5
•
The opening for the power supply connection is
22.2 mm. diameter to fit a conduit.
•If a powercordisused toprovideelectricityto the icemaker
in place of the permanent (conduit) connection, a gland
should be installed at the 22.2 mm. power
supply
connection. Thisglandshouldbeofthecorrectsizeforthe
power supply cord being installed. The size of the
conductorsofthispowersupplycord shouldbesuitablefor
the electrical consumption of this icemaker.
As the colours of the wires in the terminal box of this
appliance may not correspond with field supplied wiring or
with the markings identifying the terminals in your power
supply receptacle, proceed as follows:
The wire which is coloured Green-and-Yellow must be
connectedtotheterminalinthereceptaclewhichismarked
with the letter E or by the symbol or
coloured Green
or Green-and-Yellow. The wire which is coloured Blue
mustbeconnectedtotheterminalwhichismarkedwiththe
letter “N” or coloured Black. The wire which is coloured
Brown must be connected to the terminal which is marked
with the letter L or coloured Red.
•
Usually an electrical permit and services of a licensed
electrician are required.
• For the electrical connection of the URC-12F-E remote
condenser unit to the fan motor junction of the KM-
1300SRH-E, an IPX4 rated conduit is recommended. If a
powersupplycordisused,thecorditselfshouldbecertified
for outdoor use and a gland rated IPX4 should be used
where the cord enters the model URC-12F-E remote
condenser.
•
Usually an electrical permit and services of a licensed
electrician are required.
7. INSTALLATION OF REMOTE CONDENSER7. INSTALLATION OF REMOTE CONDENSER
7. INSTALLATION OF REMOTE CONDENSER7. INSTALLATION OF REMOTE CONDENSER
7. INSTALLATION OF REMOTE CONDENSER
UNIT (Remote Air-Cooled Model Only)UNIT (Remote Air-Cooled Model Only)
UNIT (Remote Air-Cooled Model Only)UNIT (Remote Air-Cooled Model Only)
UNIT (Remote Air-Cooled Model Only)
[a] UNPACKING[a] UNPACKING
[a] UNPACKING[a] UNPACKING
[a] UNPACKING
1)Unpackandremoveshippingcarton,tape(s)andpacking.
2) Check that the refrigerant lines do not rub or touch lines
or other surfaces, and that the fan blade turns freely.
[b] LOCATION[b] LOCATION
[b] LOCATION[b] LOCATION
[b] LOCATION
The condenser unit is intended for outdoor use and must be
positioned in a permanent, well ventilated site under the
following guidelines:
•
Select a firm and flat site.
• Should not be exposed to harsh or adverse weather
conditions.
Fig. 5Fig. 5
Fig. 5Fig. 5
Fig. 5
6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION6. ELECTRICAL CONNECTION
6. ELECTRICAL CONNECTION
WARNINGWARNING
WARNINGWARNING
WARNING
THIS APPLIANCE MUST BE EARTHEDTHIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHEDTHIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the na-
tional and local electrical code requirements. To
preventpossiblesevereelectricalshocktoindividu-
als or extensive damage to equipment, install a
properearthwiretotheicemaker. Turnoffthepower
supply before any maintenance, repairs or cleaning
is undertaken.
•
This icemaker must have a separate power supply or
receptacle of proper capacity. See the Nameplate. It
isrecommendedthatthisicemakerbetheonlyelectrical
device on its power supply circuit.
• Stacked icemakers should each have a separate
receptacle, but they must all be connected in parallel
tothesamesinglephasesupplyorcircuitwithsufficient
ampacity.
ENGLISH