontentisstrictlyprohibited.
TheHoltkampElektronikGmbHisnotliabletothepurchaserof
this product or third parties for damages, losses, costs or ex-
penses caused by the buyer or any third party due to accident,
misuseorunauthorizedalterations,repairsorimprovements.
TheHoltkampElektronikGmbHshallremainliableforanyloss,
costs,disruptionsorconsequentialdamagesthatresultfromthe
use of the control.
The technical data are up to date. Misprints, errors and modi-
cations excepted. Older manuals are no longer valid with the
publicationofthismanual.
ATTENTION:
The installation must be performed by authorized
personnel! Therefore, make sure, that the installation
is carried out by an electronics specialist! Since this
isastationarydevicewithmain-sidexedconnecti-
on, a circuit breaker must be installed on the instal-
lation side!
4 Notes on cleaning and maintenance
Thedeviceismostlymaintenance-free.Bypoorcoinacceptan-
ce,thecoinrunwayoftheelectronicmultiplecointestercanbe
cleanedwithadampclothorbrushto remove any dustor de-
posits. The metal casing can be cleaned with a damp cloth or
a cleaning agent which can be dissolved in water. Do not use
underanycircumstances, thinners, petrol,acetoneorscouring
cleaning agents.
2 Warranty
Onthefunctionofthedeviceisgrantedforaperiodof12months.
Thewarrantyislimitedsolelytotechnicaldefectsoftheunit,it
can´tbeacceptedfurtherclaims.Furtherapplyourgeneralterms
and conditions, stand of June 2011, for products and services of
theelectricalindustry(ZVEI)-alsoseewebsite:www.holtkamp.
de.
Anyliabilityextinguishedbythemanipulationofthedevice.
Doprovideforthesafeandenvironmentallyfriendlydisposalof
plasticpartsandelectronicreplacementparts!
Themanufacturerisnotliablefordamagecausedbyimproper
use.Theuserbears therisk.Intendeduse alsoincludescom-
pliancewiththeoperatinginstructionsandcompliancewiththe
inspectionandmaintenanceconditions.
4.1 Change battery
The MAXI has a battery type CR 2032 for the storage of stati-
stics, which should be changed every 2 years.
Ifthisdoesnothappen,thelossofthestatisticsmustbeexpec-
ted.
Method:
The battery must only be replaced by an electrician!
SwitchotheelectricalvoltageattheMAXI. Removethefront
panel. Solder the old battery and replace it with a new battery.
Make sure that the new battery is properly soldered and that no
are produced solder joints. It is important to switch the device
on again after replacing the battery. If this does not, the battery
emptieswithinafewdays!
IftheDIPpointsash,calluptheaccountingstatisticsmenuat
once to delete this error.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 7 -
5 Devicespecicdata
After switching on the electricity on the display appears for
approx.2seconds:HoltkampXLX.x,belowinthesecondrow:
T-Timer.Thisisinformationabouttheusedsoftwareversion(X.x)
aswellastheoperatingtypeoftheMAXI(T-Timer).
Lockingno.(embossedonthekey)
Operating type and software version
(Thedisplayappearsitasnumber,2secondsafteractivate)
Serialnumber(written on the type plate)
Commission
Trader
6 General data
Casingmaterial Galvanisedsteelplate1,5mm
Casing color PowdercoatedwhiteRAL9016
Design foil color yellow-orange
Customdesignfoil on request
Dimensions H255mmxW170mmxT135mm
Weight ca. 4,0 kg
Temperaturerange 0° TO 50°C
Power supply 230Vor24V,50/60Hz
Switched power 6,3Abycosphi=1;230V/24V
Power absorption 3,3 VA
Protection class I by 230 V~ or. III by 24 V
Protection typer IP20
FusecircuitboardSI1 50mAT
Attention: Fuses may only be replaced with the same value
Productiontechnical as well as technical advancements reserved.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 8 -
7 Illustrations
7.1 Illustration of the device
1 Casing
2 Coin tester
3 Coin slot
4 Coin reject button*
5 Coin return
6 Coin bag
7 Lock
8 Coinremove
9 Card slot for general card
10 Frontplate
11 LEDdisplay
12 Design foil (Standard-Ausführung)
* (Special equipment) The coin reject button can be used also as door opener.
1
2
3
4
5
6
7
9
10
11
12
8

