Holtkamp VENUS 6600 XL User manual

Operating instruction
VENUS 6600 XL
Chip card system

Important: For safe and proper use, read the instructions for use and further product-related documents carefully and keep
it for later use!
For errors, technical errors, printing errors and incompleteness, we assume no liability.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 3 -
Conformity explanation
Südstraße 40 / D-49084 Osnabrück
info@holtkamp.de /
www.holtkamp.de
Telefon: +49 541 97120-0, Fax: +49 541 97120-40
Geschäftsführung: Magnus Michael, Uwe Staudinger; Sitz der Gesellschaft: Osnabrück, AG Osnabrück HRB 213567
Banken: Deutsche Bank Osnabrück, IBAN: DE28 2657 0090 0039 5251 00; SW IFT/BIC: DEUTDE3B265
Die Lieferung erfolgt zu unseren Allgemeinen Geschäftsbedingungen mit Stand Juni 2011 nach ZVEI unter Einbeziehung der Softwareklausel
zur Überlassung von Standard-Software als Teil von Lieferungen mit Stand April 2012 nach ZVEI.
Zusätzlich gelten unsere Vertragsbedingungen „Hardware/Schaltplan/Layout“ und „Auftragsfertigung“.
Es gelten unsere Einkaufsbedingungen mit Stand Januar 2018.
EU-Konformitätserklärung / European Union conformity explanation
Für das nachfolgend bezeichnete Erzeugnis / For the following designated product
Zeitsteuerung vom Typ / time control type
VENUS 6600/XL
mit Notaus-Timer (110%)-Funktion / with emergency stop timer (110%) function
wird hiermit bestätigt, dass die Bauart, in der von uns in Verkehr gebrachten Ausführung, den unten genannten Normen
entspricht.
It is hereby confirmed, that the construction in that execution brought by us in traffic corresponds to the standards specified
down.
Diese Erklärung gilt für alle Geräte, die nach den beiliegenden technischen Unterlagen, welche Bestandteile dieser Erklärung
sind, hergestellt werden.
This explanation applies to all devices, after the enclosed technical documents, which are components of this explanation,
are manufactured.
Einschlägige EG-Richtlinien / Relevant EC guidelines
RoHS-Richtlinie 2011/65/EU / RoHS Directive 2011/65 / EU
1. 2006/95/EG (Niederspannungsrichtlinie)
2006/95/EG (low-voltage guideline)
geändert durch
changed through
2014/35/EU
2. 2004/108/EG (EMV-Richtlinie)
2004/108/EG (EMV guideline)
geändert durch
changed through
2014/30/EU
Angewendete harmonisierte Normen:
Applied one harmonized standards:
EN 60335-1 von 01/2012 (Sicherheit)
EN 60335-1 from 01/2012 (security)
EN 55022 von 12/2011 (Emissionen)
EN 55022 von 12/2011 (emissions)
EN 61000-3, Teil 2 + 3 von (03/2015 und 03/2014) (Emissionen)
EN 61000-3, Teil 2 + 3 von (03/2015 und 03/2014) (emissions)
EN 61000-6, Teil 1 + 2 von (10/2007 und 03/2006) (Immunität)
EN 61000-6, Teil 1 + 2 von (10/2007 und 03/2006) (immunity)
Diese Erklärung ist bindend für den Hersteller
This declaration is binding on the manufacturer
Manfred Holtkamp Elektronik GmbH
Südstraße 40 in 49084 Osnabrück
abgegeben durch:
Signature:
M. Hashemizadeh (EMV-Beauftragter)
..........................................
Osnabrück, den 20.04.2016

