I-care HOME2 User manual

EN Quick Guide
ES Guía rápida
FR Guide rapide
AR
HE
Quick Guide
iCare HOME2
Quick Guide
iCare HOME2

If you need help in using the iCare HOME2
tonometer, contact your healthcare
professional.
For safety information, read Chapter 1 in
the Instruction Manual before using the
tonometer.
PRECAUTION! Before taking measurements,
update the tonometer’s time to your
local time manually from the tonometer’s
settings or automatically by connecting
the tonometer to the iCare PATIENT2
application or to the iCare EXPORT
software.
Read this Quick Guide and watch
the HOME2 user instructions video
before using the tonometer. Follow
the instructions step by step.

1 Inserting the batteries 5
2 Inserting the probe 6
3 Switching on 8
4 Correct measurement position 9
5 Adjusting the supports and positioning the tonometer 10
6 Measuring eye pressure 12
7 Measuring eye pressure in the supine position 14
8 Troubleshooting 16
9 Switching o the tonometer and disposing of the probe 18
Step Page
English

4
1Probe
2Probe base
3Cheek support
4Forehead support
5Measure button
6Select button
7Display
8Battery cover
9Wrist strap
10 Probe applicator
11 Screwdriver
Tonometer parts used during measurement
42
1
7
3
5
6
11
10
98

5
Inserting the batteries
1
Open the battery
cover with the
screwdriver.
Insert the batteries, and close
the cover.
The batteries are in the tonometer carrying
case under the box of probes.
AA/LR6
AA/LR6
AA/LR6
AA/LR6

6
Inserting the probe
2
Place the probe
applicator over the
probe base.
Open the
packaging.
Remove the cap.
WARNING! To prevent contamination, keep unused probes in
their box. Do not touch a bare probe. Do not use a probe if it
touches a non-sterile surface such as a table or a floor.
Do not use a
probe if it has
touched your
hand, a table, or
other nonsterile
surface.

7
Drop the probe
from the
container to the
probe applicator.
Remove the probe applicator.

8
3Switching on
Press down
until you hear a
beep. The text
“Start” is shown
on the display.
Alternatively, press down until you
hear a beep. Then press again to
enter the measurement mode. The text
“Start” is shown on the display.
3s
3s
OR

9
Correct measurement position
4
Positioning the tonometer is instructed in the
following section.
Look straight ahead and the
tonometer is at a 90-degree
angle to your face. The probe is
about 5 mm from your eye and
points perpendicularly to the
center of your eye.
The forehead
support A rests
on your forehead
and the cheek
support B rests
on your cheek.
If you see a red light in the probe
base, the tonometer is tilted too
much downwards. You should
straighten your posture and lift
your chin.
START
<90°
START 90°

10
5Adjusting the supports and positioning the tonometer
START
WARNING! Only the probe should touch the eye. Do not touch your eye with any
other parts of the tonometer. Do not poke your eye with the tonometer.
Place the tonometer against your face and
look into the probe base. The probe points
perpendicularly to the center of your eye
when the blue and green rings in the probe
base are symmetrical.
Before the measurement,
adjust the forehead and
cheek supports to the
correct length. Start
with the supports at the
maximum length.
Shorten the supports
only two clicks at a
time to prevent the
tonometer from getting
too close to your eye.

11
START
START
5 mm
Keep both eyes
open. Covering
the eye not being
tested may help
you see the rings
more clearly.
Shorten the supports by rotating them
clockwise two clicks at a time until you only
see a symmetrical green ring. The tonometer is
now at the correct distance from your eye.
If the rings are not symmetrical,
the probe does not point
perpendicularly to the center of
your eye. Correct the position of
the tonometer.

12
6Measuring eye pressure
Start the measurement
when you see only a
symmetrical green ring.
Press the Measure button
once. The probe gently
touches your eye.
If the probe base ashes
red and you hear multiple
beeps, the measurement
was not successful. See
Troubleshooting on page 16.
A single beep indicates a
successful measurement.
Continue taking measure-
ments until you hear a
long beep and the light in
the probe base turns o.
1x
START

13
6x
A measurement sequence consists of
six measurements.
Tip: You can also take the measurement
sequence by pressing and holding the
Measure button down until all six
measurements have been taken.
When all six
measurements have
been successfully taken,
you hear a longer beep,
the light in the probe
base turns o, and you
see the result on the
display.
Press the Measure button
once and repeat the
measurement on your
other eye.
START

14
7Measuring eye pressure in the supine position
Before measuring, lie down
for a moment.
Avoid bending your head
backwards.
Take a comfortable position
on your back with a pillow
behind your neck. Look
straight ahead.

15
Place the
tonometer at a 90
degrees angle on
your face and take
the measurement
as previously
instructed.
After a successful
measurement, press
the Measure button
once and repeat the
measurement on your
other eye.
START

16
8Troubleshooting
If an error occurs, the probe base ashes red. The
display and sounds indicate the source of the error.
Look at the display, press the Measure button
once, make the necessary corrections, and repeat
the measurement.

17
va u
Icon Display text Sound Problem Solution
TOO FAR
TOO NEAR
INCORRECT
ALIGNMENT
REPEAT
The probe is too far away from the
eye.
The probe is too close to the eye.
The probe was not perpendicular
to the cornea or the probe hit an
eyelid or eyelashes.
There was a problem with the
movement of the probe.
Press the Measure button once to acknowledge the
error. Shorten the forehead and cheek supports.
Press the Measure button once to acknowledge the
error. Lengthen the forehead and cheek supports.
Press the Measure button once to acknowledge the
error. Position the tonometer so that the probe points
perpendicularly to the center of your eye. Keep your eye
properly open.
Press the Measure button once to acknowledge the
error. Repeat the measurement.
3 long
5 short
2 short
2 short

18
9Switching o the tonometer and disposing of the probe
Dispose of the probe
and the container in
a mixed waste bin.
Press and hold
the Select button
until you hear
3 beeps and the
display switches o.
Remove the probe
and place it back
into the probe
container.
3s

19
Now you can transfer your measurement
results to your doctor’s iCare CLINIC or to your
private account in the iCare Cloud by using the
iCare PATIENT2 app on your mobile device or
the iCare EXPORT software on your computer.
START

Si necesita ayuda para utilizar el tonómetro iCare
HOME2, póngase en contacto con su profesional
de la salud.
Para obtener información sobre la seguridad, lea
el capítulo 1 del Manual de instrucciones antes de
utilizar el tonómetro.
¡PRECAUCIÓN! Antes de tomar mediciones,
actualice la hora del tonómetro a su hora
local manualmente desde la configuración
del tonómetro o automáticamente conectando el
tonómetro a la aplicación iCare PATIENT2
o al software iCare EXPORT.
Lea esta Guía rápida y mire el vídeo
de instrucciones para el usuario de HOME2
antes de utilizar el tonómetro. Siga las
instrucciones paso a paso.
Other manuals for HOME2
7
Table of contents
Languages:
Other I-care Personal Care Product manuals