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 9 -
7.2 Illustration of electronic
1 Connection for coin tester
2 Connectionforremotestartbutton
3 Connectionfortimehold;cleaningbuttonordooropener
4 Connection for delete button
5 Jumper“LöFrei”
6 Connectionforgeneral-/equirycard
7 Connection for bypass swithcn
8a Additional relay for 110% disconnection
8b Main relay
8c Run-out relay
9 Electrical connection
10 FusePCB
specialequipment
abc
NLL` Lü
1
2 3 4 5
6
7
8
9
10
Circuit board MC-Gen2-V100; 230V~

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 10 -
●Drill the holes and insert suitable dowels. Through
theholesonthedevicebottomconnectuptheelectricity.
After electrical connection you can bolt on the casing. Now
restoretheelectricalplug-and-socketconnectiontothefront
plate.Fittingthefrontplateandboltittogether.Insertthe
coinbox,ttingthecoinremoveandboltwiththelock.
8 Installation
8.1 Installation notes
Throughhighqualitymicro-electronicsisthedeviceabletoreach
a high standard of reliability in the daily use. Only if the installati-
on has been professionally carried out can the device be guaran-
teed. Please note during the installation, ...
● Onlyauthorizedandqualiedelectricianscarryoutthein-
stallationcomplyingwiththevalidVDE–regulations.
● Thattheoorcoveringisanti-staticandconductorcapable,
to ensure a minimum of static change and so redu-
cing the danger to the electronics.
● Amalfunctionorbreakdownofthedevicecanbecaused
by the switching sparks of the relay contacts. To reduce these
sparksappropriatesuppressioncombinationsmustbein-
cludedparalleltotheprotectioncontacts.RCcombinations
forsparksreducingareonlyaectivebydirectparallelswit-
ching of the relay contacts.
●That the screened control and data cable are laid separa-
telyfrommainscables.
● Thatthefeedlineareused,whichisfromabigcrosssec-
tiontosupplyboththeMAXIandtheattachedelectricconsu-
mer.Itshouldbeusedancrosssectionfrom1,5mm²atthe
minimum.
8.2 Mounting notes
● Thisdevicemayonlybemountedonasuitablesurface.
● Thedevicemustbesucientlysecured,takeintoconsi-
derationtheweightoftheinsertedcoins.Thereare3holesin
thebackofthecasingtoaccomplishthemountingprocess.
Screws and dowels are included by delivery.
● The device must be mounted horizontally and verti-
callytoguaranteeaawlessfunctionofthecoinreceiver.
Thatmeanstheangleofthedevicecanonlybemaximum
2 º, sloping forward or backward, as well as to the right or
the left.
● Theinputcablesarexedbythreedrilledholesintherear
wallorbythreebigdrilledholesinthecasingbottom.There
arettingswithmetricthread(M20)necessary,ifthedevice
cablingaremadethroughthedevicebottom.Theseare
not include by delivery.
● Choosethecablecross-sectionofthefeedlinebigenough!
Attend thereby the connected electrical load. At-
tend to the VDE guidelines.
8.3 Monting instructions
● TheMAXIisconformwiththetypeofprotectionIP20and
maybeappliedindryroomsonly.
● Theelectriccurrentsupplymustbeswitchedobythrowof
the correspondent disconnecting switch, fuse or through
activatingoftheFIprotectiveswitch.
● Openthelockofthecoinremoveandgetito.
● Unxthetwoscrewsofthefrontplateandliftosofar,that
the electrical plug-and-socket connection can be deduc-
ted.Deductedtheplug-and-socketconnectionandremove
thefrontplatecompletely.
●The wall plate horizontal and vertically align with the help
of a level.
The tilt angle can only be 2° now mark the drilled holes.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 11 -
Connection 230V~ Connection 24V~
MAXI 3300MC MAXI 3300MC
230V~ 24V~
L2 PE N L3 L2 U0U1
LH NLU0U1
violet
Earth wire
green-yellow
blue
black
LN
brown
L1
LH
violet
Earth wire
green-yellow
blue
black
LN
brown
L1 PE
Remotestart Remotestart
8.4 Electrical connection
The electrical connection can only be carried out by
authorizedandqualiedpersonnel!
The electrical connection has to be carried out by the local VDE
regulations.Withapermanentconnection,anallpolemainsse-
paratorwithatleast3mmcontactgapmustbeused.
Beforestartingtheelectricthecorrespondingcircuitmustbedis-
connected. Shut down the mains input by activating the sepa-
rator switch, remove the fuse or release the main safety fuse.
Mainsandlowvoltagecablemustbespacedapart.Lowvoltage
cables should be generally spaced as screened cables.
Control cable and remote
start connection have to be
kept away from each other.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 12 -
8.5 Operatingthersttime
IftheMAXIisinstalledcompletely,youcantakeintooperationby
switching on the circuit.
As soon as the circuit is activated, appears in the display an
information about the operation mode of you MAXI and about
the used software. After that appears in the display a zero. The
MAXIisnowreadyforoperationandcannowbeprogrammedas
youlike.Toensure,thattheprogramminghasbeencorrect,you
shouldmakeadetailedtestrun.
After this test run all counters should be deleted to receive a
correct account.
0.5 0.10
0.10 -
0
Connection 230 V
Remote start
(potential free)
March 2003 110% shutdown
according to standard EN 60335-2-27/A11 (VDE 0700
part 27). As of May 2003 are all MAXI devices automati-
cally made according to the regulations above with re-
commended shutdown.
EN60335-2-27:
ThePCBofMAXIisprovidedwitha110%-disconnection.Itme-
ans,thatanemergencystoptimeriscontrolledbyathirdrelay
onthePCB.Itguaranteestheswitchingoofthesunbed,ifthe
mainrelayisnotswitchingoonce,aftertheexpiredtime.
8.6 The function run
-Insertcoins,tillthecompletepriceispaid.Theamount,which
mustbepaid,appearsinthedisplaybackwardsrunning.
-Thepre-runtimeruns.Inthedisplayappearsthemaintime.
-Assoonasthepre-runtimeisrunoutortheremotestarthas
beenactivated,themaintimebegins.Thisisshownwithaas-
hing point in the display.
-Ifthemaintimehasrun,therun-outtimebegins(coolingdown
phase). In the display appears a bar.
-Afterendoftherun-outtimetheMAXIisfreeforthenextpay-
ment.Inthedisplayappears:

