Thank you for purchasing the HOZAN F-67-L ESD GLO ES, LARGE. With proper care
and handling, these fine instruments will provide years of trouble-free operation. Please
read this entire instruction manual carefully before attempting to place these instruments in
service. Please keep this instruction manual available for reference.
ESD GROVES, LARGE (10pairs/pack)
F-67-L
1. Do not use on energized places. This
could cause a shock.
2. Do not touch liquid or hot things directly
while wearing these gloves.
Warning
Precautions
Carry out inspection periodically to ensure
that they maintain their potential.
Caution
INSTRUCTION MANUAL
16.05
1-2-12 Saiwaicho, Naniwa-ku, Osaka 556-0021, Japan
Tel : +81-6-6567-3111 F a x : +81-6-6562-0024
3
33
3
Specifications
27 g
Gray
Cleats: P C
Other than cleats:
Nylon, Conductive yarn
(Carbon fiber)
Weight
Materials
Color (wrist)
ESD standard
Charge decay from
1000 to 100 in less
than 2 secs.
Size
OAL 225 mm
Regarding grounding
These products
show their
primary function
under being
grounded.
Please use with
wearing F-154
Wrist Strap and
such.
1. Always ground when use, otherwise
these do not function causing damage
to electronic components, shock to
operators or an explosion according to
circumstances.
2. Prepare a grounding line for ESD
separately from the grounding line
concerning power line. This could
cause a shock.
Warning
ground
L
Antistatic standards
Foundation Standard released by the Japan Accreditation Board for Conformity (RCJ).
“Standard Electrostatic rotection Requirements for Electronic Devices” (RCJS
-
5
-
1)
HOZAN’s ESD
-
safe products are controlled with reference to the Japanese standard
(RCJS
-
5
-
* ) which is based on the international standard (IEC6 340
-
5
-
).
Products which bear the “ “ mark are products to which the standard values
(see table below) apply. The “ESD Standard” listed on each of the product pages
denote the HOZAN standard for the product.
Where foot grounder and floor system are employed as personal grounding device, the
grounding resistance must be determined by the ESD coordinator. The recommended
value is 7.5 X 10
5
to 3.5 X 10
7
Ω.
Less than 2 secs. from
initial value (Max.
1000 ) to 10%
ESD-safe item requirements
(Excerpted from RCJS-5-1:2014)
【
【【
【tem-specific requirements】
】】
】
Charge decay
*2
Gloves and
finger cots
EPA ground resistance
or Resistance Rg(
Ω
) of
groundable point
Gloves and finger sacks
that satisfy the system requirements.
Using gloves
and finger cots
7.5×10
5
≦Rg
<1×10
12
【
【【
【System requirements】
】】
】