The RF link between the Room Thermostat (DT92E) and the Timer
(ST9120C) in Honeywell system packs is pre-configured at the factory
and therefore both units should be installed at the same site.
• Ifproductsfromindividualsystempacksareseparated,ormixed
with other pre-configured system packs during installation, or a
faulty unit is being replaced, the desired units must be specially
configured to allow them to communicate with each other. This
process is called Binding. Please refer to section 5 Binding /
Rebinding Procedure.
• DT92E or ST9120C will not communicate with other RF products
that use different frequencies or communications protocols.
• TheDT92Eroomthermostatrequiresno powersourceotherthan
the batteries provided.
• The ST9120C Timer requires a permanent 230V~ supply.
• TheTimershouldbeinstalledandpoweredupbeforecommencing
the Room Thermostat installation.
Section Page
1 INSTALLING THE ST9120C TIMER ........................... 3
1.1 Mounting ST9120C .................................................................. 3
1.2 Mounting options ..................................................................... 3
1.3 Wiring ST9120C....................................................................... 3
1.4 Final Assembly......................................................................... 3
1.5 ST9120C Internal Wiring.......................................................... 4
1.6 Wiring Diagrams ...................................................................... 4
1.7 Replacement Wiring ................................................................ 5
1.8 Replacing Other Manufacturers’ Time Controls ...................... 5
1.9 Powering Up ST9120C ............................................................ 5
2 INSTALLING THE DT92E ROOM THERMOSTAT ...... 6
2.1 Locating DT92E ....................................................................... 6
2.2 Powering Up DT92E ................................................................ 6
2.3 Signal Strength Test................................................................. 6
2.4 Mounting DT92E ...................................................................... 7
3 SYSTEM CONFIGURATION: ST9120C ..................... 8
3.1 ST9120C Installer Modes......................................................... 8
3.2 Boiler Service Reminder / Shut-down Feature......................... 8
3.3 Installer Setup.......................................................................... 9
3.4 Installer Setup Flowchart ....................................................... 10
3.5 Set Service............................................................................. 10
3.6 Change PIN ........................................................................... 12
3.7 What the User Will See When a Service is Due..................... 12
3.8 Resetting the Service Timer Function.................................... 12
4 SYSTEM CONFIGURATION: DT92E ....................... 13
4.1 DT92E Installer Mode ............................................................ 13
5 BINDING / RE-BINDING PROCEDURE ................... 14
5.1 Binding................................................................................... 14
5.2 ST9120C Guided Binding Menu............................................ 14
5.3 Binding Menu Display............................................................ 14
5.4 How to Bind DT92E to ST9120C............................................ 15
6 COMMISSIONING THE SYSTEM............................. 16
6.1 Completion Checklist for Installation ..................................... 16
Within a typical house the two products should communicate reliably
within a 30m range. It is important to take into consideration that walls and
ceilings will reduce the RF signal. The strength of the RF signal reaching
the Timer depends on the number of walls and ceilings separating it from
the room thermostat, as well as the building construction - the diagram
below illustrates an example of typical signal strength reduction. Walls
and ceilings reinforced with steel or plasterboard walls lined with metal
foil reduce the RF signal significantly more.
RF Signal Propagation
Installation Notes Installation Sequence: Step by Step
Typical example of Building Fabric Signal losses
= Signal Strength
Wall Wall Wall
Ceiling
Max. Signal Length 30 metres