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 13 -
MAXI 3300MC Gen. II
controls 1 device (e.g. sun bed)
Electronicmultiplecointester
Mechanic single coin tester
Pre-runtime
Maintime(1min.–9h.59min.)
Run-outtime
Maximumtime
LEDdisplay3-digitys
Programmingwithgeneralcard
Price setting (coin value)
Minimuminsert
Shorttimesale
Money counter
Operating hour counter
Service hour counter
Customercounter
Token counter (only by EMP)
Contactor
Timestop,cleaningbutton,dooropener
Remotestart
Generalcard(owner-oncepercommission)
Statistic enquiry card (owner + personnel)
Customerdesignfoil on request
Standard Special equipment
Productiontechnical as well as technical advancements reserved.
9 Specications

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 14 -
10 General card
Thegeneralcardisforprogrammingofthestandardandspecial
functions.Thegeneralcardisincludedoncepercommission.
= TheprogrammingmodewillbepressedPROG
button.IfthePROGbutton ispressedrepeatedly
thenormalmodeisactivated.
= By pressing the NEXT button in the pro-
grammingmode,thenextprogrampositioniscall
up.WithNEXTbuttonthestatisticmenuiscall
upandtherststatisticpositionappears.
BypressingNEXTbuttonwillbepressedagain,
thenextstatisticpositionisshown.IsthePLUS
andMINUSbuttonwillbepressedatthesame
time,theshownstatisticisdeleted.
= By pressing PLUS button the values, which
should be adjusted, will be increased.
= By pressing MINUS button the values, which
should be adjusted, will be decreased.
11 Programming
11.1 Method of programming
1. Takeothecoinremove.
2. Push in the general card in the card slot with the buttons
upwards.
3. Press PROG buttonatonce.Youarenowintheprogram-
mingmode(Time/Pricemenu).
4. LeavethroughtheprogrammingpositionswithNEXTbut-
ton (press the button longer for backwards)
5. Atrstthepositionnumberwillbeshownforashorttime,
thanthevalue,whichhastobeprogrammed.
PROG
NEXT
+
-
1
PROG 1
PROG
PROG
1.30
press
PROGbuttonProgrammingbuttoncurrentvalue newvalue
2.00
Pre-run time
6. WithPLUSorMINUSbuttonyoucanchangethevalues.
7. Press the PROG button twiceformemoryoftheprogram-
mingandreturntotheoperatingmode,ornoactivatingfor
longer as 30 seconds.
Example for programming
Pushinthegeneralcardinthecardslot!

