manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hubbell
  6. •
  7. Protection Device
  8. •
  9. Hubbell HBL3W50 Training manual

Hubbell HBL3W50 Training manual

This manual suits for next models

1

Other Hubbell Protection Device manuals

Hubbell Spikeshield HBL3P120C Training manual

Hubbell

Hubbell Spikeshield HBL3P120C Training manual

Hubbell Circuit Guard GFP15M User manual

Hubbell

Hubbell Circuit Guard GFP15M User manual

Hubbell SPIKESHIELD HBL3P120B User manual

Hubbell

Hubbell SPIKESHIELD HBL3P120B User manual

Popular Protection Device manuals by other brands

Sola HD STV100K Series instruction manual

Sola HD

Sola HD STV100K Series instruction manual

socomec COUNTIS AMd operating instructions

socomec

socomec COUNTIS AMd operating instructions

Kemo Electronic M148-24 instructions

Kemo Electronic

Kemo Electronic M148-24 instructions

SK ClickClick user manual

SK

SK ClickClick user manual

Endress+Hauser HAW569 quick start guide

Endress+Hauser

Endress+Hauser HAW569 quick start guide

Ultrasonic SonicPRO installation manual

Ultrasonic

Ultrasonic SonicPRO installation manual

nxt BIA-nXt-DPC 1-22 Installation and operation manual

nxt

nxt BIA-nXt-DPC 1-22 Installation and operation manual

TFortis SG-Switch operating manual

TFortis

TFortis SG-Switch operating manual

BERNINI DESIGN Be172 instruction manual

BERNINI DESIGN

BERNINI DESIGN Be172 instruction manual

Rayleigh Instruments RI-ENERGYSET-3P-ESS-50-100 manual

Rayleigh Instruments

Rayleigh Instruments RI-ENERGYSET-3P-ESS-50-100 manual

E.K.T. ke-DP01 quick start guide

E.K.T.

E.K.T. ke-DP01 quick start guide

Siemens SIPROTEC 7SD80 manual

Siemens

Siemens SIPROTEC 7SD80 manual

cias MICRO-RAY installation manual

cias

cias MICRO-RAY installation manual

Sungrow PVS-16MH user manual

Sungrow

Sungrow PVS-16MH user manual

Reer 32010 instruction manual

Reer

Reer 32010 instruction manual

Tyco ESFR-17 quick start guide

Tyco

Tyco ESFR-17 quick start guide

Ross Opengear SRA-8901-R user guide

Ross

Ross Opengear SRA-8901-R user guide

GE Multilin 850 instruction manual

GE

GE Multilin 850 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instruction Bulletin
WARNING
INADEQUATE GROUNDING HAZARD
Do not use on ungrounded systems.
Failure to follow these instructions can result in death or serious injury.
CAUTION
HAZARD OF EQUIPMENT DAMAGE
Megger ®or hi-potential tests will damage this surge protective
equipment and isolate the surge protective device before testing.
Failure to follow these instructions can result in equipment damage.
PRECAUTIONS DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
· Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices.
See NFPA 70E.
· This equipment must only be installed and serviced by qualified electrical personnel.
· Turn off all power supplying this equipment before working on or inside equipment.
· Always use a properly rated voltage sensing device to confirm power is off.
· Replace all devices, doors and covers before turning on power to this equipment.
Failure to follow these instructions will result in death or serious injury.
This equipment must be effectively grou
equipment to the power system ground.
·nded per all applicable codes. Use an equipment grounding
conductor to connect this
The HBL3W120 and HBL3W50 Surge Protective Devices (SPDs) are designed to provide protection
at service entrance panels, load centers or electronic compartments.
INTRODUCTION
device. Turn off all power supplying the
HuBBell
Surge Protective DeviceS
HBL3W120
HBL3W50
8291-0086A
02/2009
Retain for future use.
LED ON = OK
Figure 3: Diagnostic Operation
Figure 4: Dimensions
3.75
[95]
3.60
[91]
3.00
[76]
0.87
[22]
2.67
[68]
Dimensions: in.
[mm]
Single-phase 3-wire
(+GND) 120/240 Vac
0.5 in. [13 mm] knockout (trade size)
Actual hole size 0.875 in. [22 mm]
an accessible location (not within walls).
1. Turn off all power supplying this equipment before working on or
inside equipment.
2. For mounting, see Figure 1.
3. Confirm SPD is rated for your system by comparing voltage
measurements to the Line Voltage (L-L, L-N) on the product label.
4. Confirm the black wires are connected to line wires, the white wire
to the neutral wire and green wire to ground (see figure 2). For the
5. Twist conductors 1/2 turn or more for every 12 inches of length.
6. Keep conductor length as short as possible with no sharp bends.
7. Do not loop or coil wires.
8. Use on solidly grounded systems only.
General Specifications
Short Circuit Current Rating 25 kA
I
Enclosure Rating Type 4X
Product Weight 1.8 lbs (0.9kg)
Connection Method Parallel, #12 AWG Solid Wire
Thermal Fusing Yes
Operating Temperature -40° to +160° F (-40° to +70° C)
Operating Frequency 50/60 Hz
Diagnostics Green Status LED per line
Product Standards UL 1449-3rd Edition, CSA C22.2 No. 8-M1986,
Figure 1: Mounting Unit
Single-phase 2-wire
(+GND) 120 Vac
INSTALLATION
VPR 700V L1-N, 700V L1-G, 700V L2-N, 800V L2-G
System Voltage 120/240VAC
MCOV 150VAC
Product Rating Type 1 SPD
(n)
CSA C233.1-87 and CE
Nut
NOTE: The Surge Protective Device must be installed in
Black
Green
Black
White
L1
N
L2
Green
Black
White
L
N
LED ON = Normal Operation
LED OFF = Check breakers and connections.
Verify line voltage at point of SPD connection;
Iif all correct replace SPD
Panel
0.5 in. [13 mm] knockout (trade size)
Actual hole size 0.875 in. [22 mm]
single-phase, 120/240V 3-wire application, connect one of the SPD
black wires to L1 and the other black wire to L2. For the single-
phase, 120V 2-wire application, connect both SPD black wires
to the same line.
Figure 2 : Wiring Diagrams
LED OFF = Fault, L1 and/or L2
1. Suitable for use on a circuit capable of delivering not more than 25 kA rms symmetrical Amperes.
2. Contains no serviceable parts.
10kA (L1-N, L1-G, L2-N, L2-G)
Models Voltage Mounting
HBL3W120
Side Nipple
120/240
Side Nipple
HBL3W50
Surge + Overvoltage
Protection
Surge + Overvoltage
Max Surge
Current
120kA
50kA
120/240
2Hubbell Modular Panel Surge Protective Device (SPD)
Hubbell Hardwired Surge Protective Device (SPD)
INSTAllATION
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Hubbell for any consequences arising out of the use of this material.
Hubbell Wiring Devices
1-800-729-3406 | www.Hubbell-Wiring.com