manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HP
  6. •
  7. Storage
  8. •
  9. HP Surestore Disk Array 12h - And FC60 Quick guide

HP Surestore Disk Array 12h - And FC60 Quick guide

Other manuals for Surestore Disk Array 12h - And FC60

19

This manual suits for next models

1

Other HP Storage manuals

HP Surestore Disk Array 12h - And FC60 User manual

HP

HP Surestore Disk Array 12h - And FC60 User manual

HP OmniBook 3100 - Notebook PC User manual

HP

HP OmniBook 3100 - Notebook PC User manual

HP ProLiant SB460c - SAN Gateway Storage Server User manual

HP

HP ProLiant SB460c - SAN Gateway Storage Server User manual

HP StoreOnce B6000 User manual

HP

HP StoreOnce B6000 User manual

HP 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive... User manual

HP

HP 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive... User manual

HP StorageWorks AiO600 User instructions

HP

HP StorageWorks AiO600 User instructions

HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard... Guide

HP

HP 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard... Guide

HP StorageWorks ESL E Series Use and care manual

HP

HP StorageWorks ESL E Series Use and care manual

HP Brio 71xx User manual

HP

HP Brio 71xx User manual

HP C7745NB - SureStore DLT Tape Autoloader 1/9 User manual

HP

HP C7745NB - SureStore DLT Tape Autoloader 1/9 User manual

HP HD1600 User manual

HP

HP HD1600 User manual

HP Compaq Presario,Presario 4400 Guide

HP

HP Compaq Presario,Presario 4400 Guide

HP StorageWorks XP12000 User manual

HP

HP StorageWorks XP12000 User manual

HP surestore dat 2000i User manual

HP

HP surestore dat 2000i User manual

HP C2233 User manual

HP

HP C2233 User manual

HP DW017B - StorageWorks Ultrium 448 Tape Drive Instruction Manual

HP

HP DW017B - StorageWorks Ultrium 448 Tape Drive Instruction Manual

HP AA988A - Modular Smart Array Storage Controller... User manual

HP

HP AA988A - Modular Smart Array Storage Controller... User manual

HP 5243 User manual

HP

HP 5243 User manual

HP StoreAll 8800 Service manual

HP

HP StoreAll 8800 Service manual

HP P9000 User manual

HP

HP P9000 User manual

HP Surestore 160ex - Optical Jukebox User manual

HP

HP Surestore 160ex - Optical Jukebox User manual

HP AJ765A - StorageWorks RDX Removable Disk Backup... User manual

HP

HP AJ765A - StorageWorks RDX Removable Disk Backup... User manual

HP StoreOnce D2D2500 User manual

HP

HP StoreOnce D2D2500 User manual

HP IBRIX X9720 Service manual

HP

HP IBRIX X9720 Service manual

Popular Storage manuals by other brands

QNAP TS 32PXU Series user guide

QNAP

QNAP TS 32PXU Series user guide

LaCie RUGGED RAID user manual

LaCie

LaCie RUGGED RAID user manual

Freecom CLS DOCK Quick install guide

Freecom

Freecom CLS DOCK Quick install guide

PNY Attache P-FD64MBATT3 install guide

PNY

PNY Attache P-FD64MBATT3 install guide

OLT 6x6 Maximizer Assembly manual

OLT

OLT 6x6 Maximizer Assembly manual

Transcend JetFlash 160 Specifications

Transcend

Transcend JetFlash 160 Specifications

LaCie RUGGED MINI user manual

LaCie

LaCie RUGGED MINI user manual

Thunderbolt 600 user manual

Thunderbolt

Thunderbolt 600 user manual

Panasonic LB-DH8 series Operator's guide

Panasonic

Panasonic LB-DH8 series Operator's guide

Intel RAID High Availability user guide

Intel

Intel RAID High Availability user guide

LaCie 12big Thunderbolt 3 Quick install guide

LaCie

LaCie 12big Thunderbolt 3 Quick install guide

Spectra Logic T-Series Spectra T50e quick start guide

Spectra Logic

Spectra Logic T-Series Spectra T50e quick start guide

Panasonic LKM-F931-1 instruction manual

Panasonic

Panasonic LKM-F931-1 instruction manual

Tabernus Enterprise Erase E2400 user guide

Tabernus

Tabernus Enterprise Erase E2400 user guide

Rocstor COMMANDER 3F series user manual

Rocstor

Rocstor COMMANDER 3F series user manual

Western Digital Ultrastar Data60 installation guide

Western Digital

Western Digital Ultrastar Data60 installation guide

Dell PowerVault MD3600f Series Getting started

Dell

Dell PowerVault MD3600f Series Getting started

CFI TERA STOR SATA RAID IV user manual

CFI

CFI TERA STOR SATA RAID IV user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

