Arc Adjustment
(All PGJ adjustable heads are PRESET to
approximately 40°)
1. Rotate the nozzle turret counterclockwise
to the left stop.
2. Now, rotate the nozzle turret clockwise to
the right stop. This is the xed side of the
arc. The nozzle turret must be held in this
position for all arc adjustments.
To increase arc:
1. Insert the key end of the Hunter wrench
into the adjustment socket on top of the
sprinkler.
2. While holding the nozzle turret at the right
stop, turn the wrench clockwise.
3. Wrench will stop turning when adjusted to
the maximum arc (360°). Do not go past
this stop.
4. Adjust to any arc between 40°-360°.
To decrease arc:
1. Insert the key end of the Hunter wrench
into the adjustment socket.
2. While holding the nozzle turret at the right
stop, turn the wrench counterclockwise.
3. Wrench will stop turning when adjusted to
the minimum arc (40°). Do not go past this
stop.
4. Adjust to any arc between 40°-360°.
Radius Adjustment
To decrease radius:
1. Turn nozzle-retainer/range-adjustment
screw clockwise using hex end of Hunter
tool or slot screwdriver. This can reduce
radius up to 25%.
2. If an even smaller radius is desired, install
a smaller nozzle. This will affect precipita-
tion rate.
To increase radius:
1. Turn nozzle-retainer/range-adjustment
screw counterclockwise using hex end of
Hunter tool or slot screwdriver.
2. If larger radius is desired, install larger
nozzle. This will affect precipitation rate.
Precipitation Rate Adjustment
To increase precipitation:
1. Remove existing nozzle.
2. Replace with larger size.
3. Adjust radius.
To decrease precipitation:
1. Remove existing nozzle.
2. Replace with smaller size.
3. Adjust radius.
Note: Undamaged nozzles are reusable.
PGJ
Gear Driven Sprinklers
Hunter Industries Incorporated • The Irrigation Innovators
© 2004 Hunter Industries Incorporated
www.HunterIndustries.com P/N 700974 LIT-379 3/04
Fig. 3
Nozzle/Range
Adjustment
Screw
Lifting
Socket
Adjustment
Socket
Model
Identification
®
Fig.
Radius Reduction Screw
cke
®
PGJ
Nozzle
ID. Tab
Adjustmen
t
Radius Reduction Screw
Plus+
Minus-
Arc Adjustment
Pull-up
Socket
V
M
A
D
E
I
N
U
S
A
Plus+ Minus-- Arc Adjustment
Pull-up
Socket
Nozzle Installation
1. Insert the plastic key end of the Hunter
wrench into the lifting socket of the sprin-
kler and turn 90°. Pull the riser up to gain
access to the nozzle socket.
2. Using the hex key of the Hunter wrench,
turn the radius adjustment screw coun-
terclockwise to be sure it is not blocking
the nozzle socket opening. If a nozzle is
already installed, it can be removed by
backing out the adjustment screw and
turning on the water, or by prying outward
under the nozzle.
3. Slip the desired nozzle into the nozzle
socket. Note that the socket is angled up
Data represented test results in zero wind. Adjust for local conditions. Radius may be reduced up to 25% with adjustment screw (this may alter the uniformity of spray pattern).
Optimum performance is shown in bold type.
For warranty information on Hunter Sprinklers, consult factory.
PGJ
Gear Driven Sprinklers
PGJ Nozzle Performance Data
Pressure Radius Flow Precip in/hr
Nozzle PSI ft. GPM
.75
30
40
50
15'
16'
17'
0.64
0.75
0.85
0.55
0.56
0.57
0.63
0.65
0.65
1.0
30
40
50
18'
19'
19'
0.85
1.0
1.1
0.51
0.53
0.59
0.58
0.62
0.68
1.5
30
40
50
21'
22'
22'
1.3
1.5
1.7
0.57
0.60
0.68
0.66
0.69
0.78
2.0
30
40
50
24'
25'
25'
1.7
2.0
2.3
0.57
0.62
0.71
0.66
0.71
0.82
2.5
30
40
50
27'
28'
28'
2.2
2.5
2.8
0.58
0.61
0.69
0.67
0.71
0.79
3.0
30
40
50
30'
31'
31'
2.5
3.0
3.4
0.53
0.60
0.68
0.62
0.69
0.79
4.0
30
40
50
33'
34'
34'
3.7
4.0
4.3
0.65
0.67
0.72
0.76
0.77
0.83
5.0
30
40
50
36'
37'
37'
4.7
5.0
5.3
0.70
0.70
0.75
0.81
0.81
0.86
Note: All precipitation rates calculated for 180 degree operation.
For the precipitation rate for a 360 degree sprinkler, divide by 2.
PGJ Nozzle Performance Data – Metric
Pressure Radius Flow Precip mm/hr
Nozzle Bars kPa m m3/hr l/min
.75
2.1
2.8
3.4
206
275
344
4.6
4.9
5.2
0.15
0.17
0.19
2.4
2.8
3.2
14
14
14
16
17
17
1.0
2.1
2.8
3.4
206
275
344
5.5
5.8
5.8
0.19
0.23
0.25
3.2
3.8
4.2
13
14
15
15
16
17
1.5
2.1
2.8
3.4
206
275
344
6.4
6.7
6.7
0.30
0.34
0.39
4.9
5.7
6.4
14
15
17
17
18
20
2.0
2.1
2.8
3.4
206
275
344
7.3
7.6
7.6
0.39
0.45
0.52
6.4
7.6
8.7
14
16
18
17
18
21
2.5
2.1
2.8
3.4
206
275
344
8.2
8.5
8.5
0.50
0.57
0.64
8.3
9.5
10.6
15
16
18
17
18
20
3.0
2.1
2.8
3.4
206
275
344
9.1
9.4
9.4
0.57
0.68
0.77
9.5
11.4
12.9
14
15
17
16
18
20
4.0
2.1
2.8
3.4
206
275
344
10.1
10.4
10.4
0.84
0.91
0.98
14.0
15.1
16.3
17
17
18
19
20
21
5.0
2.1
2.8
3.4
206
275
344
11.0
11.3
11.3
1.07
1.14
1.20
17.8
18.9
20.1
18
18
19
21
21
22
Note: All precipitation rates calculated for 180 degree operation.
For the precipitation rate of a 360 degree sprinkler, divide by 2.
For more information on precipitation rates see page 105.
25° so that the nozzle range screw threads
directly down. Then tighten the nozzle
range screw. The arrow on the rubber
cover will always indicate the location of
the nozzle and direction of the water ow
when the sprinkler is retracted.
Removing Filter Screen
for Cleaning
Proper Installation
Height