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 4 -
Content
1 Legal information......................................................................................................................................................................... 5
2 Warranty ................................................................................................................................................................................5
3 Safety notices ............................................................................................................................................................................. 5
4 Devicespecicdata .................................................................................................................................................................... 5
5 Specications .............................................................................................................................................................................. 6
6 General details ............................................................................................................................................................................. 6
7 Illustrations ................................................................................................................................................................................7
7.1 Illustration of device............................................................................................................................................................ 7
7.2 Illustration of electronic....................................................................................................................................................... 8
8 Installation ................................................................................................................................................................................9
8.1 Installation notes.................................................................................................................................................................9
8.2 Mounting notes................................................................................................................................................................... 9
8.3 Montageanleitung............................................................................................................................................................... 9
8.4 Electrical connection.........................................................................................................................................................10
8.5 Operatingthersttime ..................................................................................................................................................... 11
8.5.1 LED operating light ..................................................................................................................................................... 11
9 Specications ............................................................................................................................................................................ 12
10 Chip card types.......................................................................................................................................................................... 13
11 General at programming ........................................................................................................................................................... 13
11.1 Explanation of the program positions ............................................................................................................................... 13
11.2 Basic programming by operation mode „Timer” (Factory settings)...............................................................................................14
11.2.1 Time/price menu ......................................................................................................................................................... 14
11.2.2 Clock menu................................................................................................................................................................. 17
11.2.3 Congurationmenu .................................................................................................................................................... 18
11.2.4 Buscongurationmenu .............................................................................................................................................. 20
12 Chip card revalue....................................................................................................................................................................... 21
12.1 Personnel revalue mode...................................................................................................................................................21
13 Statistics ..............................................................................................................................................................................22
13.1 Explaining the statistics values......................................................................................................................................... 22
13.2 Enquiring the statistic values............................................................................................................................................ 22
13.3 Cancelling the statistic values .......................................................................................................................................... 23
13.5 Enquiring the failure statistics........................................................................................................................................... 24
13.6 Readout the code ............................................................................................................................................................. 24
14 Not programmable special equipments ................................................................................................................................. 25
14.1 Electric contactor 2 x 20 A or 4 x 20 A optionally.............................................................................................................. 25
14.2 Extra connection for time stop.......................................................................................................................................... 25
14.3 Power depending time stop.............................................................................................................................................. 25
14.4 Extra connection for cleaning button ................................................................................................................................ 25
14.5 Internal short time impulse for washing machine door opening ....................................................................................... 25
14.6 Potential free relay contact............................................................................................................................................... 25
14.7 Connection possibility for cancel button ............................................................................................................................ 25
14.8 Connection option for delete button..................................................................................................................................25
14.9 Remote indication incl. connection possibility in VENUS with or without remote start..................................................... 26
15 By malfunctions ........................................................................................................................................................................ 27

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 5 -
1 Legal information
All rights reserved. No part of this manual may not be repro-
duced or copied in any form without permission of Holtkamp
Elektronik GmbH. The rights for contained software in control
and memory blocks are exclusively from the manufacturer.
The reading and copying of the program content is strictly pro-
hibited. The Holtkamp Elektronik GmbH is not liable to the
purchaser of this product or third parties for damages, los-
ses, costs or expenses caused by the buyer or any third party
due to accident, misuse or unauthorized alterations, repairs or
improvements.
The Holtkamp Elektronik GmbH shall remain liable for any loss,
costs, disruptions or consequential damages that result from the
use of the control.
The technical data are up to date. Misprints, errors and modi-
cationsexcepted.Oldermanualsarenolongervalidwiththe
publication of this manual.
ATTENTION:
The installation must be performed by authorized
personnel! Therefore, make sure that the installati-
on is carried out by an electronics specialist! Sin-
cethisisastationarydevicewithmain-sidexed
connection, a circuit breaker must be installed on
the installation side!
4 Devicespecicdata
After switching on the electricity on the display appears for
approx. 2 seconds: Holtkamp XXL X.x, below in the second
row: T-Timer. This is information about the used software version
(XX.x) as well as the operating type of the VENUS (T-Timer).
These details are subject of the advanced development of the
VENUS and your order. For further questions and orders these
details will constitute an advantage. Please note all the abbrevi-
ationsappearingonthedisplay,denitely,foranyothertechnical
requests, in the following list.
2 Warranty
On the function of the device is granted for a period of 12 months.
The warranty is limited solely to technical defects of the unit, it
can´t be accepted further claims. Further apply our general
terms and conditions, stand of June 2011, for products and
services of the electrical industry (ZVEI) - also see website: www.
holtkamp.de.
Any liability extinguished by the manipulation of the device.
3 Safety notices
The coin/chip card boxes are built according to the prior art and
the recognized safety rules.
Nevertheless, its use threats to life and limb of the user or third
parties, or cause damage to the device or other equipment du-
ring use. Use the device only in perfect condition, and in-
tended, safety and the risk of danger, in compliance with the
instruction manual! Do immediately eliminate particular dis-
orders,whichmayaectsafety!Alwayskeeptheoperating
instructions directly to the coin box! Note, in addition to the
user guide, the generally applicable legal and other mandato-
ry regulations relevant to accident prevention and environmental
protection!
Performno changesand/ormodications tothecoin/chip card
box without approval of the manufacturer! Spare parts must meet
therequirementsspeciedbythemanufacturer.Thisisguaran-
teed only for original spare parts. Do observe the in the user
manualspeciedorprescribeddeadlinesforrecurringmain-
tenance intervals! Do provide for the safe and environmental-
ly friendly disposal of plastic parts and electronic replacement
parts! The manufacturer is not liable for damage caused by
improper use. The user bears the risk. Intended use also inclu-
des compliance with the operating instructions and compliance
with the inspection and maintenance conditions.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 6 -
5 Specications
After switching on the electricity on the display appears for
approx. 2 seconds: Holtkamp XL X.x, below in the second row:
T-Timer. This is information about the used software version (X.x)
as well as the operating type of the VENUS (T-Timer). These
details are subject of the advanced development of the VENUS
and your order.
Locking no. (embossed on the key)
Operating type and software version
(The display appears it as number, 2 seconds after activate.)
Serial no. (written on the type plate)
Commission
Trader
For further questions and orders these details will constitute an
advantage. Please note all the abbreviations appearing on the
display,denitely,for anyothertechnicalrequests,inthe follo-
wing list.
Casing material galvanised steel plate 2 mm
Casing color powder coated white RAL 9016
Dimensions h 255 mm x w 120 mm x d 135 mm
Power supply 230 V or 24 V, 50 / 60 Hz
Switched power 6,3 A by cos phi = 1
Power absorption 10 VA
Cable entrance from below
Temperature range 0°C - 50°C
Protection class I by 230V~ and/or III by 24V~
Protection type IP X0
Weight (with empty coin-bag) app. 3 kg
Fuse circuit board SI 1 100mA T
Fuse main relay SI 2 6,3A MT
Fuse run-out relay SI 3 6,3A MT
Attention: Fuses may only be replaced with the same value
We reserve the right to technical changes in the production and technical developments.
6 General details

