BG-12LX
Addressable Manual Pull Station
Addressable Devices
DF-52013:D • E-100
FLPullStation.jpg
General
The Fire·Lite BG-12LX is a state-of-the-art, dual-action (i.e.,
requires two motions to activate the station) pull station that
includes an addressable interface (mounted inside) for
Fire·Lite’s addressable fire alarm control panels (FACPs)
Because the BG-12LX is addressable, the control panel can
display the exact location of the activated manual station. This
leads fire personnel quickly to the location of the alarm.
Features
• Maintenance personnel can open station for inspection and
address setting without causing an alarm condition.
• Built-in bicolor LED, which is visible through the handle of
the station, flashes in normal operation and latches steady
red when in alarm.
• Handle latches in down position and the word “ACTIVATED”
appears to clearly indicate the station has been operated.
• Captive screw terminals wire-ready for easy connection to
SLC loop (accepts up to 12 AWG/3.25 mm² wire).
• Can be surface mounted (with SB-10 or SB-I/O) or semi-
flush mounted. Semi-flush mount to a standard single-
gang, double-gang, or 4" (10.16 cm) square electrical box.
• Smooth dual-action design.
• Meets ADAAG controls and operating mechanisms guide-
lines (Section 4.1.3[13]); meets ADA requirement for 5 lb.
maximum activation force.
• Highly visible.
• Attractive shape and textured finish.
• Key reset.
• Includes Braille text on station handle.
• Optional trim ring (BG12TR).
• Meets UL 38, Standard for Manually Actuated Signaling
Boxes.
Construction
Shell, door, and handle are molded of durable polycarbonate
material with a textured finish.
Specifications
•Shipping Weight: 9.6 oz. (272.15 g)
•Normal operating voltage: 24 VDC.
•Maximum SLC loop voltage: 28.0 VDC.
•Maximum SLC standby current: 375 μA.
•Maximum SLC alarm current: 5 mA.
•Temperature Range: 32°F to 120°F (0°C to 49°C)
•Relative Humidity: 10% to 93% (noncondensing)
•For use indoors in a dry location
Installation
The BG-12LX will mount semi-flush into a single-gang, double-
gang, or standard 4" (10.16 cm) square electrical outlet box, or
will surface mount to the model SB-10 or SB-I/O surface back-
box. If the BG-12LX is being semi-flush mounted, then the
optional trim ring (BG12TR) may be used. The BG12TR is
usually needed for semi-flush mounting with 4" (10.16 cm) or
double-gang boxes (not with single-gang boxes).
Operation
Pushing in, then pulling down on the handle causes it to latch
in the down/activated position. Once latched, the word “ACTI-
VATED” (in bright yellow) appears at the top of the handle,
while a portion of the handle protrudes from the bottom of the
station. To reset the station, simply unlock the station with the
key and pull the door open. This action resets the handle; clos-
ing the door automatically resets the switch.
Each manual station, on command from the control panel,
sends data to the panel representing the state of the manual
switch. Two rotary decimal switches allow address settings
(1 – 159 with Breakaway Tab removed for MS-9600 Series, 1 –
99 and MS-9200UDLS, 1 – 50 for MS-9050UD).
Architectural/Engineering
Specifications
Manual Fire Alarm Stations shall be non-coded, with a key-
operated reset lock in order that they may be tested, and so
designed that after actual Emergency Operation, they cannot
be restored to normal except by use of a key. An operated sta-
tion shall automatically condition itself so as to be visually
detected as activated. Manual stations shall be constructed of
red-colored polycarbonate material with clearly visible operat-
ing instructions provided on the cover. The word FIRE shall
appear on the front of the stations in white letters, 1.00 inches
(2.54 cm) or larger. Stations shall be suitable for surface
mounting on matching backbox SB-10 or SB-I/O; or semi-flush
mounting on a standard single-gang, double-gang, or
4" (10.16 cm) square electrical box, and shall be installed
Page 2 of 2 — DF-52013:D • 4/13/2012
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.
www.firelite.com
FireLite® Alarms® is a registered trademark of Honeywell International Inc.
©2012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
Made in the U.S. A.
within the limits defined by the Americans with Disabilities Act
(ADA) or per national/local requirements. Manual Stations
shall be Underwriters Laboratories listed.
Manual stations shall connect with two wires to one of the con-
trol panel SLC loops. The manual station shall, on command
from the control panel, send data to the panel representing the
state of the manual switch. Manual stations shall provide
address setting by use of rotary decimal switches.
Product Line Information
BG-12LX: Dual-action addressable pull station. Includes key
locking feature. (Listed for Canadian and non-Canadian appli-
cations.)
SB-10: Surface backbox; metal.
SB-I/O: Surface backbox; plastic.
BG12TR: Optional trim ring.
17003: Keys, set of two.
Agency Listings and Approvals
In some cases, certain modules or applications may not be
listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
•UL/ULC Listed: S711 (listed for Canadian and non-Cana-
dian applications).
•MEA: 67-02-E.
•CSFM:7150-0075:0184.
• FM Approved.
Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772;
6,632,108.

