temperature
compensation
(A1)
Range:-9°C~9°C,increment:0.5°C.
Because of install place and air convection factor in room,it need to calibrate or compensate current
room temperature for the system,making the test temperature conformity with the actuator temperature
Start
differential
temperature
(A2)
Range:1°C~5°C:
1、When the setting temperature is higher than or equal to the sum of indoor temperature and the start
differential temperature, the heating equipment will turn on.
2、When the indoor temperature is higher than or equal to the sum of the setting temperature and the
start differential temperature, the heating equipment will turn off.
0 half locked:all keys are locked except for the on-off key;
1 full locked。all keys are locked including the on-off key。
Sensor choice
(A4)
N1:single build-in sensor;
N2:single build-out sensor;
N3:build-in and build-out sensor。
high
temperature
protection(A5)
Range:35~70 When the lowest setting temperature is 35°C,press “ ”,it will display “ ”, high
temperature protection function is canceled; if the indoor temperature is higher than the high
temperature protection value,the heating equipment will be cut off. Default value is =45°C
low
temperature
protection(A6)
Range:5°C~10°C ;When the highest setting temperature is 10°C,press “ ”,it will display “ ”,
low temperature protection function is canceled; if the indoor temperature is lower than the low
temperature protection value,the heating equipment will be cut off. Default value is =5°C
setting
temperature
lowest limiting
value(A7)
Range:1°C~10°C:
setting
temperature
highest limiting
value(A8)
Range:30°C~70°C
Week
programme
choice(A9)
: represent 7days programme
:represent6+1 programme
:represent5+2 programme
“ ”represent programme is canceled
MODE 2:
At power off state, hold down “ and “ ”at the same time for 3 seconds it will display B1-B3,then
press “ ” to switch between these options