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 15 -
Run-out time
Therun-out timeis theadditionalruntime ofsun bed fanafter
maintimehasrunout.Inthisoperationmodeisonlytherun-out
relayactivated.Itisadjustablein5-secondstepstomax.9hours
55minutes.
Main time
The main time 1 is the operating time of connected device. It
canbe adjusted inminutesstepsto max. 9hours59minutes,
beneath10minutesinsecondsteps(only,ifthiswasactivatedin
theassembly-congurationmenu).DisplayformatseeA2(Main
timerepresentation:hoursorminutes).
11.2 Time/price menu
Intheprogrammingmodetheprogrammingpositionswillappear
inthedisplaythroughnumberandlettercombinations.
This explains the following:
Pre-run time
Thepre-runtimeisthedelaytimefrompaymenttostartofthe
connecteddevice.Themaximumis9minutes59seconds,ad-
justableinsecondsteps.Theexpirationofthepre-runtimecan
benishedwithactivationoftheremotestart.
1
2 3
45
10
Remote start
Theremotestartgivesthepossibilitytoactivatebyanexternal
button.2proceduresarepossible.Intherstcasetheleadtime
issetonlowerthen“0”.Inthiscasetheleadtimewasendedby
pressingtheremotestartandthemain-timestartsimmediately.
In the second case the lead time is set on = “0”. In this case
beginsthemain-time,rst,afteractivatingtheremotestart.This
canbecalledasaforcedremotestart.Ifthefullpricewaspaid,
itisnotpossibletopayadditionalmaintimeforsecurityreasons,
afternishpre-runtime(intanningsector).Shouldaconnected
devicebeoperatedwithoutdelayandactivatingtheremotestart,
thejumperFSmustbeactivatedon“0”.
The remote start has to be carried out, basically, poten-
tial free to the external tester on the sun bed.
Maximum time
Themaximumtimeisthelimitofthemaintime.Itisadjustable
inminutestepstomax.9hours59minutes,beneath10minutes
insecondsteps(only,ifinthecongurationmenuthepoint"SE"
wasactivatedwith"1").
The max. allowed tanning time, which the producer of
sun beds has declared, must be adjusted in the maxi-
mum time. Attention! Danger of burning!
If it is adjusted "0" minutes, this function is deactivated
and it can be paid any main time.
Price setting
Thepriceoersthepossibilitytoprogramtheamount,payable
foreachmaintime.Itisadjustablefrom0,1to99,9in0,1-steps.
Thefullpricemustbepaidtobuyeachmaintime.Unless,the
shorttimesaleisactivated(seeshorttimesale).
Service interval
The service interval 1 oers the possibility to note operating
hours. When the service hours counter reaches the operating
hours,thedisplayisashingandtheservicedateappears.The
serviceintervalisadjustabletomax.999hoursinsecondsteps.
If it is adjusted "0" hours, this function is deactivated.
Theashingcanbestoppedbydeletingoftheservice
hour counter reading.
Rest price indication
The rest price indication oers the possibility, to show in the
displaytheremainderpricethatneedstobepaidafterinsertof
minimumonecoin.Thedisplayshows"0",theremainderprice
indication is deactivated.
Thedisplayshows"1",theremainderpriceindicationisactiva-
ted.
After full payment appears in the display the purchased main
time.
A1