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 7 -
1 Casing
2 Frontplate with foil keyboard
3 Lock
4 LCD display
5 RESET-; PLUS; -OK button
6 Short manual
7 Card slot
1
2
3
4
5
6
7
7 Illustrations
7.1 Illustration of device

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 8 -
7.2 Illustration of electronic
1 Serial interface
2 Battery
3 Connection for serial remote display
4 Connection for bridge switch
5a Additional relay for 110%-disconnection
5b Main relay
5c Lead relay
6a Fuse main relay
6b Fuse lead relay
7 Power connection
8 Connection for potential free relay
9 PCB fuse
10 Connection for foil keyboard
11 Connection for chip card contact unit
12 Connection for chip card reject
13 Connection for external timer
14 DIP switch no. 1-4
15 Connection for remote start
16 Connection for time hold/cleaning button
Special equipment
PCB XL2_V021 230V~
Jp FS = 0 Jp FS =
standard
Jumper remote start (FS):
without function
abc
ab
12 13 14 15 16 1
2
3
4
5 a, b ,c
6 a, b
7
8
7
7
9
10
11

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 9 -
8.2 Mounting notes
●This device may only be mounted on a suitable surface.
● Thedevicemustbesucientlysecured,takeintoconsi-
deration the weight of the inserted coins. There are 3 holes
in the back of the casing to accomplish the mounting pro-
cess. Screws and dowels are included by delivery.
●The device must be mounted horizontally and vertically to
guarantee a awless function of the coin receiver. That
means the angle of the device can only be maximum 2 º,
sloping forward or backward, as well as to the right or the
left.
●The device must be mounted perpendicular and horizontally,
to avouch a faultless function of the coin acceptance.
That implies, the tilt angle of the device can only be maxi-
mal 2° forwards or backwards and maximal 2° to the right or
left.
● Theinputcablesarexedbythreedrilledholesintherear
wall. The device is corresponding to protection type IP 20
and may only be used in dry rooms. Choose a cable cross
section of the feed line adequate big. Attend thereby the
connected electrical load. Attend to the VDE guidelines.
8.3 Montageanleitung
● Switchothepowersupplybyswitchingoverthecorres-
ponding isolating switch, the fuse or even by tripping the
RCCB.
●Unlock the lock on the front panel and remove it to the
extent, that it is possible to remove the electrical connec-
tors.
●The device horizontal and vertically align with the help of
a level.
The tilt angle can only be 2° now mark the drilled holes.
●Drill the holes and insert suitable dowels. Make the
electrical connection through the holes in the bottom
ofthehousing.Thenxthehousingwithsuitablescrews.
Now restore the electrical connections to the front panel.
Fit the front panel and lock with the lock.
8 Installation
8.1 Installation notes
Through high quality micro-electronics is the device able to re-
ach a high standard of reliability in the daily use. Only if the in-
stallation has been professionally carried out can the device be
guaranteed.
Please consider during the installation...
● Onlyauthorizedandqualiedelectricianscarryouttheins-
tallation complying with the valid VDE–regulations.
● Bythetimerswith230V~supplyvoltageisdenitelythe
protection cable required, by the timers 24 V~ (safety ex-
tra-low voltage) protecting grounding is needed as function
earth.
●Thattheoorcoveringisanti-staticandconductorcapable,
to ensure a minimum of static change and so reducing
the danger to the electronics.
●A malfunction or breakdown of the device can be caused
by the switching sparks of the relay contacts. To reduce
these sparks appropriate suppression combinations must
be included parallel to the protection contacts. RC combi-
nationsforsparksreducingareonlyaectivebydirectpar-
allel switching of the relay contacts.
●That the screened control and data cable are laid separa-
telyfrommainscables.ThescreeningoftheVENUS electro-
nic must be one - side and laid on PE.
●That the feed line are used, which is from a big cross section
to supply both the VENUS and the attached electric con-
sumer. It should be used an cross section from 1,5 mm² at
the minimum.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 10 -
VENUS 6600/XL VENUS 6600/XL
8.4 Electrical connection
The electrical connection can only be carried out by
authorizedandqualiedpersonnel!
The electrical connection has to be carried out by the local VDE
regulations. With a permanent connection, an all pole mains se-
parator with at least 3 mm contact gap must be used. Before star-
ting the electric the corresponding circuit must be disconnected.
Shut down the mains input by activating the separator switch,
remove the fuse or release the main safety fuse. Mains and low
voltage cable must be spaced apart. Low voltage cables should
be generally spaced as screened cables.
Control cable and remote start connection have to
be kept away from each other.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 11 -
Connection 230V Remote start (potential free)
8.5 Operatingthersttime
After complete installation of the VENUS can be operated the
rsttimebyswitchingontheelectricalcircuit.Assoonaselec-
tricity has been switched on, the VENUS shows on the display
for about 2 seconds information about the operating type of your
VENUS and about the used software version (e.g. Holtkamp XL
Soft X.x T-Timer Free). The device is now ready and you can
program it as you wish. To make sure that the programming has
been properly carried out, you should make a test-run. After the
test-run the counter reading should be cancelled, to achieve a
correct account. Please make sure that your adjusted main time
is appropriated to the sun bed. Do not choose the main time too
long, because of the danger of the sun bed customer. Use the
adjustment setting, to limit the maximum time and therefore limi-
ting the maximum account of buyable main time to reduce to a
minimum the danger to the customer.
8.5.1 LED operating light
With the LED operating light one can see, at a glance, the ope-
rating stand of the VENUS. During the lead time: quick blinking;
main time: permanent light; run-out time: slow blinking.
March 2003 110% disconnection
After norm EN 60335-2-27/A11 (VDE 0700 part 27)
Beginning with 01 may 2003 all our XL devices are
equipped with the disconnection recommended by the
upper mentioned directions.
EN60335-2-27 The PCB of VENUS is provided with a 110%-dis-
connection. It means, that an emergency stop timer is controlled
by a third relay on the PCB. It guarantees the switching o of
thesunbed,ifthemainrelayisnotswitchingoonce,afterthe
expired time.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 12 -
9 Specications
VENUS 6600 XL
controls 1 device (e.g. tanning bed…)
Chip card contact unit without reject magnet
Chip card revaluation via keyboard by the owner/personnel
Pre-run time
Main time (1 min. – 1 hour 39 min.)
Maximum time
Run-out time
LCD display (time and info text display)
programming with chip card
Time memory
Price setting chip card amount
Minimum debit
Happy Hour, discount
Skintypeindentication
UV-Control tanning management
Electronic operating hours counter
Electronic service hours counter
Electronic customers counter
electronic revaluation and devaluation counter
Electric contactor
Time stop, cleaning button, delete button
Remote control
Remote start
Potential free relay contact
LED display
Design foil*
Chip card see price list chip cards
Standard version
Optional equipment / Accessories
at your choice / either - or in the standard version contain
*availableinHoltkampdesign,onrequestwithcustomerspecic
design foil available

