Fig. 1
®
ARC ADJUSTMENTS
Adjustable heads are preset to approximately 180°.
Sprinklers may be adjusted with water on or off. It is
recommended that initial adjustment be made
before installation.
1. Using the palm of your hand, rotate the
nozzle turret counterclockwise to the left stop
to complete any interrupted rotation cycle
(Fig. 1).
2. Rotate the nozzle turret clockwise to the right
stop. This is the fixed side of the arc. The
nozzle turret must be held in this position for
all arc adjustments.
To Increase the Arc:
1. Insert the key end of the Hunter wrench into
the adjustment socket (Figs. 2 & 3).
Insert the key end of the Hunter wrench
into the lifting socket of the sprinkler. Pull the
riser up to gain access to the nozzle socket.
Using the Hunter wrench, loosen the
nozzle/range-adjustment screw. If a nozzle
is already installed in the sprinkler, it can be
removed by briefly turning on the water, or
by pulling on one of the nozzle “ears” with
needle-nose pliers.
Slip the desired nozzle into the nozzle
socket. Note that the socket is angled up
25°. Also note that the “ears” should be
located at the top (Fig. 4). Tighten the
nozzle/range-adjustment screw.
1.
2.
3.
NOZZLE INSTALLATIONRADIUS ADJUSTMENT
Insert the hex end of the Hunter wrench into
the nozzle/range-adjustment screw (Figs. 2 &
3). Turn the screw clockwise (into the stream
of water) to decrease the radius, or
counterclockwise to increase the radius.
PRECIPITATION RATE ADJUSTMENT
For excessively wet or dry areas, the
precipitation rate can be adjusted—simply
replace the existing nozzle with a larger one to
increase, or a smaller one to decrease, the rate
of precipitation.
Note: It is not necessary to disassemble
the sprinkler to make adjustments.
®
Professional Series
PGP, PGS, PGH
Gear-Driven Sprinklers
2. While holding the nozzle turret at the right stop,
turn the wrench clockwise. Each full turn of the
wrench increases the arc 90°.
3. Adjust to any arc between 40°and 360°.
4. Wrench will stop turning or there will be a
ratcheting noise, when the maximum arc (360°)
is reached.
To Decrease the Arc:
1. Insert the key end of the Hunter wrench into the
adjustment socket (Figs. 2 & 3).
2. While holding the nozzle turret at the right stop,
turn the wrench counterclockwise. Each full
turn of the wrench decreases the arc 90°.
3. Adjust to any arc between 40°and 360°.
4. Wrench will stop turning, or there will be a
ratcheting noise, when the minimum arc (40°)
is reached.
Fig. 4
Fig. 2
Fig. 3
Nozzle/Range-
Adjustment
Screw
Lifting
Socket
Adjustment
Socket
Nozzle
Turret Nozzle
Socket
ID Button
Hunter Industries Incorporated • The Irrigation Innovators © 2001 Hunter Industries Incorporated
