Model Weight Height Width Dept
HWAM 2610c/2620c with plinth 66 kg 73.0 cm 43.0 cm 38.0 cm
HWAM 2610c/2620c with wall bracket 64 kg 70.0 cm 43.0 cm 40.4 cm
HWAM 2610c/2620c with pedestal 77 kg 100.0 cm 43.0 cm 38.0 cm
HWAM 2610m/2620m with plinth 64 kg 73.0 cm 43.0 cm 38.0 cm
HWAM 2610m/2620m with wall bracket 62 kg 70.0 cm 43.0 cm 40.4 cm
HWAM 2610m/2620m with pedestsal 75 kg 100.0 cm 43.0 cm 38.0 cm
HWAM 2630c/2640c 75 kg 100.0 cm 43.0 cm 38.0 cm
HWAM 2630m/2640m 73 kg 100.0 cm 43.0 cm 38.0 cm
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a non-
combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM
retailer for assistance.The combustion chamber opening is 27.7 cm wide.
Distance to combustible materials
If HWAM 2610/2620 is placed on a combustible floor, always mount it on a plinth whether or not the
floor is covered by a non-combustible material,such as a plate of glass or steel.The plinth is an accessory.
Contact your HWAM retailer for more information.
Min. distances - uninsulated flue gas pipe (drawing A) HWAM 2610
HWAM 2630
HWAM 2620
HWAM 2640
1. Recommended for brick wall 10 cm 10 cm
1. For combustible back wall 19 cm 19 cm
2. For combustible side wall 36 cm 36 cm
1.To combustible wall,corner installation, 45º* 34 cm* 20 cm*
3. Distance to furnishings in front 80 cm 80 cm
*All dimensions in connection with corner installation are only recommendations.For UK:Please consult
a qualified and competent Installer for clarification.
For wall-mounting, HWAM 2610/2620 must be placed at least 3 cm above any combustible flooring.This
also applies to any floorboard placed on the floor.
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM
®
Autopilot™. HWAM 2610/2620
may be mounted with wall fittings only on a brick wall.The stove must be taken down when the HWAM®
Autopilot™ is to be serviced.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance.As a general
rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80
cm above the ridge. If the chimney is placed at side walls, the top of the chimney should always be higher
than the ridge or the tallest point of the roof.Always be aware of any national and/or local regulations
applying to thatched roofs and the location of the chimneys.
The woodburning stove requires a minimum draught of 12 Pa (measured at EN 13240 measurement