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 13 -
10 Chip card types
There are various chip card types, to distribute to customers, as
a means of payment and to program the standard and special
functions.Thefollowingtableistoexplainthedierentchipcard
types.
Chip card type
PIN-Card
Funkcion
P11 revaluablechipcardforthenalcustomer
P14 revaluable test chip card for the service technician (seconds operating)
P15 revaluable test chip card for the service technician (minutes operating)
P33 chip card to enquire the statistics and to cancel the daily counters (for owner/personnel)
P43 chip card to enquire and cancel the statistics (for the owner only)
P53 menu programming chip card (for the owner only)
P63 clock programming chip card (for the owner only)
P73 chip card to activate the revalue function (for owner/personnel)
P83 Chipcardtoinvocatethecongurationmenu (for the owner only)
11 General at programming
The individual program positions can be accessed in quick pass
(auto repeat function), forward and backward. As following needs
to be inserted the wished program card. If you wish to pass the
menu quicker, you need to keep pushing the "OK" button. If the
"OK"button is keptpushedthemenu isowingforward.Besi-
de this you can also access the menu backward (short push on
the "OK" button, min. 300ms/max. 850 ms). If you have pushed
shortly the "OK" button, the auto repeat menu is accessed back-
wards. By short pushing of the ok button you can access the
menu again forward.
11.1 Explanationoftheprogrampositions
There are various menus in the programming mode of the VE-
NUS:the time/price menu, theclockmenu, theconguration
menu,thesummer/wintertime menu buscongurationmenu
and the UV control menu.
For the UV control menu is required an additional instruction!
Please notice that some of the program positions
must be activated, to indicate the menu point. The
menu points are recognisable by the grey back.
To program the time/price menu there are 2 possibilities:
- by opening the casing and switching on the DIP switch no. 1
(PROG), or
- by pushing in the key card type 53.
In this case the DIP switch no.3 (T063FREI) needs to be swit-
ched on, or else the card is blocked. (The switch may remain
switched on also after ending the program, you do not have to
reopen the casing for later programming).
The programming has to be done by 3 buttons on the front foil.
By RESET- and PLUS- button will be changed the values, by Ok
button will be stepped on to the next menu point.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 14 -
11.2 Basic programming by operation mode
„Timer” (Factory settings)
Your VENUS has been factory set with standard programming.
The program values are written in the appropriate displays.
11.2.1 Time/price menu:
to call with:: to quit with:
Is a chip card type 53 non-existing, you can start the menu also
with change over the DIP switches no. 1 and 3 on "ON".
Iftheprogrammingisnished,youmustchangeonlyDIPswitch
no. 1 on "OFF".
Insert chip card
type 53
Pull out chip card
type 53
The following menu options are successively programmable:
This grey deposited menu option must be only activated
inthecongurationmenu,underpaymenttype,otherwise
it does not appear by programming.
Display information Factory setting Description
Brightness 100% The brightness is used for the illumination of the display. The brightness is
adjustable in steps of 2%, from 0% to 100%.
Pre-run time 2.00 min Thepre-runtimeisthetimedierencebetweenpaymentatthecoinorchip
card timer and the start of the connecting device. It can be adjusted in steps
of 5 seconds, to a max of 9 min 55 sec. The pre-run count-down can be pre-
maturely interrupted by the remote start.
Remote start
The remote start gives the possibility to activate by an external button. 2 pro-
ceduresarepossible.Intherstcasethepre-runtimeissetonlowerthan
“0”. In this case the pre-run time was ended by pressing the remote start and
the main-time starts immediately. In the second case the pre-run time is set
on=“0”.Inthiscasebeginsthemain-time,rst,afteractivatingtheremote
start. This can be called as a forced remote start. Should a connected custo-
mer be operated without delay and activating the remote start, the jumper FS
must be activated on “0” (see picture of electronic, chap. 1.2.).
The remote start has to be carried out, basically, potential free to the
externaltesteronthesunbed.
Main time 1 0:02:00 min The main time 1 is the operating time of connected device which can be
bought with coins or a chip card. It is recallable and programmable if any
adjustmentshavebeenmadeinthecongurationmenu.Itcanbeadjustedin
1secondsteps,tomax.of99:00or1hr39min.Ifinthecongurationmodus
the menu point ”3 digits main time” is set on “Yes”, the main time can be
adjusted up to 255 min in seconds steps.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 15 -
Display information Factory setting Description
Main time 2 0:03:00 min The main time 2 is the operating time of the connected device, payable by
coins or by card. It is always active on the second step of the various pay-
ment types. It is recallable and programmable if any adjustments have been
inthecongurationmenu.Itcanbeadjustedin1secondsteps,toamax.of
99:00 min or 1 hr 39 min.
Main time 3 0:04:00 min Main time 3 analogue main time 2
Maximum time 0:00 min The maximal time is the limit of the main time. It is adjustable in minute steps