U.S.A.: 1940 Diamond Street • San Marcos, California 92069 • TEL: (1) 760-744-5240 • FAX: (1) 760-744-7461 • www.HunterIndustries.com P/N 700026
Australia: 8 The Parade West • Kent Town, S. Australia 5067 • TEL: (61) 8-8363-3599 • FAX: (61) 8-8363-3687 INT-026.PDF
Europe: Europarc, Bât. B14 • 1330, rue G. de la Lauzières • 13855 Aix-en-Provence, France • TEL: (33) 4-42-93-03-68 • FAX: (33) 4-42-93-03-84 7/01
7
8
9
10
11
12
1
2
3
4
5
6
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,8
3,4
4,1
4,8
2,8
3,4
4,1
4,8
2,8
3,4
4,1
4,8
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
275
344
413
482
275
344
413
482
275
344
413
482
0,11
0,14
0,16
0,18
0,16
0,18
0,20
0,23
0,20
0,23
0,27
0,30
0,27
0,32
0,36
0,41
0,36
0,41
0,45
0,50
0,45
0,55
0,61
0,66
0,59
0,68
0,77
0,84
0,73
0,84
0,95
1,04
0,95
1,11
1,25
1,36
1,36
1,54
1,73
1,86
1,82
2,02
2,23
2,39
2,59
2,77
3,00
3,27
1,9
2,3
2,7
3,0
2,6
3,0
3,4
3,8
3,4
3,8
4,5
4,9
4,5
5,3
6,1
6,8
6,1
6,8
7,6
8,3
7,6
9,1
10,2
11,0
9,8
11,4
12,9
14,0
12,1
14,0
15,9
17,4
15,9
18,5
20,8
22,7
22,7
25,7
28,8
31,0
30,3
33,7
37,1
39,7
43,2
46,2
50,0
54,5
8,5
8,8
8,8
9,1
8,8
9,1
9,1
9,4
9,1
9,4
9,4
9,8
9,8
10,1
10,4
10,4
10,4
11,0
11,6
11,6
11,0
11,6
12,2
12,2
11,0
12,2
12,8
12,8
11,3
12,2
13,1
13,4
11,6
13,1
14,0
14,3
13,7
14,6
14,9
15,5
14,0
14,6
15,2
15,5
14,0
14,6
15,2
15,9
Nozzle
m
3
/hr.
kPaBars l/min
Radius
m
Pressure
Flow
Performance Data
Matched Precipitation
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
206
275
344
413
275
344
413
482
0,32
0,39
0,41
0,45
0,36
0,43
0,48
0,52
0,48
0,57
0,64
0,68
0,64
0,70
0,80
0,86
0,77
0,89
1,00
1,07
0,98
1,14
1,27
1,39
1,48
1,66
1,82
1,95
5,3
6,4
6,8
7,6
6,1
7,2
7,9
8,7
7,9
9,5
10,6
11,4
10,6
11,7
13,2
14,4
12,9
14,8
16,7
17,8
16,3
18,9
21,2
23,1
24,6
27,6
30,3
32,6
6,7
7,3
7,9
8,5
7,6
8,2
8,5
9,1
8,2
9,1
10,1
10,7
8,8
9,8
10,7
11,3
9,4
10,4
11,3
11,6
10,1
11,3
12,2
12,8
11,6
12,2
12,8
13,4
8
9
10
P
4
7
5
6
Blank nozzle plug for turning off
selected sprinklers during repairs,
maintenance, etc.
m3/hr.
kPaBars l/min
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,1
2,8
3,4
4,1
2,8
3,4
4,1
4,8
m
3
/hr. l/min
Flow m
3
/hr. l/min
Flow
90°
Nozzle #
180°
Nozzle # 360°
Nozzle #
m
3
/hr. l/min
Flow
PGS, PGP, PGH Performance Chart PGS, PGP, PGH Low Angle Chart
Nozzle
Radius
m
Pressure Flow
Square
Spacing
When the spacing/arc/nozzle pressure combinations are spaced as indicated, the precipitation rate
will be approximately 10 mm/hr. at 3,4 bars/344 kPa.
1
0 mm/hr at 3,4 bars/344 kPa
1
2
3
4
5
0,16
0,20
0,27
0,36
0,45
2,7
3,4
4,5
6,1
7,6
4
5
6
7
8
6
8
9
10
11
7,6 m
9,1 m
10,7 m
12,2 m
13,7 m
0,77
0,95
1,25
1,73
2,23
12,9
15,9
20,8
28,8
37,1
0,36
0,45
0,61
0,77
0,95
6,1
7,6
10,2
12,9
15,9

