manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security Sensor
  8. •
  9. Honeywell Activ8 PIR User manual

Honeywell Activ8 PIR User manual

PRODUCT DESCRIPTION
The Activ8 PIR detect
or uses a special
designed optical Lens with unique Quad
(Four element) PIR Sensor and new ASIC
based electronics optimized
to eliminate false
alarms, caused by small animals and Pets.
8IR103
PIR MOTION DETECTOR
With PET IMMUNITY up to 25Kg
INSTALLATION INSTRUCTIONS
English
P/N 7101507 REV. B A.Y.
The Activ8 PIR provides unprecedented
levels of immunity ag
ainst visible light.
The Detector offers an exceptional level of
detection capability and stability for every
security installation.
The Activ8 PIR is supplied with Wide Angle
lens.
The Activ8 PIR provides Pet immunity up
to 25Kg (55 lbs). For better immunity
avoid installation in areas where pets can
reach upwards.
Activ8 PIR FEATURES
DETECTION PATTERN
TYPICAL INSTALLATION
SELECT MOUNTING LOCATION
FEATURES
Choose a location most likely to intercept an
intruder. See detection pattern. The Quad high
quality sensor detects
motion crossing the beam;
it is less sensitive det
ecting motion towards the
detector.
Quad Linear Imaging Technology for
sharp analysis of body dimensions and
differentiation from background and
animals.
New ASIC based electronics.
The Activ8 PIR performs best when provided
with a constant and stable environment.
Immunity to animals up to 25kg (55 lbs).
18m Detection Range with Wide Angle
Lens.
AVOID THE FOLLOWING LOCATIONS
Temperature compensation.
Facing direct sunlight.
Compact Design for Residential
Installation.
Facing areas subject to rapid
temperature changes.
Variable pulse width adjustment.
Areas with air ducts
or substantial air
flows.
Sensitivity adjustment.
Environmental immunity.
Height installation calibration
free (1.8m – 2.4m).
LED Remote function.
REMOVAL OF FRONT COVER
MOUNTING THE DETECTOR
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
KNOCKOUT HOLES
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the des
ired holes for proper
installation.
4. The circular and rectangul
ar indentations at the
bottom base are the kno
ckout holes for wire
entry. You may also us
e mounting holes that
are not in use for running the wiring into the
detector.(For option with bracket - lead wire
through the bracket)
5. Mount the detec
tor base to the wall, corner or
ceiling. (For option with
bracket install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire
to terminal block.
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
A. Wire access
holes
A
ADB. Use for flat
wall
mounting
A
B
CC
BC. Corner
mounting -
use all 4
holes. Sharp
left or right
angle
mounting -
use 2 holes
(top and
bottom)
C C
B
B
D. For bracket
mounting
Unscrew the holding
screw and open base
DETECTOR INSTALLATION
PCB LAYOUT
TERMINAL BLOCK CONNECTIONS
Terminals 4 & 5 - Marked
RELAY
These are the output re
lay contacts of the
detector. Connect to a
normally closed zone in
the control panel.
Terminal 7 - Marked + (+12V)
Terminals 1 & 6 - Marked EOL
End of line
option.
Connect to a positive Vo
ltage output of 8.2 -
16Vdc source (usually
from the alarm control
unit)
Terminals 2 & 3 - Marked TAMPER
