manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HydroLogic
  6. •
  7. Water Filtration System
  8. •
  9. HydroLogic HL 33021 User manual

HydroLogic HL 33021 User manual

This manual suits for next models

1

Other HydroLogic Water Filtration System manuals

HydroLogic EvolitionRO1000 User manual

HydroLogic

HydroLogic EvolitionRO1000 User manual

HydroLogic W-MFI1665GET Operating manual

HydroLogic

HydroLogic W-MFI1665GET Operating manual

HydroLogic TallBoy HL-31050 User manual

HydroLogic

HydroLogic TallBoy HL-31050 User manual

HydroLogic smallBoy HGC728875 User manual

HydroLogic

HydroLogic smallBoy HGC728875 User manual

HydroLogic stealthRO150 User manual

HydroLogic

HydroLogic stealthRO150 User manual

HydroLogic StealthRO 300 User manual

HydroLogic

HydroLogic StealthRO 300 User manual

HydroLogic EvolutionRo User manual

HydroLogic

HydroLogic EvolutionRo User manual

HydroLogic micro75 User manual

HydroLogic

HydroLogic micro75 User manual

HydroLogic stealthro300 User manual

HydroLogic

HydroLogic stealthro300 User manual

HydroLogic EvolutionRo User manual

HydroLogic

HydroLogic EvolutionRo User manual

HydroLogic Merlin Garden pro User manual

HydroLogic

HydroLogic Merlin Garden pro User manual

HydroLogic Hydroid User manual

HydroLogic

HydroLogic Hydroid User manual

Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

Atlantic Ultraviolet

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun CBG-500 Operation manual

SunSun

SunSun CBG-500 Operation manual

Hayward XStream Filtration Series owner's manual

Hayward

Hayward XStream Filtration Series owner's manual

Contech DownSpout StormFilter Operation and maintenance

Contech

Contech DownSpout StormFilter Operation and maintenance

Teka Airfilter MINI operating instructions

Teka

Teka Airfilter MINI operating instructions

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Remove the outermost back screws on the
left and right side of the bracket and use
these to install the 2 membrane clips (A),
as shown in picture.
Push the Reverse Osmosis Membrane
Housing Assembly (B) onto the clips with
the cap side towards the right “inlet” side
of the unit.
Congratulations! Your system is now a 150
gallon per day Reverse Osmosis unit. Flush the
initial hour of product water down the drain.
You are now ready to use the system! Consult
the Stealth-RO150 manual from this point
forward. Contact us for help if needed.
7
5
3
2
Begin by turning off the water to the
unit, then remove the white ltered
water tubing from the “output” tting on
the system.
This kit allows you to upgrade your TALLBoy to a 100 gallon per day Reverse Osmosis unit.
Push the Elbow Stem Fitting at the end
of the white tube into the “output” tting
of the system.
Cut about 2" of the white “inlet” tubing to
install the Pressure Gauge Assembly (E) onto
the system. Push the remaining white “inlet”
tubing into the open tting on the Pressure
Gauge Assembly (E).
1
4
6
Instructions For: to Conversion Kit
Install the supplied blue ltered water tubing
to the open blue tting on the ASOV (C),
{Refer to the Quick Start Guide Instructions
for the Flow Restrictor/Flush Kit Assembly
(F) to select your preferred waste to product
ratio} and insert the supplied black tubing
into the black tting on the ASOV (C).
INCLUDED
- (2) Membrane Clips (A)
- Membrane Housing Assembly (B)
- ASOV (Automatic Shut Off Valve) (C)
- Flow Restrictor (D)
- Pressure Gauge Assembly (E)
- Flow Restrictor Quick Start Guide (F)
- Membrane Wrench (G)
- 150 GPD Membrane (pre-installed)
- Stealth-RO150 Manual
- Tubing & Fittings
Elbow Stem Fitting
C
A
D
B
E
G
F
For troubleshooting or technical assistance:
888-426-5644
techsuppor[email protected]
Once the initial flush is complete turn
the blue valve to the closed position
(perpendicular to the tubing)
The blue valve should be in the
closed position for normal operation
2
1
3
4
ASOV
See page 6 in the user manual for more info
Product water
(blue)
Waste water
(black)
1
Your kit includes:
1) Blue valve
2) Flow restrictor/flush kit assembly
3) 2:1 flow restrictor (purple tubing)
4) 1:1 flow restrictor (red tubing)
See page 6 in the user manual for more
information on flow restrictors & ratios
Choose your flow restrictor to
determine your waste water to purified
water ratio
Install your flow restrictor of choice (in
either direction) into the flow
restrictor/flush kit assembly (push both
ends of flow restrictor all the way into
the open quick connect fittings)
Note: Tap water over 300 PPM
recommended to use purple 2:1 flow
restrictor
Push short piece of pre-installed
black tubing on the flow restrictor/
flush kit assembly into the black
quick connect fitting on the ASOV
(where “out” is imprinted on ASOV)
When first starting up the system,
make sure the blue valve is in the
open position (parallel with tubing)
for 2-3 minutes to flush carbon pre-
filter
installation video available at: http://www.hydrologicsystems.com/products/stealth-ro-150