A5277AZ Factory Configuration for 1 Disk Enclosure
Recommended FC60 Configuration
Single host, dual-controller disk array, 1 disk enclosure, 5 RAID 1 LUNs
FCAL-B
LVD
SCSI LVD
SCSI
FCAL-A
Red and Blue drives are on separate SCSI buses
LUN 0 LUN 1 LUN 2 LUN 3 LUN 4
FC60 Enclosure
Controller A Controller B
SC10 Disk Enclosure
BCC A
BCC B
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–One disk enclosures with ten 18 GB disk modules in each
–Disk enclosure set to split-bus mode by setting option
switch 1 DOWN on BCCs
–Unused SCSI connectors on FC60 enclosure must be terminated
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Five RAID 1 LUNs, comprising 2 disks each (1+1)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, or SCSI channel
–Does not handle the failure of the disk enclosure
Disk Capacity
–Maximum capacity ~180 GB
–Usable capacity ~90 GB
Host
FC Adapter A FC Adapter B
Recommended FC60 HA Configuration
Single host, dual-controller disk array, 2 disk enclosures, 10 RAID 1 LUNs
SC10 Disk Enclosures
FCAL-B
LVD
SCSI LVD
SCSI
FCAL-A
Red and Blue drives are on separate SCSI buses
LUN 0 1 2 3 4
FC60 Enclosure
Controller A Controller B
BCC A
BCC BBCC B
BCC A
57689
A5277AZ Factory Configuration for 2 Disk Enclosures
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–Two disk enclosures with ten 18 GB disk modules in each
–Disk enclosures set to split-bus mode by setting option
switch 1 DOWN on BCCs
–Unused SCSI connectors on FC60 enclosure must be terminated
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Ten RAID 1 LUNs, comprising 2 disks each (1+1)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, SCSI channel,
or disk enclosure
–Disk Capacity
–Maximum capacity ~360 GB
–Usable capacity ~180 GB
Host
FC Adapter A FC Adapter B
Recommended FC60 HA Configuration
Single host, dual-controller disk array, 3 disk enclosures, 15 RAID 1 LUNs
FCAL-B
LVD
SCSI LVD
SCSI
FCAL-A
Red and Blue drives are on separate SCSI buses
SC10 Disk Enclosures
BCC B
BCC ABCC ABCC A
BCC B BCC B
LUN 0 1 LUN 9234 5678
A5277AZ Factory Configuration for 3 Disk Enclosures
FC60 Enclosure
Controller A Controller B
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–Three disk enclosures with ten 18 GB disk modules in each
–Disk enclosures set to split-bus mode by setting option
switch 1 DOWN on BCCs
–Unused SCSI connectors on FC60 enclosure must be terminated
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Fifteen RAID 1 LUNs, comprising 2 disks each (1+1)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, SCSI channel,
or disk enclosure
–Disk Capacity
–Maximum capacity ~540 GB
–Usable capacity ~270 GB
Host
FC Adapter A FC Adapter B
Recommended FC60 HA Configuration
Single host, dual-controller disk array, 4 disk enclosures, 10 RAID 0/1 LUNs
FCAL-B
FCAL-A
LUN 0 LUN 1 LUN 2 LUN 3 LUN 4 LUN 5 LUN 6 LUN 7
SC10 Disk Enclosures
BCC A
BCC ABCC A
BCC A
LUN 8 LUN 9
BCC B BCC B BCC B BCC B
A5277AZ Factory Configuration for 4 Disk Enclosures
FC60 Enclosure
Controller A Controller B
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–Four disk enclosures with ten 18 GB disk modules in each
–Disk enclosures set to full-bus mode by setting option switch 1 UP on BCCs
–Unused SCSI connectors on FC60 enclosure must be terminated
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Ten RAID 0/1 LUNs, comprising 4 disks each (2+2)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, SCSI channel,
or disk enclosure
–Very high availability for single failures
Disk Capacity
–Maximum capacity ~720 GB
–Usable capacity ~360 GB
Host
FC Adapter A FC Adapter B
Single host, dual-controller disk array, 5 disk enclosures, 10 RAID 0/1 & 5 RAID 1 LUNs
FCAL-B
FCAL-A
SC10 Disk Enclosures
BCC ABCC ABCC ABCC A BCC A
BCC B BCC B
BCC B
BCC BBCC B
A5277AZ Factory Configuration for 5 Disk Enclosures
Recommended FC60 HA Configuration
FC60 Enclosure
Controller A Controller B
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–Five disk enclosures with ten 18 GB disk modules in each
–Disk enclosures set to full-bus mode by setting option switch 1 UP on BCCs
–Unused SCSI connectors on FC60 enclosure must be terminated
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Ten RAID 0/1 LUNs, comprising 4 disks each (2+2)
–Five RAID 1 LUNs, comprising 2 disk each (1+1)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, SCSI channel,
or disk enclosure
–Very high availability for single failures
Disk Capacity
–Maximum capacity ~900 GB
–Usable capacity ~450 GB
Host
FC Adapter A FC Adapter B
Recommended FC60 HA Configuration
Single host, dual-controller disk array, 6 disk enclosures, 10 RAID 0/1 LUNs
FCAL-B
FCAL-A
LUN 0 LUN 1 LUN 2 LUN 3 LUN 4 LUN 5 LUN 6 LUN 7
SC10 Disk Enclosures
BCC ABCC ABCC ABCC A BCC A BCC A
LUN 8 LUN 9
BCC B BCC BBCC BBCC B
BCC B
BCC B
A5277AZ Factory Configuration for 6 Disk Enclosures
FC60 Enclosure
Controller A Controller B
Hardware Configuration
–FC60 controllers connected directly to host FC adapters
–Six disk enclosures with ten 18 GB disk modules in each
–Disk enclosures set to full-bus mode by setting option switch 1 UP on BCCs
–Expansion SCSI connector on disk enclosure must be terminated
LUN Configuration
– Ten RAID 0/1 LUNs, comprising 6 disks each (3+3)
–Each disk in the LUN is in a separate enclosure
High Availability
–Handles the failure of a single disk, controller, BCC, SCSI channel,
or disk enclosure
–Very high availability for single failures
Disk Capacity
–Maximum capacity ~1080 GB
–Usable capacity ~540 GB
Host
FC Adapter A FC Adapter B