If a Tamper function is
required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
Terminal 8 - Marked - (GND)
Connect to the negative
Voltage output or ground
of the control panel.
SETTING-UP THE DETECTOR
LED ENABLE JUMPER SETTING
PULSE WIDTH JUMPER SETTING
PIR SENSITIVITY ADJUSTMENT
PET IMMUNITY JUMPER SETTING
POTENTIOMETER
adjustment according to
protected area range.
Use the potentiometer to
adjust the detection
range between 68% and 100% (factory set to
84%). Rotate the potentiometer clockwise to
increase range, counter-c
lockwise to decrease
range.
WIRE SIZE REQUIREMENTS
Use #22 AWG (0.5 mm) or wires with a larger
diameter. Use the following table to determine
required wire gauge (diameter) and length of
wire between the detecto
r and the control panel.
Wire Length m 200 300 400 800
Wire Diameter mm .5 .75 1.0 1.5
Wire Length ft. 800 1200 2000 3400
Wire Gauge # 22 20 18 16
Very stable environment
LED ON
Jumper #1 = ON
Without PET
Moderate nuisance situation
LED OFF
Jumper #2 = ON
PET up to 15 kg (33.1 lb)
Immunity to an
animal up to 15 kg
Relatively high chance of false
alarms
Jumper #3 = ON
Immunity to an
animal up to 25 kg
PET up to 25 kg (55 lb)
TESTING
BRACKET INSTALLATION OPTION
TEST PROCEDURES
WAIT FOR ONE MINUTE OF WARM UP TIME
AFTER APPLYING 12 VDC POWER.
CONDUCT TESTING WITH THE PROTECTED
AREA CLEARED OF ALL PEOPLE.
Walk test
1. Remove front cover.
The pulse jumper must be in position 1. The
LED must be enabled.
2. Replace the front cover.
3. Start walking slowly
across the detection zone.
4. Observe that the detector
s LED lights
whenever motion is detected.
5. Allow 5 sec. between eac
h test for the detector
to stabilize.
6. After the walk test is
completed, the LED may
be disabled.
NOTE:
Walk tests should be conduc
ted, at least once a
year, to confirm proper operation and coverage of
the detector.
WALL AND CEILING INSTALLATION OPTIONS
REPLACING THE LENS
1. Remove the front cover.
2. Using a small flat screwdriver, press on left
and right snaps of the
lens and pull the lens
out from its place (front cover side).
3. Replace a new lens.
4. Push the lens to its place by pressing again
from outside of the front
cover until a click is
heard.
5. Replace front cover.
TECHNICAL SPECIFICATION
MODEL Activ8 PIR
Detection Method Quad (Four element) PIR
Power Input 7.8 to 16 VDC
Current Draw Standby: 8mA (±
5%)
Active: 10mA (±
5%)
Temperature
Honeywell Security & Communications
(UK64)Newhouse Industrial Estate
Compensation YES
Pulse Width Adjustable
Motherwell
Alarm Period 2 sec (±
0.5sec)
Lanarkshire
Alarm Output N.C
28VDC 0.1 A with 27Ohm series protection resistor
ML1 5SB
Tamper Switch
N.C 28VDC 0.1A with
Tel +44 (0)1698 738200
10 Ohm series protection resistor - open when cover is
removed
Fax +44 (0)1698 738300
Warm Up Period 60sec (±
5sec)
Tech Support: +44 (0)844 8000 235
LED Indicator LED is ON during alarm
Operating Temperature -20
C to +60
C
(-4
F to +140
F)
RFI Protection 30V/m 10 - 1000MHz
EMI Protection 50,000V
of electrical interference fr
om lightning or power through
Dimensions 90mm x 59mm x 37mm
(3.54
x 2.32
x 1.46
)
Weight
40gr (1.4oz)
truder
in
/
uk
/
security
/
com
.
honeywell
.
www
.

