Chapter1Introduction
Page 6 Definitions of Terms
Mobile Bain Maries
SPA/EB-1 |SPA/EB-2 |SPA/EB-2F |SPA/EB-2LS | SPA/EB-3 | SPA/EB-3F | SPA/EB-3LS |SPA/EB-4 4330002_A2
1.3 Definitions of Terms
Term Definition
Authorised specialist Anauthorised specialist is a specialist that has been trained by the manufacturer, an
authorised service dealeror a company assigned by the manufacturer.
Check,inspect Compare withcertain conditions and/or characteristics such as damage, leaks, filling
levels and heat.
cleaning system-resistant The suitabilityof the appliance for cleaning in anautomated washing device is limited.
It is possible to achieve a flawless, reproducible cleaning and drying result, but it
cannot be guaranteed.
The exteriorand interior housing are produced to standard versions. Water ingressing
hollow spaces resulting from the design of the appliance can run off without hi n-
drance. Water collectionin hollow spaces is avoided. Installed electrical components
and electrical wiring are protected byappropriate sealing (for example, labyrinthedg-
es, sealing profiles, cable channels) against any form of penetration by water. Protec-
tion class IPX6 (powerful pressurised water) to DIN EN 60529 (VDE 0470) is guaran-
teed. It is possible that water remains and is carried over following the drying process.
Convection Physicalproperties or mass transfer (e.g. heat or cold) throughcurrents ingases and
liquids.
Cook&ChillKitchens "Cook and Chill":Kitchens where warm food is cooled as quickly as possible after
being cooked.
Cook&Serve Kitchens "Cook and Serve":Kitchens where warm food is served immediatelyafter being
cooked or kept warm until it is consumed.
Corrosion The chemical reactionof a metallic material withits surroundings, e.g. rust.
Cover A bell-shapedcover for keeping food warm on plates and dishes.
Element formation Also:contactcorrosion. Occurs when different noble metals are inclose contact with
eachother. This happens when a corrosive medium is between both metals, such as
water or even normal air moisture.
EMfield Electrical, magnetic or electromagnetic field that is defined byits field intensity and
phase formation.
ENtray A Europeanstandard tray is a trayina standard size.
EN1/1 corresponds to 20.9x14.6'' (530×370 mm), EN 1/2 corresponds to 14.6x10.4''
(370×265 mm).
Gastronorm Gastronorm is a measurement system used worldwide inplaces such as food pro-
cessing plants or commercial kitchens. The use of standardised sizes makes it possi-
ble to exchange food pans. The basic size of the Gastronorm (GN) 1/1 is 20.9 x 12.8''
(530 × 325 mm). Items are available in different depths.
GN tray A Gastronorm standard tray is a standard-size tray.
GN 1/1 corresponds to 20.9x12.8'' (530×325 mm), GN 1/2 corresponds to 12.8x10.4''
(325×265 mm).
H1 Hygienic standard (NSF/USDA) for lubricants that are suitable for incidental and
technically unavoidable contact with foodstuffs.
HACCP HACCP is a preventive system that is designed to ensure the safety of foods and
consumers.
Instructed person Aninstructed personis a person who has beeninstructed onthe possible risks result-
ing from improper behaviour whencarrying outan assigned task and regarding the
necessary protective equipment and protective measures, and who has been trained
for this task, if necessary.
Lift A movement, for example a vertical movementof the guide basketfrombottom to top.
LMHV German Regulations on the Hygiene of Foodstuffs Regulations regarding hygiene
requirements for producing, handling and placing food on the market
Machinesafety The term machine safety refers to all the measures used to avertinjury to persons.
The basis for machine safetyis directives and laws for protecting users of technical
devices and systems valid nationallyand across the EC.
Passive layer A non-metallic protective layer on a metallic material that prevents or slows down
material corrosion.