Read & Plan
Read and follow the Important Safety Information provided in the Programming and
Operations Manual prior to installing the HydraSwing. Read and follow these installation
instructions and make sure to conform to site specications and all local and federal
regulations and codes.
30⅝” (78 cm)
HydraSwing: Plan Site Design
1
2Measure and Calculate
Pay attention to gate swing (retracted or extended
cylinder) and clearance around the mounting location.
Consider right handing and left handing. Allow for
access to brake valves.
Use the charts, provided on pages 3 and 4, to
determine gate geometry and placement of the chassis
and gate mount.
HydraSupply
Reector
Key or card reader
Mount access control
devices at least 6 ft (183 cm)
beyond gate.
Pedestrian gate
HydraSwing
Warning Signs
Shadow Loop
Inside Obstruction Loop
or Free Exit
Outside
Obstruction
Loop
3Design Vehicle Loops
If automatic close is desired for a uni- or bi-directional
gate, a SHADOW and one other loop (IOLD or OOLD) is required.
Three loops are preferred: SHADOW, IOLD, OOLD (Free Exit, optional)
NOTE: Loop layout is dependent on uni- or bi-directional trafc and length of gate and width
of roadway. Vehicle must move from one loop to the next without loss of detection. The site
design shown on this page is for illustrative purposes only.
NOTE: Pay attention to
and plan for clearance
and access.
4Install conduit for communication and power
Locate and install the HydraSupply within 50 feet (6.1 m) of the HydraSwing gate operator.
NOTE: Order hose through HySecurity. See CAUTION.
Hose length in feet
(Total Run) Hose Diameter: Model 40 & 40F, Twin Hose Diameter: Model 80F & Model 150
0 to 50 ft 1/4 inch 3/8 inch
50 to 100 ft 3/8 inch 1/2 inch*
Minimum conduit required No. Min. Size cm
3/8 inch Hydraulic hoses* 1 2 inch 5
1/2 inch Hydraulic hoses* 1 3 inch 7.6
Sensor wire to operator 1 3/4 inch 2
AC Main power 1 1 inch 2.5
Conduit
Addt’l conduit may be ordered and used for: No. Min. Size cm
Bi-parting gate connection for low voltage wiring 1 1 inch 2.5
Heater or Emergency Release options 2 3/4 inch 2
HydraSupply Cabinet
Concrete pad
Shown
Post-mounted.
Roadway
Gate
Secure base plate with anchor
bolts. See NOTE regarding
bolt sizes on page 3.
HydraSwing 80F & 150 chassis
dimensions: 41”L x 20½” W
(104 x 52 cm) optional base
extension adds an additional
4” to the width
HydraSwing 40 & 40F chassis
dimensions: 27” L x 13” W
(69 x 33 cm)
Conduit runs between HydraSwing and cabinet.
NOTE: Design shown for illustrative purposes only.
Drawings are NOT TO SCALE.
Be sure to place the WARNING signs on the gate. For your
records, take a photograph of the completed installation site.
Wall
36” (91 cm)
minimum
36” (91 cm)
Door swing
Photo eye
Left handing
Right handing
12⅝”
(32 cm)
42⅜”
(107 cm)
HydraSupply
Cabinet
*NOTE: HydraSwing orders include two (2) uid-charged hoses and attached ttings totaling up to 50 ft (15 m).
Additional hose is billed by the foot. For HydraSwing 80F and 150, use 1/2-inch hose and ttings where the
HydraSupply cabinet is installed more than 50 ft from the actuator AND temperatures routinely fall below 0°F.
For distances between the HydraSupply and actuator longer than 100 ft (30 m), contact Tech Support.
HydraSwing
Left
handing
Incoming power
HydraSupply Cabinet
Inches: 30⅝W x 42⅜H x 12⅝D
Centimeters: 78W x 107H x 32D
Additional Hose
estimate
HydraSwing
Right
handing
HydraSupply
HydraSwing Bi-parting Gate
Maximum 50 foot run (15 m). See Hose Diameter chart above.
12 inches
(30 cm)
minimum
clearance from
grade
HydraSupply Cabinet
Wall or post-mount the
HydraSupply cabinet.
If planning a post mount, mounting
holes need to be drilled (U-bolts,
fasteners, and unistrut are not
provided). Cabinet may also be wall-
mounted with anchor bolts.
NOTE: The mounting holes on the
top and bottom anges are 5/16-
inch diameter.
13½”
(34 cm)
1⅞”
(5 cm)
1¼”
(3 cm)
Door clip
C/LC/L
Flange
Flange Unistrut U-bolt
30¾” (78 cm)
CAUTION
Remember to order hose through HySecurity!
In addition to conduit length, make sure
to measure hose requirements inside the
HydraSwing and HydraSupply. For example,
HydraSwing 80F requires about 1 ft of
additional hose length inside the operator
and another 2 or 3 ft inside the HydraSupply.
For proper sequencing of bi-parting (dual) gate systems, it is critical that the hydraulic
cylinder be fully extended. See “Determine Arm Geometry: 40 & 40F” on page 4.
CAUTION