Diagnosis DV: If DV does not energize, check for 24VAC at CB K2 #10 (W/BU) to
neutral (LBU). If24VAC is not present, check control switch continuity. If open while in
the "DRAIN" position, replace control switch. If closed, check for 0VDC at CB
K9 #1(W/BK)to K9 #2 (W/BK). If5VDC is present and control switch is closed, replace
CB. If DV energizes (24VAC present at CB K2 #10 (W/BU) to neutral (LBU)), and water
does not drain, check for restricted DV and DV solenoid continuity. Clean or replace as
needed.
Diagnosis BC: Conrm green LED is on. If not and yellow LED is on or ashing, move
ice away from BC sensor. If no ice is present, clean the BC sensor lens with a warm,
clean damp cloth. If cleaning the lens does not work, see "II.D. Bin Control Check."
3) After all of the water has drained, move control switch to the "ICE" position.
CB "POWER OK" LED and BC green LED are on.
4) Fill Cycle – "WTRIN" LED is on. WV energizes. 90-sec. low water safety timer begins.
LFS closes. Nothing occurs at this time. Reservoir continues to ll until UFS closes.
Once UFS closes, 90-sec. low water safety timer terminates and 30-min. freeze timer
starts. WV de-energizes. Diagnosis: Check that "WTRIN" LED turns on and water
lls the reservoir. If not, check for water supply line shut-off valve closed, restricted
water lters, and restricted WV screen. Next, check for 24VAC at CB K2 #8(O) to
neutral(LBU). If 24VAC is not present, replace CB. If 24VAC is present, turn off the
power switch, disconnect the WV wires and check WV solenoid continuity. Ifopen,
replace WV. Reconnect WV wires, move the power switch to the "ON" position, then
check that DV is not leaking by. Conrm that WV shuts off when UFS closes.
Note: Low Water Safety– If UFS remains open 90 sec. after WV energizes, a 1-beep
alarm sounds. This alarm resets automatically once UFS closes.
5) Ice Purge Cycle – "GM" LED is on. 30-sec. GM delay timer starts. WV de-energizes
and "WTRIN" LED turns off. Once the 30-sec. GM delay timer terminates, GM, FM/
FMR, and CDR energize. CDR cannot energize unless GM circuit is complete (fuse,
internal protector, and motor windings). Once CDR energizes, CB K9 #5 (W/O) and
CB K9 #6 (W/O) 5VDC circuit closes and 5-min. ice purge timer starts. See "II.C.3)
c. Compressor Delay Relay (5-min. Ice Purge Timer Circuit)." If CDR de-energizes,
CBK9#5 (W/O) and CB K9 #6 (W/O) circuit opens, an 8-beep alarm occurs. See"III.B.
LED Lights and Alarm Safeties." Note: To bypass ice purge cycle and go straight to
freeze cycle, press CB "SERVICE" button during 30 sec. GM delay time.
Diagnosis CB: Check that UFS closed, WV LED turned off and WVde-energized.
IfUFS is closed, "WV" LED is off, and "GM" LED is off, replace CB. If "GM" LED is
on and GM is off, conrm 115VAC at CB K1 #2 (BR) to neutral(W). If115VAC is not
present, check for loose connection from power switch. If 115VAC is present, check for
115VAC at CB K1 #3 (R) to neutral (W). If115VAC is not present, replace CB.
Diagnosis GM: If115VAC is present at CB K1 #3 (R) to neutral(W), check GM fuse,
GM capacitor, GM windings, and GM coupling between auger and GM.
Diagnosis CDR: Once GM energizes, check for 115VAC at CDR #7 (O) to neutral
(W). If 115VAC is present and CDR contacts #3 (W/O) and #5 (W/O) do not close,
replace CDR. See "II.C.3)c. Compressor Delay Relay (5-min. Ice Purge Timer Circuit)."
Diagnosis FM/FMR: If115VAC is present at CB K1 #3 (R) to neutral(W) and
FM/FMR does not energize, check FM/FMR capacitor, windings, and bearings.