to a max. of 99 min. or 1 hr 39 minutes.
The maximum time is the admissible tanning time, given by the producer of
the sun beds. If the maximal time is follow-up, burnings threats!
If “0” minutes are set up, this function is deactivated and the main time can
be bought by choice! If you pay with chip card, the maximum time you can
payislimitedbytheskintypeorbythersttanning,whichisdepositonthe
chip card.
The maximum time is adjusted on the absolutely highest minute time amount
of all skin types (limit switching). It should be adjusted the minute value at
most, which conforms of a dose of 800 J/m² (this is to infer from the manual
of the tanning bed).
Run-out time 3:00 min The run-out time is the additional time of the ventilator of a sun bed, after
the main time has run out. Therefore, run-out time relay, depending on how
long the run-out time is set, remains on longer than the main time. It can be
adjusted in 5 steps to max. of 9:55 minutes.
Price Thepriceoersthepossibilitytoprogramtheamount,payableforeachmain
time. It is adjustable from 0,1 (EUR/SFr/…..) up to 99,9 (EUR/SFr/….) in
0,1,10 or 100 steps depending on the digits after comma. The full price must
be paid to buy each main time.
Price step card 1.0 EUR Thepricestepcardoersthepossibilitytousethefollowingdescribedfunc-
tions,byactivatedminimumpayment.BytherstpressofthePLUS key, the
full card price is accounted and therefore the full main time sold. With every
further pressing, the set value under the price step card, will be deducted and
the correspondingly proportional time will be sold.
Revalue step card 1.0 EUR Therevaluestepcardoersthepossibilitytosettheamountfortherevalue
step, which in revalue mode with each pressing of the PLUS key, the card
is credited or with each pressing of the RESET key, the card is debited. The
revalue is opened by inserting the type 73 card. With the revalue step card
adjusted to 0.0 EUR, the revalue mode is deactivated and by inserting the
type73card,anerrorcodeE35isdisplayed.Therevaluestepcardoersthe
possibility, to set the revalue step size. Should a credit card be revaluated,
the revalue menu must be opened by inserting the type card 73. After a cre-
dit card has been inserted, each pressing of the PLUS key, credits the set
amount from the credit card. Debiting with the RESET key can only be made
according to the existing amount before debiting.
Service interval 1 0 hrs Theserviceinterval1oersthepossibilitytonoteoperatinghours.Whenthe
service hours counter 1 reaches the operating hours, an exclamation mark
will be shown on the display and signals the need of service. By cancelling
the hour counter 1 the exclamation mark is also deleted. The service interval
is adjustable in hour steps up to 999 hours. If “0” hours are set, the function
is disabled.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 16 -
Display information Factory setting Description
Service interval 2 0 hrs The service interval 2 oers the possibility for further noticing operating
hours. When the service hours counter 2 reaches the operating hours, an
exclamation mark will be shown on the display and signals the need of ser-
vice. By cancelling the hour counter 2 the exclamation mark is also deleted.
The service interval is adjustable in hour steps up to 999 hours. If “0” hours
are set, the function is disabled.
Service interval 3 0 hrs Theserviceinterval3oersthepossibilitytonoteoperatinghours.Whenthe
service hours counter 3 reaches the operating hours, an exclamation mark
will be shown on the display and signals the need of service. By cancelling
the hour counter 3 the exclamation mark is also deleted. The service interval
is adjustable in hour steps up to 999 hours. If “0” hours are set, the function
is disabled.
Hours
Minutes
no Indicatingthehours/minutesoersthepossibilitytoshowthemaintimein
minutes and seconds or in hours, minutes and seconds.
●If “Yes” is set, then the display will show the time in hours and mi-
nutes.
●If “No” is set, then the display will show the time in minutes.
HQL time yes TheHQLTimeoersthepossibilitytohinderthenewstartofamaintime,
during the run-out time. The newly bought main time will be accounted with
the amount of remaining run-out time of the payment. If this function is not
activated then the run-out time is immaterial, the main time will start as soon
as the pre-run time has ended. Should the compulsory remote start be ac-
tivated (compulsory remote start active, when the pre-run time = 0), the de-
vice can be started with the remote start button after the run-out time has
expired.
●If “yes” is set, is the HQL time activated.
●If “no” is set, is the HQL time deactivated.
Purchase lock by OR no The purchase lock by run-out oers the possibility to block the buying of
main time during the run-out time. By activating this option the coin insert
and chip card are blocked during the run-out time. Buying time during run-
out time is impossible.
●If “yes” is set, the purchase lock by run-out is activated.
●If “no” is set, the purchase lock by run-out is deactivated.
Pre-run relay no Thepre-runrelayoersthepossibilitytoswitchthefanonatthebeginning
of the pre-run time. They remain switched on until run-out time is ended.
When the pre-run time is set to 0, the fan will start by activating the remote
start and stays on until the end of the run-out time.
●If “yes” is set, the pre-run relay is activated.
●If “no” is set, the pre-run relay is deactivated