Other Honeywell Fire Alarm manuals

Honeywell NOTIFIER ID61 User manual

Honeywell

Honeywell NOTIFIER ID61 User manual

Honeywell SILENT KNIGHT RPS-2000 User manual

Honeywell

Honeywell SILENT KNIGHT RPS-2000 User manual

Honeywell Fire-Lite Alarms LCD-80F User manual

Honeywell

Honeywell Fire-Lite Alarms LCD-80F User manual

Honeywell ESSER 804950 User manual

Honeywell

Honeywell ESSER 804950 User manual

Honeywell Gamewell FCI S3 Series User manual

Honeywell

Honeywell Gamewell FCI S3 Series User manual

Honeywell SILENT KNIGHT 5860 Technical manual

Honeywell

Honeywell SILENT KNIGHT 5860 Technical manual

Honeywell NFS Supra User manual

Honeywell

Honeywell NFS Supra User manual

Honeywell 800-04433V1 Assembly instructions

Honeywell

Honeywell 800-04433V1 Assembly instructions

Honeywell NOTIFIER IFS-2600 Technical document

Honeywell

Honeywell NOTIFIER IFS-2600 Technical document

Honeywell Notifier AM12-24 User manual

Honeywell

Honeywell Notifier AM12-24 User manual

Honeywell ESSER 761694 Service manual

Honeywell

Honeywell ESSER 761694 Service manual

Honeywell STX Operating instructions

Honeywell

Honeywell STX Operating instructions

Honeywell SMX-AUS User manual

Honeywell

Honeywell SMX-AUS User manual

Honeywell Farenhyt Series User manual

Honeywell

Honeywell Farenhyt Series User manual

Honeywell NOTIFIER AM-8000 Owner's manual

Honeywell

Honeywell NOTIFIER AM-8000 Owner's manual

Honeywell Gent Vigilon User manual

Honeywell

Honeywell Gent Vigilon User manual

Honeywell C7015A User manual

Honeywell

Honeywell C7015A User manual

Honeywell SILENT KNIGHT SK-5208 User manual

Honeywell

Honeywell SILENT KNIGHT SK-5208 User manual

Honeywell Notifier NFS-320SYS User manual

Honeywell

Honeywell Notifier NFS-320SYS User manual

Honeywell NOTIFIER IDR-M Guide

Honeywell

Honeywell NOTIFIER IDR-M Guide

Honeywell NOTIFIER NFS-320C User manual

Honeywell

Honeywell NOTIFIER NFS-320C User manual

Honeywell TC844A1015 User manual

Honeywell

Honeywell TC844A1015 User manual

Honeywell HW-TG7FS-V Installation guide

Honeywell

Honeywell HW-TG7FS-V Installation guide

Honeywell Silent Knight IntelliKnight 5820XL User manual

Honeywell

Honeywell Silent Knight IntelliKnight 5820XL User manual

Popular Fire Alarm manuals by other brands

Faraday 15220A owner's manual

Faraday

Faraday 15220A owner's manual

Cooper Notification E60H-24MCCH installation instructions

Cooper Notification

Cooper Notification E60H-24MCCH installation instructions

Brooks FireTracker FT2GAS Operation and technical manual

Brooks

Brooks FireTracker FT2GAS Operation and technical manual

Autronica Autroprime Operator's handbook

Autronica

Autronica Autroprime Operator's handbook

Siemens FDCW221 Technical manual

Siemens

Siemens FDCW221 Technical manual

Simplex 2004 Series Operation guide

Simplex

Simplex 2004 Series Operation guide

Ampac MAN 3038 Product guide

Ampac

Ampac MAN 3038 Product guide

Zeta QT/1 User manual, maintenance guide & log book

Zeta

Zeta QT/1 User manual, maintenance guide & log book

Kidde Fire Systems Argonite Design, installation & maintenance instruction

Kidde Fire Systems

Kidde Fire Systems Argonite Design, installation & maintenance instruction

FireClass Prescient III Application, Installation & Commissioning

FireClass

FireClass Prescient III Application, Installation & Commissioning

Zeta Premier MX-16 User's operation manual

Zeta

Zeta Premier MX-16 User's operation manual

Wheelock RSS-24MCW installation instructions

Wheelock

Wheelock RSS-24MCW installation instructions

Ampac 4210-0050 installation guide

Ampac

Ampac 4210-0050 installation guide

Simplex 4099-9032 installation instructions

Simplex

Simplex 4099-9032 installation instructions

White Rodgers 3098-134 installation instructions

White Rodgers

White Rodgers 3098-134 installation instructions

Zeta MKII-HR installation guide

Zeta

Zeta MKII-HR installation guide

Brooks FIRETRACKER FT128 Quick operation guide

Brooks

Brooks FIRETRACKER FT128 Quick operation guide

olympia electronics BS-536/MAR quick start guide

olympia electronics

olympia electronics BS-536/MAR quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.