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 16 -
Main time presentation
The main time presentation oers the possibility, to show the
maintimeinminutesorinhoursandminutes.
Thedisplayshows"0",themaintimeappearsinhoursandminu-
tes(max.9hours59minutes).Thedisplayshows"1",themain
timeappearsinminutes(max.999minutes).
A2 b1
b2
H1
Fan pre-run
Thefanpre-runoersthepossibility,toswitchonthefanbybe-
ginningofthepre-runtime.
Thedisplayshows"0",thefanpre-runisdeactivated.
Thedisplayshows"1",thefanpre-runisactivated.
u1
Minimum insert
The minimum insert oers the possibility to convert the price,
which is adjusted under 5 the price setting, to minimum price.
Theminimumpriceistheprice,whichmustbeminimuminserted
tobuyoncethemaintime.Afterpaymentofonemaintime,itcan
bebought paritalmaintime through insertofany coins.Inthe
displaywillbeshown(from10minutes)fullminutes,butitwillbe
deductedinrealtime.Forexampleyoucanreachedatimefrom
12 minutes and 30 seconds through additional purchase. The
displayshow13minutes,buttheconnecteddeviceisactivated
for12minutesand30secondsonly.
Thedisplayshows"0",theminimuminsertisdeactivated.
Thedisplayshows"1",theminimuminsertisactivated.
Short time sale
Theshorttimesaleoersthepossibilityforactivationofpartial
maintimesalepercoininsert.Thepaymentofpartialmaintime
takesplacebyinsertingtherstcoin.
Thedisplayshows"0",shorttimesaleisdeactivated.
Thedisplayshows"1",shorttimesaleisactivated.
The program of MAXI ensures, that will be activated the
minimum insert or the short time sale only. If despite
of this one tries to activate both positions, the last acti-
vated position remains activated. The other will be
set to 0 automatically.
If neither will be activated minimum insert nor short time
sale, must be paid the full price to get the adjusted main
time. The same is true for additional purchase from time.
If the main time will be paid once, it must be paid the full
priceforanytime.
Start barrier
Thestartbarrieroersthepossibility,tobanthenewstartfrom
maintimeduringtherun-outtime.Thenewmaintimecanalsoto
bepaidduringtherun-outtime.Thepre-runtimeofthenewmain
timewillbeaccountedwiththeremainingrun-outtimeatthetime
ofpayment.Isthisfunctionisnotactivated,therun-outtimedoes
notmatter,themaintimebeginsafternishofpre-runtime.
Shouldtheforcedremotestartbeactivated(forcedremotestart
active,ifpre-runtime=0),thedevicecanbestartedwithremote
startbuttonafternishofrun-outtime.
Thedisplayshows"0",thestartbarrierisdeactivated.
Thedisplayshows"1",thestartbarrierisactivated.

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 17 -
12 Congurationmenu
The call up of this menu takes place with pressing twice the
PROGbuttononthePCB.Theleavethroughofthemenupoints
takes place with the NEXT button, the changing of the adjust-
mentswithMINUSandPLUSbutton.Intheprogrammingmode
theprogrammingpositionswillbeshowthroughnumberandlet-
tercombinationsinthedisplay.Inthefollowingthisprogramming
positionswillbeexplainedwhatthismeans.
Channel value
The adjustment of the channel values oers the possibility, to
determinethevalueoftheinsertedcoinfortheMAXIindividual.
For security reasons the modication of the facto-
ry-made adjusted channel values is only possible, if the
jumper "LöFrei" will be stucked on the PCB.
The following positions E2-E6 appears only by a MAXI with
electronicmulticointester(EMP).
E1
E6
Jumper
LöFrei
put on E6 03.5 03.5
+
-
Programmingposition current value current value
E6 is the channel value for the token. This will be adjusted facto-
ry-madeon3,5(EUR,Sfr,Nkr,Dkr...).
Should be changed this value, act as follows:
-stuckjumper"LöFrei"onthePCB(adjustedfactory-made)
- press the PROG button twice
- dial the position, which should be changed, with the NEXT button
-adjustedthedesiredvaluewithPLUSorMINUSbutton
Example:
Channel value
12.1 Mechanical singel coin tester (MMP)
If your MAXI is equipped with mechanical single coin tester
(MMP), it can identify and accept only one coin. If this coin will be
inserted,atrstitnoticedtheinsertonly,butitdonotknow,which
value the coin should have for the MAXI. This value attribution
takesplacewithprogrammingofthechannelvalue.Theidenti-
cation and value attribution happens as follows...
… in the mechanical single coin tester (MMP) … in the MAXI
1. insert the coin 2. the coin will be assigned
tothe"channel"inthe
MMP
3.the"channel"oftheMMP
will be assigned to the
"channel"oftheMAXI
4.the"channel"oftheMAXI
will be assigned to the
programmedvalue
(factory-madeorindividual)
EUR 0,50 1 E1 e. g. 01,0