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 17 -
11.2.2 Clock menu
to call with: to quit with:
Is a chip card type 63 non-existing, you can start the menu also
with change over the DIP switches no. 3 and 4 on "ON".
Iftheprogrammingisnished,youmustchangeonlyDIPswitch
no. 4 on "OFF".
The following menu options are successively programmable:
Insert chip card
type 63
Pull out chip card
type 63
Display information Factory setting Description
Current time S 17:24:41 Thecurrenttimeoersthepossibilitytosetthecurrenttimeanddate.
●By pressing the RESET button the hours will be increased.
●By pressing the PLUS button the minutes will be increased.
Current day and
month
27.01 Thecurrent dayandmonth oersthe possibility to set thecurrent day and
month.
●By pressing the RESET button the days will be increased.
●By pressing PLUS button the months will be increased.
Current year 2012 Thecurrentyearoersthepossibilitytosetthecurrentyear(between1990
- 2089).
●By pressing the RESET button the years will be increased in decades.
●By pressing the PLUS button the years will be increased year after
year.
Current week day Fr Thecurrentweekdayoersthepossibilitytosetthecurrentday.
●By pressing the PLUS button the week days will be scrolled.
Autom.
Summertime ^
yes Automatic summer time switching is to be set up on “yes” or “no”.
yes: in the last Sunday of March the time is set automatic on summer time, in
last Sunday of October it will be automatic set on wintertime. The changing
timings will be calculated and do not have to be set. At the beginning of the
summer time the clock will be set up with 1 hour forward (at night from 2:00
to 3:00), at the end of the season the clock will be set up 1 hour backward
(at night from 3:00 to 2:00).
These timings are in agreement with the European Union summer time
procedure. They have been implemented by other states (stand 2004.
Further information: www.ptb.de, search domain “summer time”).
no: no automatic summer time setting
The switching times
Theswitchingtimeisonlyavailableandprogrammable,ifinthecongurationmenu,bythepaymenttypes,aHappy
Hourpaymenttypehasbeenactivated!Forfurtherpaymenttypesareneededadditionalinstructions.Tosetswitching
times,onemustrstentertheswitchingtimefromthetarishouldbeactivatedandthenthetariwhichwillbeactiva-
ted.
Example:switchtime2shouldbeactivatedfromMondaytoFridayfrom10:00–14:00,afterthattari1shouldbeactivated.
Theswitchtimeisset:Monday–Friday1:10:00andthentari1:2.ThenentertimeswitchMonday–Friday2:14:00nowenter
aftertari2:1.
By switching times, the hours will be increased by pressing the RESET button. The minutes will be changed by pressing PLUS
button.Apaymentisnotpossibleduringactivatedblockage.ThetariswillbechosenbythePLUS button.
The grey deposited menu option must be only activated
inthecongurationmenu,underpaymenttypewithHap-
pyHour payment type, otherwise it does not appear by
programming.
^ Countries, which do not have summer time switching, must de-
activate this menu point with “NO”.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 18 -
Display information Factory setting Description
Switch time Mo-Fr 1 **:** First switching time (valid from Monday to Friday)
TariMo-Fr1 *Firsttari(validfromMondaytoFriday).
Thetariisfreelychosenbetweentari1,2,3andblockage.(Apaymentis
not possible during the activated blockage).
Switch time Mo-Fr 2 **:** Second switching time (valid from Monday to Friday)
TariMo-Fr2 *Second tari (valid from Monday to Friday). The tari is freely chosen bet-
weentari1,2,3anblockage.(Apaymentisnotpossibleduringtheactivated
blockage).
Switch time Mo-Fr 3 **:** Third switching time (valid from Monday to Friday).
TariMo-Fr3 *Thirdtari(validfromMondaytoFriday).Thetariisfreelychosenbetween
tari 1, 2, 3 and blockage. (A payment is not possible during the activated