Other Hunter Irrigation System manuals

Hunter I-25 Ultra User manual

Hunter

Hunter I-25 Ultra User manual

Hunter Sprinkler System Guide

Hunter

Hunter Sprinkler System Guide

Hunter I-25 User manual

Hunter

Hunter I-25 User manual

Hunter i-core IC-600PL User manual

Hunter

Hunter i-core IC-600PL User manual

Hunter I-20 ULTRA User manual

Hunter

Hunter I-20 ULTRA User manual

Hunter ST Series User manual

Hunter

Hunter ST Series User manual

Hunter Professional PGP Ultra Series User manual

Hunter

Hunter Professional PGP Ultra Series User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter INSTITUTIONAL SERIES I-90 User manual

Hunter

Hunter INSTITUTIONAL SERIES I-90 User manual

Hunter PGJ Rotor User manual

Hunter

Hunter PGJ Rotor User manual

Hunter ST Series User manual

Hunter

Hunter ST Series User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter Institutional Series I-25 Plus User manual

Hunter

Hunter Institutional Series I-25 Plus User manual

Hunter I-80 User manual

Hunter

Hunter I-80 User manual

Hunter ST Series User manual

Hunter

Hunter ST Series User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter XC Hybrid User manual

Hunter

Hunter XC Hybrid User manual

Hunter PRO-C Hydrawise User manual

Hunter

Hunter PRO-C Hydrawise User manual

Hunter Professional PGP User manual

Hunter

Hunter Professional PGP User manual

Hunter Professional Series PGP User manual

Hunter

Hunter Professional Series PGP User manual

Hunter X-CORE Operating instructions

Hunter

Hunter X-CORE Operating instructions

Hunter TTS-800 Series User manual

Hunter

Hunter TTS-800 Series User manual

Hunter G835 User manual

Hunter

Hunter G835 User manual

Hunter Hydrawise Ready User manual

Hunter

Hunter Hydrawise Ready User manual

Popular Irrigation System manuals by other brands

Tyco Fire Product CENTRAL A instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL A instruction manual

Reliable DH80 Dry manual

Reliable

Reliable DH80 Dry manual

Toro TMC-424 Series brochure

Toro

Toro TMC-424 Series brochure

viRaTec Miyo SMART GARDEN technical information

viRaTec

viRaTec Miyo SMART GARDEN technical information

Tyco Fire Product CENTRAL K25-1 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL K25-1 instruction manual

Tyco Fire Product Star Galaxy SG instruction manual

Tyco Fire Product

Tyco Fire Product Star Galaxy SG instruction manual

Viking 300TB-IP product manual

Viking

Viking 300TB-IP product manual

Reliable F1FR – 300 quick start guide

Reliable

Reliable F1FR – 300 quick start guide

Globe GL4231 quick start guide

Globe

Globe GL4231 quick start guide

Tyco Gem PSN 56-701-9-010 manual

Tyco

Tyco Gem PSN 56-701-9-010 manual

Lux Tools EWSU-8 B Original instructions

Lux Tools

Lux Tools EWSU-8 B Original instructions

Reliable F1FR56 quick start guide

Reliable

Reliable F1FR56 quick start guide

Reliable HL22 Bulletin

Reliable

Reliable HL22 Bulletin

Viking HORIZON MIRAGE Technical data

Viking

Viking HORIZON MIRAGE Technical data

Sime JUNIOR INSTALLATION, USE, MAINTENANCE, SPARE PARTS

Sime

Sime JUNIOR INSTALLATION, USE, MAINTENANCE, SPARE PARTS

Senju Sprinkler ZN-UF Operation instructions

Senju Sprinkler

Senju Sprinkler ZN-UF Operation instructions

CENTRAL ELO-16 GB FR OH manual

CENTRAL

CENTRAL ELO-16 GB FR OH manual

Cellfast POWER TT IDEAL 52-066 user manual

Cellfast

Cellfast POWER TT IDEAL 52-066 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.