Icom IP1000C User manual

IP1000C
PRECAUTIONS
IP ADVANCED RADIO SYSTEM
CONTROLLER Thank you for choosing this Icom product.
READ ALL INSTRUCTIONS carefully and completely
before using this product.
–1 –
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
May 2022
–4 –
LAll stated specications and design are subject to change without notice or obligation.
Icom and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United
Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries.
All other products or brands are registered trademarks or trademarks of their respective holders.
A7125W-1EX-2 Printed in Japan
© 2014–2022 Icom Inc.
Important
SAVE THESE INSTRUCTIONS— These instructions
contain basic (important) operating instructions for the
IP1000C.
Explicit Denitions
WORD DEFINITION
RWARNING! Personal injury, re hazard or electric
shock may occur.
CAUTION Equipment damage may occur.
NOTE
If disregarded, inconvenience only. No
risk of personal injury, re or electric
shock.
Icom is not responsible for the destruction, damage
to, or performance of any Icom or non-Icom
equipment, if the malfunction is because of:
• Force majeure, including, but not limited to, res,
earthquakes, storms, oods, lightning, other natural
disasters, disturbances, riots, war, or radioactive
contamination.
• The use of Icom product with any equipment that is
not manufactured or approved by Icom.
FCC Information
CAUTION: Any changes or modications not
expressly approved by the party responsible for
compliance could void the user’s authority to operate
the equipment.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Below statement is for UKCA purpose only
United Kingdom Authorised Importer: Icom (UK) Ltd.
Address: Blacksole House, Altira Park, Herne Bay, Kent,
CT6 6GZ, U.K.
The automatic rmware update for the WLAN transceivers
The IP1000C has an “Automatic Firmware Update at Power ON” function that allows the WLAN transceiver to
check the rmware version at booting and automatically update if new rmware is available.
• You can enable this function in Transceiver Settings > Transceiver Settings > Maintenance of the IP1000C
setting screen.
• The WLAN transceiver checks for a rmware update while booting. If available, it automatically updates and
then restarts with new rmware.
About CE
Versions of the IP1000C which display the “CE”
symbol on the serial number label comply with
the essential requirements of the 2014/30/EU
directive for Electromagnetic Compatibility and the 2001/95/
EC directive for General Product Safety.
Disposal
The crossed-out wheeled-bin symbol on your
product, literature, or packaging reminds you
that in the European Union, all electrical and
electronic products, batteries, and
accumulators (rechargeable batteries) must be
taken to designated collection locations at the
end of their working life. Do not dispose of these products
as unsorted municipal waste. Dispose of them according to
the laws in your area.

–3 –– 2 –
DFor the power adapter
RWARNING! NEVER use the power adapter with
any device other than the IP1000C. This may result in
an electrical shock, cause a re or damage the power
adapter.
RWARNING! CONNECT the adapter into an outlet
between 100 V and 240 V AC. Otherwise, this may
result in an electrical shock, cause a re or damage
the power adapter.
RWARNING! NEVER install the power adapter to
wet place outside or near a humidier. This may
result in an electrical shock, cause a re or damage
the power adapter.
RWARNING! NEVER put something heavy on the
power adapter cable. This may result in an electrical
shock, cause a re or damage the power adapter.
RWARNING! NEVER modify, bend by force, twist,
pull or heat the power adapter’s cable. This may result
in an electrical shock, cause a re or damage the
power adapter.
RWARNING! NEVER touch the power adapter with
wet hands. This may result in an electrical shock or
damage the power adapter.
RWARNING! Use and place the power adapter and
connection cable to avoid inadvertent use by children.
This may result in an electrical shock or cause injury.
DOther precautions
• For information about operating the PC or external
devices, refer to their instruction manuals for
details.
• The supplied power adapter may at some
time need to be replaced, depending on its life
expectancy. The life of a power adapter differs
according to the environment or condition in which
the adapter is used.
We recommend replacement when it has been
used for approximately 5 years (When used under
the ambient temperature of 25°C; 77°F). Contact
your local dealer for details.
Precautions
DFor the IP1000C
RWARNING! NEVER use other than the supplied
power adapter. This may result in an electrical shock,
cause a re or damage the IP1000C.
RWARNING! NEVER attempt to connect the power
adapter to other than the [DC] jack on the IP1000C
rear panel. This may result in an electrical shock,
cause a re or damage the IP1000C.