blockage).
Switch time Mo-Fr 4 **:** Fourth switching time (valid from Monday to Friday).
TariMo-Fr4 *Fourthtari(validfromMondaytoFriday).Thetariisfreelychosenbetween
tari 1, 2, 3 and blockage. (A payment is not possible during the activated
blockage).
Switch time Sa 1 **:** First switching time (valid only for Saturday).
TariSa1 *Firsttari(validonlyforSaturday).Thetariisfreelychosenbetweentari1,
2, 3 and blockage. (A payment is not possible during the activated blockage).
…etc.AlsoforSaturdaysthereare4timeswitchesand4tarisprogrammable.
Switch time So 1 **:** First switching time (valid only for Sunday).
TariSo1 *Firsttari(validonlyforSunday).Thetariisfreelychosenbetween1,2,3
and blockage. (A payment is not possible during activated blockage).…etc.
AlsoforSundaysthereare4timeswitchesand4tarisprogrammable.
11.2.3 Congurationmenu
to call with: to quit with:
Is a chip card type 83 non-existing, you can start the menu also
with change over the DIP switches no. 1, 2 and 3 on "on".
Iftheprogrammingisnished,youmustchangeonlyDIPswitch
no.1and2on"o".
Insert
chip card
type 83
Pull out
chip card
type 83
Bytrespassingthecongurationmenudonotchan-
ge any values! Uncontrolled programming can´t be
followed by your wished functions. In the worst case
the device can be put out of function totally.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 19 -
Display information Factory setting Description
Language* German The language oers the possibility to set the typical country language. The
language selection depends on the software and it is may be chosen between
version A, B, C. It must be denoted by order.
Following can be chosen:
Version A: German, French, Italian, Flemish
Version B: English, Norwegian, Danish, Swedish
Version C: Polish, Spanish, Croatian
Currency EUR Thecurrencyadjustmentoersthepossibility,underthecurrencyabbreviation
EUR; neutral (no abbreviation) PLN; SKr; Kn; GBP; Dkr or Kr. The currency
abbreviation appears on the display.
Payment type normal By payment “normal” you have the possibility to enter one price and one time.
Int. door opener no The internal door opener oers the possibility by inserting a chip card or by
pressing the RESET button, to receive 30 seconds free main time, e.g. to open
an electronic washing machine door, after the regular main time has expired.
After each function this function is disabled for one minute.
●If “yes” is set, the function is activated.
●If “no” is set, the function is deactivated.
Daily counters yes The settings of Daily counters allows you to show or hide all daily counters in the
statistics menu.
●If "yes" is set, all available daily counters are displayed.
●If set to "no", no daily counters will be displayed.
3 digits main time no The3digitsmaintimeoersthepossibilitytoshowthemaintimein2or3digits
on the display.
●If “no” is set, main time will be displayed in 2 digits and so limited to 99
min. or 1 hour 39 min.
●If “yes” is set, the main time will displayed in 3 digits
Memory lock no Thememorylockoersthepossibilitytoobviatetherepeatedsaleofmaintime.
●If “yes” is set the main time can be bought only once.
●If “no” is set, can the main time repeatable sold.
Main failure fuse no Themainsfailure fuseoers the possibilitythat the maintime remainseven
after a mains failure. After the mains supply is restored again, the devices with
the stored main time will be switched back on, per random time generator, to
prevent a mains overload.
●If “yes” is set, the same main times and prices apply irrespective if pay-
ment is made cash or by card.
● If“no”isset,dieringmaintimesandpriceswillsetforpaymentcash
or by card.
Following menu options are successively programmable:
* The language selection is dependent from the respective software
version.