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 18 -
12.2 Electronic multi coin tester (EMP)
If your MAXI is equipped with an electronic multi coin tester
(EMP), it can identify and accept up to 6 several coins. If a coin is
inserted,atrstitnoticestheinsertonly,butitdon´tknow,which
value the coin should have for the MAXI. This value attribution
takesplacewithprogrammingofthechannelvalue.
Theidenticationandvalueattributionhappensasfollows...
… in the mechanical single coin tester (MMP) … in the MAXI
1. insert the coin 2. the coin will be assigned
tothe"channel"inthe
MMP
3.the"channel"oftheMMP
will be assigned to the
"channel"oftheMAXI
4.the"channel"oftheMAXI
will be assigned to the
programmedvalue
(factory-madeorindividual)
EUR 0,50 1 E1 z.B.0,50EUR(factory-m.)
EUR 1,00 2 E2 z.B.1,00EUR(factory-m.)
EUR 2,00 3 E3 z.B.2,00EUR(factory-m.)
EUR 0,20 4 E4 z.B.0,20EUR(factory-m.)
- 5 E5 z.B.free(factory-m.)
Holtkamp-Standard-Token 6 E6 z.B.3,50EUR(factory-m.)
The allocation of the channels to the thrown in coins can be
inferredfromthestickeronthesidecoveroftheelectronic
multiplecointester.Thereisthepossibilityofclosingindividual
channels. Thus the coin acceptance is blocked.
1 - 8 9 - 16

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 19 -
Second interval
● Thedisplayshows"0“,maintimerunoutinminuteinterval
● Thedisplayshows"1“,maintimerunoutinsecondinterval
Is"SE"activatedwith"1",themaintimecanbeadjustedjuston
max.9minutes59seconds.Shouldappearalongermaintime
insecondsinthedisplay,itmustbeactivatedthereforethemain
timeindication"A2"intheprogrammingmenu(A2=1).Thanit
canappearsthemaintimeupto999seconds.
Basics to the settings:
Yourcointesterenablesforthemostcoins3severalacceptan-
cebehaviors.Narrow,middleandwide.Thisbehaviorshouldbe
alignedindividualtothepersonalneeds.Withanarrowbehavior
yourefusetoacceptthemostbadmoney,butthroughverystrict
measurements the desired coins will also be defeated.A wide
behavior accepts more bad money, but it is also troule-free in
handling with desired coins.
Factory-madeareall3behavioracceptancesfortheindivi-
dualcoinsactivated.Factory-madeareactivatedfor0,50
EURO, 1,00 EURO and 2,00 EURO. The coin 0,20 EURO
andthestandardtokenareblockedfactory-made.
The correlation of the channels to the thrown in coins you can
alsoseeonthelabelonthecoverfromthecointester.Itispos-
sible, to blocked several coins. Thereby the coin acceptation is
refused.
9 10 11 12 13 14 15 16
2,0 EURO
wide
yes
2,0 EURO
middle
yes
0,5 EURO
wide
yes
0,5 EURO
narrow
yes
1,0 EURO
narrow
yes
Teach-
Funktion
no
EURO
yes
2,0 EURO
narrow
yes
1 2 3 4 5 6 7 8
Token
Standard
no
0,2 EURO
wide
no
0,2 EURO
middle
no
Token
Contours
no
0,5 EURO
middle
yes
1,0 EURO
wide
yes
1,0 EURO
middle
yes
Aktivation
coin
acceptance
yes
InthebasicadjustmentoftheEMPthechannelsfor0,2Euro
and the tokens are closed.
You can enable and disable individual coin types with the help
ofcertainDIPswitchcombinations.Thereare16DIPswitches,
whicharenumberedaftertheupperimaging.
Notes for the electronic multi coin tester (EMP)
YourMAXIisequippedwithanelectronicmulticointester.Plea-
se consider the following noticing:
● Wellworn,dirty,damaged,falseandforeigncurrencycoins
will not be accepted.
●If an apparently good coin is not accepted, please use ano-
ther coin.
● Neverinsertmorethanonecoinatthesametime.
● Pressthecoinreturnbuttontoreleasejammedcoins.
● Whennocoinsareaccepted,ashort(5seconds)breakof
the power input often helps.
● Onlyusetheelectroniccointesterbetweentemperatures
of0ºC–50ºC.
● Temperaturesuctuationsandstrongmagneticeldscould
aecttheacceptancebehaviourofthecointester.
● Theremovingorinstallingofanelectronicmulticointester
maynotbecarriedoutbyactivatedoperatingvoltage.
SE FE
Remote start
● Thedisplayshows"0",theremotestartisdeactivated.The
purchasedmain timestartedeither directly(ifthe pre-run
timeisadjustedon"0"orafternishofthepre-runtime.
● The display shows "1", the main time starts until activa-
tion the remote start button. (It starts also, if a pre-run
time is programmed and nished. With the remote start
buttonthepre-runtimecanbecutshortandthemaintime
starts directly.)