This manual suits for next models

1

Other Honeywell Security Sensor manuals

Honeywell Connected Home DO8EZS User manual

Honeywell

Honeywell Connected Home DO8EZS User manual

Honeywell 5800PIR-OD Instruction Manual

Honeywell

Honeywell 5800PIR-OD Instruction Manual

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell FIRE-LITE ALARMS SD365CO User manual

Honeywell

Honeywell FIRE-LITE ALARMS SD365CO User manual

Honeywell 2MLF-RD4A User manual

Honeywell

Honeywell 2MLF-RD4A User manual

Honeywell Eclipse Instruction Manual

Honeywell

Honeywell Eclipse Instruction Manual

Honeywell Miller QuickPick Rescue Kits Operator's manual

Honeywell

Honeywell Miller QuickPick Rescue Kits Operator's manual

Honeywell GasAlert Max XT II User manual

Honeywell

Honeywell GasAlert Max XT II User manual

Honeywell BW Ultra User manual

Honeywell

Honeywell BW Ultra User manual

Honeywell Lyric User manual

Honeywell

Honeywell Lyric User manual

Honeywell Activ8 DT User manual

Honeywell

Honeywell Activ8 DT User manual

Honeywell C7961E Operation manual

Honeywell

Honeywell C7961E Operation manual

Honeywell FlexGuard FG-1625TAS User manual

Honeywell

Honeywell FlexGuard FG-1625TAS User manual

Honeywell 5800COMBO User manual

Honeywell

Honeywell 5800COMBO User manual

Honeywell RCA902N User manual

Honeywell

Honeywell RCA902N User manual

Honeywell MultiPro User manual

Honeywell

Honeywell MultiPro User manual

Honeywell Viewguard DUAL AM FAI User manual

Honeywell

Honeywell Viewguard DUAL AM FAI User manual

Honeywell SPM Flex User manual

Honeywell

Honeywell SPM Flex User manual

Honeywell IQ Force Installation manual

Honeywell

Honeywell IQ Force Installation manual

Honeywell 2110B30 0 Series User manual

Honeywell

Honeywell 2110B30 0 Series User manual

Honeywell HAQSPA-R User manual

Honeywell

Honeywell HAQSPA-R User manual

Honeywell SIXCO User manual

Honeywell

Honeywell SIXCO User manual

Honeywell BW Solo User manual

Honeywell

Honeywell BW Solo User manual

Honeywell Ex-Or MLS2401CDR Installation and operation manual

Honeywell

Honeywell Ex-Or MLS2401CDR Installation and operation manual

Popular Security Sensor manuals by other brands

Planet LS100 Series user manual

Planet

Planet LS100 Series user manual

C.P. Electronics EBDSPIR-DD-LV installation guide

C.P. Electronics

C.P. Electronics EBDSPIR-DD-LV installation guide

HIK VISION DS-PD2-P15C-W manual

HIK VISION

HIK VISION DS-PD2-P15C-W manual

HIK VISION DS-PDTT15AM-LM-WB user manual

HIK VISION

HIK VISION DS-PDTT15AM-LM-WB user manual

seeed studio RG-9 quick start guide

seeed studio

seeed studio RG-9 quick start guide

Paradox NV75MR installation manual

Paradox

Paradox NV75MR installation manual

Cooper & Hunter SPHNS-S01E user manual

Cooper & Hunter

Cooper & Hunter SPHNS-S01E user manual

M-TI FREEDOM MICRO II product manual

M-TI

M-TI FREEDOM MICRO II product manual

Paradox EB-N94 installation guide

Paradox

Paradox EB-N94 installation guide

C.P. Electronics MWS6-DD-LV installation guide

C.P. Electronics

C.P. Electronics MWS6-DD-LV installation guide

Ceasefire PRO-SENSE TI-002271 quick start guide

Ceasefire

Ceasefire PRO-SENSE TI-002271 quick start guide

Paradox SR250 quick start guide

Paradox

Paradox SR250 quick start guide

Tinker & Rasor 7-T Product instructions

Tinker & Rasor

Tinker & Rasor 7-T Product instructions

Sferalabs Exo Sense RP user guide

Sferalabs

Sferalabs Exo Sense RP user guide

HIK VISION DS-PD2-D10P-W1 user manual

HIK VISION

HIK VISION DS-PD2-D10P-W1 user manual

North Light HJ9104 manual

North Light

North Light HJ9104 manual

Timeguard PDFM362 instructions

Timeguard

Timeguard PDFM362 instructions

Paradox PMD85 installation manual

Paradox

Paradox PMD85 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.