RWARNING! NEVER disassemble, modify or repair
the IP1000C. This may result in an electrical shock,
cause a re or damage the IP1000C.
RWARNING! NEVER install the IP1000C in a wet
place or outside. This may result in an electrical
shock, cause a re or damage the IP1000C.
RWARNING! NEVER operate or touch the IP1000C
with wet hands. This may result in an electrical shock
or damage the IP1000C.
RWARNING! NEVER connect the ground terminal to
a gas or electric pipe. This may result in an electrical
shock or cause a re.
RWARNING! NEVER use the IP1000C during a
lightning storm. It may result in an electric shock,
cause a re or damage the IP1000C. Always
disconnect the power adapter before a storm.
RWARNING! Immediately disconnect the power
adapter if the IP1000C emits an abnormal odor, sound
or smoke. Contact your Icom dealer or distributor for
advice.
RWARNING! NEVER put the IP1000C in any
unstable place (such as on a slanted surface or
vibrating place). This may cause injury and/or damage
to the IP1000C.
CAUTION: NEVER install the IP1000C in a place
without air vents. Heat dissipation may be reduced,
and this could damage the IP1000C.
CAUTION: DO NOT use or place the IP1000C in
areas with temperatures below 0°C (+32°F) or above
+40°C (+104°F).
CAUTION: DO NOT place the IP1000C in direct
sunlight. This could damage the IP1000C.
CAUTION: DO NOT use the IP1000C in strong
magnetic elds or in an area with high static electricity.
This could damage the IP1000C.
CAUTION: Disconnect the power adapter when you
will not use the IP1000C for a long period of time.
CAUTION: DO NOT use harsh solvents such as
Benzine or alcohol when cleaning, because they will
damage the IP1000C’s surfaces.
Always place the IP1000C in a secure place to avoid
inadvertent contact with unauthorized persons.
Initializing the IP1000C
If you cannot access the IP1000C setting screen, you can initialize (reset) the IP1000C by pushing [INIT] on the
rear panel.
• This initializing resets all settings to the factory defaults.
• See the IP1000C instruction manual for initializing from the setting screen.
LIndications other than the specied below may differ, depending on the network environment.
1. Disconnect all cables from the IP1000C, and then
connect the power adapter.
LVerify that the [PWR] indicator lights green.
2. Push in and hold [INIT] on the rear panel with
a pin until all indicators on the front panel light
orange, and then release.
• The initialization starts.
• When the initialization has been completed, [PWR]
lights green.
:Black out
<Status>
[LED indication]
[Operation]
:Light :Blink
Turn ON the IP1000C
Use
a pin
Power
adapter
後面部
Rear
panel
[INIT]
Push in and hold
Release
Lights
(Green)
Lights
(Green)
Blinks
(Orange)
Lights
(Orange)
Blinks
(Orange/Green)
Blinks
(Green)
All LEDs light (Orange)
Lights
(Green)
The rmware update function
The [MSG] LED lights green when an IP1000C rmware update is available.
To use the Firmware Update function, an internet
connection, the DNS and default gateway must be set.
See the IP1000C instruction manual for the setting
details, or contact your Icom dealer or distributor for
advice.
NOTE: NEVER turn OFF the IP1000C until an
update has completed. Otherwise, the IP1000C
rmware may be damaged.
DUpdating the rmware
If a rmware update is available, the [MSG] lights
green. Follow the procedures below to download and
install the new rmware.
zPush in and hold [UPDATE] on the front panel with
a pin until [MSG] blinks, and then release.
• The IP1000C automatically starts download and
updates the rmware, and then reboots.
NOTE: The IP1000C may automatically update the
rmware without any indication and reboot even
while in use, depending on the updated content.
Disable the automatic update function if you do not
want the IP1000C automatic updates.
Use a pin
Push in
and hold
Front
panel
Release
:Black out
<Status>
[LED indication*]
[Operation]
:Light :Blink
After the rebooting,
[PWR] lights green.
Lights
(Green)
Blinks
(Green)
All LEDs light (Orange)
LIndications other than [PWR] and [MSG] may differ, depending on
the network environment (Except for when all LEDs light.)
Other manuals for IP1000C
3
Other Icom Controllers manuals