Holtkamp Electronics MAXI 3300MC english techn. stand 09.2017 4019_11.2017 V09.2019
- 20 -
Connection socket for Time stop/
Cleaning button/Door opener
short time impulse
(Special equipment)
● itisadjustableon"0","SP","Pu"or"IP"
The3functionstimestop,cleaningbuttonanddooropenershort
timeimpulsearesharethesameconnectiononthePCB,soit
can be activated one of there functions only.
The desired function must be declared by order and it
will be adjusted factory-made.
● Thedisplayshows"0",theconnectioniswithoutfunction
● Thedisplayshows"SP",thetimestopisactivated(special
equipment).Themaintimerunsonly,iftheconnectionisbrid-
ged.Alsobystoppedmaintimethemainandsafetyrelay
where be switched on. Operation and servicehour counter
countsalsobyactivatedtimestop
● The display shows "Pu", the cleaning button is activated
(specialequipment).Afternishofthemaintimethecleaning
timewillbeactivated,inthedisplayashes"---"(itcanbe
paidanylongermaintime).Withthatthecleaningstawas
calledupon,tocleanthesunbed.Aftercleaningthestaac-
tivatesthecleaningbutton,theindication"---"isnished.
An
LS
● Thedisplayshows"IP",thedooropenershorttimeimpul-
seisactivated(specialequipment).Thereisaspecialfunction
forwashingmachinedooropening.Ifthemaintimeisrunning
out,thewashingmachineisswitchedstrain-freeandbyany
machinesyoucannotopenthedoorfortakeoutthelaundry.
● Ifthefunction"IP"isactivated,themainrelayisactivated
for 30 seconds after pressing the button which is attached in
the casing.
● Thedoorcanopennow.Thefunction"Dooropener"isnow
blocked for 60 seconds. Operation and service hour counter
countsduringthedooropenertime.
Delete blocking time
● adjustablefrom0to4:15minutes
Special for operation of washing machines: depending on the
constructionoftheplantthemaintimewilldeleted,ifoneopens
thewashingmachinedoor.Ifadjustedthedeleteblockingtime
on a value bigger than "0", the washing machine door can be
openedafterthestartforashorttime,toinsertforgottenlaundry,
withoutdeletingmaintime.
YoucanleavethemenubypressingPROGbuttononceorno
activatingbuttonanytime.
Table of contents
Other Holtkamp Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Digital Equipment
Digital Equipment VT520 Installation and operating information

Mitsubishi Electric
Mitsubishi Electric GOT 1000 Series General description

Lathem
Lathem PCPROX quick start guide

ABB
ABB SACE Tmax T7D/PV installation instructions

Furuno
Furuno DP-6 Operator's guide

BRUEL & KJAER
BRUEL & KJAER 3639-E Product data