If any signs of slippage are detected the swage joint must
be rejected and replaced.
For mechanically fixed end and intermediate anchors
secured to structural steelwork the fixing bolts shall be
subjected to a torque check to the recommended values.
If the tightening torque value is not achieved the fixing
bolts shall be replaced.
For systems supplied in kit form by the swaged
connections between the absorber or termination
and cable has been proof tested to 15kN.
Therefore, the system can be directly installed on to the
structure without the need for proof testing on site
provided the maximum predicted end load does not
exceed 15 kN. If the predicted end load is greater than 15
kN then a proof test to the maximum predicted end load
shall be carried out as described below.
For systems supplied as individual parts the swage
connection will need to be completed on site using the
recommended hexagonal dies with a minimum of 3 swage
bites. The connection shall be proof tested to the
maximum predicted end load before installation of the
system. After swaging it is recommended that the across
flats dimension is checked. The maximum across flats
dimension is 11.2 mm. Any swages greater than 11.2 mm
must be rejected.
It is recommended that the Hydrajaws test kit is used to
perform all the proof tests described below.
For swage testing, apply the recommended test load and
hold for 3 minutes, checking for any slippage of the cable
from the swage. This will be indicated by the gauge not
holding load and separation of the swage slip indicator
(85025) away from the end of the swage termination.
14. Test Load