Table 1. Features and specifications
Microprocessor:
vAMD Opteron
™
processor
v1MB Level-2 cache
Note: Use the Configuration/Setup
Utility program to determine the type
and speed of the microprocessors.
Memory:
vMinimum: 1024 MB
vMaximum: 16 GB
vType: PC3200 error correcting
code (ECC), double-data rate
(DDR) SDRAM, registered DIMMs
with Chipkill
™
memory protection
vSizes: 512 MB, 1GB, or 2GB
DIMMS in pairs
vFour interleaved slots with
standard microprocessor
vFour additional interleaved slots
with optional microprocessor
Drives:
vCD: Slim IDE (standard only on
some models)
vHard disk drives:
–Slim-high 3.5-inch drives,
hot-swap SCSI or
non-hot-swap Serial ATA
(SATA) (drive capacity and
speed vary with model)
–Maximum: Two
Expansion slots:
vTwo, used in either of the
following configurations:
–One 133 MHz/64-bit PCI-X
(full-length) and one PCI
Express x8 (half-length)
–One PCI Express x8
(half-length) and one PCI
Express x8 (full length) with
purchase of PCI Express x8
riser card
v
Supports 3.3 Vor universal
adapters only
Video controller:
vATI RN50b video controller on
system board
vCompatible with SVGA
v16 MB DDR1 video memory
Power supply:
One 411 watt (115-230 Vac)
Size:
vHeight: 43 mm (1.69 in.)
vDepth: 660 mm (25.98 in.)
vWidth: 440 mm (17.32 in.)
vWeight: approximately 12.7 kg (28
lb) when fully configured
Integrated functions:
vBaseboard management controller
vOne single-channel LSI Ultra320
SCSI controller
vTwo Broadcom 10/100/1000
Ethernet controllers (dual-port
design) with Wake on LAN
®
support
vFour Universal Serial Bus (USB)
ports
vOne serial port
vOne video port
Note: The baseboard management
controller is also known as the
service processor.
Acoustical noise emissions:
vDeclared sound power, idling: 6.5
bels
vDeclared sound power, operating:
6.5 bels
Environment:
vAir temperature:
–Server on: 10°to 35°C (50.0° to
95.0°F). Altitude: 0to 914 m
(2998.7 ft)
–Server on: 10° to 32°C (50.0° to
89.6°F). Altitude: 914 m(2998.7
ft) to 2133 m(6998.0 ft)
–Server off: 10° to 43°C (50.0° to
109.4°F). Maximum altitude:
2133 m(6998.0 ft)
v
Humidity:
–Server on: 8% to 80%
–Server off: 8% to 80%
v
Airflow rates:
–Minimum: 28 CFM
–Maximum: 47 CFM
Heat output:
Approximate heat output in British
thermal units (Btu) per hour for dual
multiprocessor configurations:
vMinimum configuration: 409 Btu (120
watts)
vMaximum configuration: 1366 Btu
(400 watts)
Electrical input:
vSine-wave input (50-60 Hz) required
vInput voltage low range:
–Minimum: 100 Vac
–Maximum: 127 Vac
v
Input voltage high range:
–Minimum: 200 Vac
–Maximum: 240 Vac
v
Input kilovolt-amperes (kVA),
approximately:
–Minimum: 0.120 kVA
–Maximum: 0.400 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and
type of optional features installed
and the power-management optional
features in use.
2. These levels were measured in
controlled acoustical environments
according to the procedures
specified by the American National
Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in agiven
location might exceed the average
values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which alarge number of computers
will operate.
Chapter 1. Introduction 5