This manual suits for next models

3

Other Hunter Irrigation System manuals

Hunter Institutional Series I-35 User manual

Hunter

Hunter Institutional Series I-35 User manual

Hunter Institutional I-40 User manual

Hunter

Hunter Institutional I-40 User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter G835 User manual

Hunter

Hunter G835 User manual

Hunter I-80 User manual

Hunter

Hunter I-80 User manual

Hunter i-core IC-600PL User manual

Hunter

Hunter i-core IC-600PL User manual

Hunter Institutional I-20 User manual

Hunter

Hunter Institutional I-20 User manual

Hunter I-31 Plus User manual

Hunter

Hunter I-31 Plus User manual

Hunter Institutional Series I-90 User manual

Hunter

Hunter Institutional Series I-90 User manual

Hunter PRO-C Hydrawise User manual

Hunter

Hunter PRO-C Hydrawise User manual

Hunter I-80 User manual

Hunter

Hunter I-80 User manual

Hunter PGJ Rotor User manual

Hunter

Hunter PGJ Rotor User manual

Hunter ST Series User manual

Hunter

Hunter ST Series User manual

Hunter Hydrawise Ready User manual

Hunter

Hunter Hydrawise Ready User manual

Hunter Institutional Series I-25 Plus User manual

Hunter

Hunter Institutional Series I-25 Plus User manual

Hunter PGP Series User manual

Hunter

Hunter PGP Series User manual

Hunter ST Series User manual

Hunter

Hunter ST Series User manual

Hunter PGP Ultra Series User manual

Hunter

Hunter PGP Ultra Series User manual

Hunter Professional PGP Ultra Series User manual

Hunter

Hunter Professional PGP Ultra Series User manual

Hunter G800 Series User manual

Hunter

Hunter G800 Series User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter Institutional I-40 Series User manual

Hunter

Hunter Institutional I-40 Series User manual

Hunter Institutional Series User manual

Hunter

Hunter Institutional Series User manual

Hunter I-25 Ultra User manual

Hunter

Hunter I-25 Ultra User manual

Popular Irrigation System manuals by other brands

Tyco Fire Product CENTRAL ESFR-17 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ESFR-17 instruction manual

Tyco Fire Protection Products ESFR-17 manual

Tyco Fire Protection Products

Tyco Fire Protection Products ESFR-17 manual

G-Tools G-kit Bonanza 1m2 manual

G-Tools

G-Tools G-kit Bonanza 1m2 manual

Tyco ESFR-25 manual

Tyco

Tyco ESFR-25 manual

Rain i-dial instructions

Rain

Rain i-dial instructions

Autopot 12Pot XL Set-up guidelines

Autopot

Autopot 12Pot XL Set-up guidelines

Globe GL-QR/ECLH Series quick guide

Globe

Globe GL-QR/ECLH Series quick guide

Autopot AQUAvalve5 Simple care guidelines

Autopot

Autopot AQUAvalve5 Simple care guidelines

Autopot AquaValve 1Pot XL Set-up guidelines

Autopot

Autopot AquaValve 1Pot XL Set-up guidelines

Tyco Fire Product Gem A instruction manual

Tyco Fire Product

Tyco Fire Product Gem A instruction manual

Eden 94135EDAMZ manual

Eden

Eden 94135EDAMZ manual

Johnson Controls tyco ESFR-17 manual

Johnson Controls

Johnson Controls tyco ESFR-17 manual

Tyco Fire Product Star LD-2 instruction manual

Tyco Fire Product

Tyco Fire Product Star LD-2 instruction manual

Westfalia 85 62 46 instruction manual

Westfalia

Westfalia 85 62 46 instruction manual

Snapper 1695066 owner's manual

Snapper

Snapper 1695066 owner's manual

Tyco Fire Protection Products LD quick start guide

Tyco Fire Protection Products

Tyco Fire Protection Products LD quick start guide

Rain AMICO+ user manual

Rain

Rain AMICO+ user manual

Tyco Fire Product CENTRAL Omega HEC-12EC PRO instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL Omega HEC-12EC PRO instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.