Holtkamp Electronics VENUS 6600XL techn. Stand 04.2016 4074_04.2016 V09.2019
- 20 -
11.2.4 Buscongurationmenu
This menu is only of interest to you, if you owe a network (HELIO-
TEX or DELTA XL) or you need a connection to SkinControl. If
you want to set up a network, please read the instructions, which
are included with the particular software.
to call with:
Therefore DIP switch 3 must be set to "ON"
to quit with:
OK hold OK
button +
insert chip card
tape 53
unhand OK
button +pull out chip
card
type 53
OK
Following menu options are successively programmable:
Display information Factory setting Description
Device address 1 With the device address, you have the possibility, to allocate to the VENUS
an address between 1–37 in a bus system. Be careful that two devices do not
receive the same address.
EveryXLdevicemusthaveadierentdeviceno.Theremaynotbedistri-
buted double because the bus system can´t read the particular address.
Besides, the no of the SkinControl device must correspond with the no.
of the particular tanning beds.
Card-Verify no This setting must generally be on "no".
Testing no With the setting testing, you have the possibility, with the setting "no", not to
show several error codes. The standard setting is "no".
Baudrate 9600 With the setting baudrate, you have the possibility to set various data transfer
speed. The smaller the number the slower the data transfer. You have the
possibility to choose between 1200, 2400, 4800, 9600, 19200, and 38400.
The standard setting is 9600 baud.
Parität even With the setting parity, you have the possibility, to check the sent data for mis-
takes. By the setting “even”, the even number bits will be checked, with the
setting “uneven”, the “uneven” numbers. No checking will be carried out, with
the setting "none". The standard setting is "even".
Table of contents
Other Holtkamp Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Maple Systems
Maple Systems AEx-100 Series Operation manual

Partner
Partner SP-1060 IoT Ready quick start guide

Bilanciai
Bilanciai DD2060 X Series Use and maintenance manual

HP
HP RP7 Model 7800 Hardware reference guide

Janus Remote Communications
Janus Remote Communications POTSwap HSPA910PS Product user manual

Ericsson
Ericsson W25 datasheet