0
ICOM
CS-207
OPERATING GUIDE (for IC-207H)
GETTING STARTED
I
p
Before using the program, make a backup copy of To use this program, the following hardware and
the original disk. Operate the program using the
#
ba software are required:
A
ckup
and keep the original in a safe p/ace. l IBM PC/AT or
PS/2
compatible computer with an
RS-232C serial port
This cloning program is designed to perform data
setting and cloning for the dual band transceiver
IC-207H.
l MS-DOS, PC-DOS or IBM DOS ver. 5.02 or higher
. OPC-646 CLONING CABLE
I
CONNECTIONS
I
cloning operations are performed from
computer’s keyboard including power ON
-
only connect to a DC power supply is needed
r
the transceiver.
DB9
female plug
IC-207H
(incl.
level converter circuit)
\
Personal
computer
-646
Cloning cable
be purchased separately)
INSTALLATION AND PROGRAM START UP
n
Installation and initial setup’
Connect the transceiver and PC as above then con-
nect a DC power supply to the the transceiver.
To install the CS-207 cloning software to
ICOM\CS207
directory of drive C while the program
disk is in drive A, type as follows at the DOS prompt:
A:\INSTALL A:
C:\ICOM\CS207
[Enter]
T
I
Program drive
‘7”
Target drive/directory
A target directory is created if it does
not
already
exist; CS-207 cannot be installed to the root directory.
After the installation is finished, the CS-207 initial
setup screen appears and the transceiver model is
checked. Proceed as follows:
0
Select the connected RS-232C
(COMlKOM2)
port with the [
t]/[
$1
and [Enter] keys.
@
Input your call sign then push [Enter].
@
After the initial setup, CS-207 is automatically
launched. Set or modify the data as desired.
l See the back page for operation.
@>‘fie
the File sub menu to save the data or to exit
the program.
To start the program after installation, operate as
n
Starting the program
follows at the DOS prompt:
@)
Change to the installed directory.
l
C:\ICOM\CS207
in case of the example at left.
@
Type as follows to start:
CS207
[Enter] (at the installed directory)
n
Operating from a floppy disk
This program can be operated from a floppy disk.
0
Insert the backup disk into the floppy disk drive.
@
Select the floppy disk drive as the current drive.
@
Select the
“CS207”
directory.
@
Type
“CS207,”
then push [Enter] to start.
1
floppy
disk.
NEVER remove the program disk from the floppy disk
drive while the
7
program is running.
NEVER set the floppy disk as write-protected.
Cloning will take 20 sec. or more when operating from a
Portions of this software are copyrighted by Microsoft Corporation.
MS-DOS is a Microsoft trademark.
I”,,
m-,.-F
m-.-
-- --- ,.-..---
.~