iNels Elco AirSOU-100NB User manual

1 / 3
+
-
AirSOU-100NB
02-26/2018 Rev.: 0
1
4
5
8
5
3
7
2
9
10
6
21
5
Click!
3a
4
+
-
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: [email protected]
www.elkoep.com
Characteristics
EN
Twilight sensor
Made in Czech Republic
• Information about the actual light intensity can be used in the task of maintain-
ing a constant illumination in a given space, where it is possible to regulate the
intensity of articial lighting thanks to the contribution of natural lighting from
outside, thereby reducing the energy consumption.
• AirSOU-100 can be used not only in residential projects, but also in commercial
oce projects or production and warehouse or production halls.
• The AirSOU-100 is recommended to be installed so that the light sensing sensor is
facing downwards and not exposed to direct light.
• The scanning range is 1 - 100,000 lux.
• Data is sent to the server from which it can be subsequently displayed as a smart-
phone, application, or Cloud notication.
• Battery power can be sent to the server when it is powered by a battery.
• The AirSOU-100 is supplied in an IP65 enclosure and can be installed in an out-
door environment.
Device description
1. Tamper
2. NanoSIM slot
3. Programming pins
4. Button SET
5. Mounting hole Ø 4.3mm wall
6. Sensing sensor
7. Light guide
8. Antenna
9. Battery
10. LED
Cloud app assignment
It is done in your Smartphone application. Enter the relevant information on the product
cover into the application.
Function
After inserting the batteries, the sensor sends an introductory message containing the
measured light intensity.
The sensor scans the light intensity every 2 minutes. After that, it sends a data message
of measured values every 60 minutes. In the event of a sudden change in light intensity,
it sends the data message immediately.
General instrucions
Assembly
1. Using a at-blade screwdriver gradually slide it into one groove and the other in the lid
and swing open the cover.
2. Carefully insert nanoSIM (the device must not be energized when inserting or replacing
nanoSIM!)
3. The product can be attached in two ways:
a) Directly on a at surface by gluing * - apply a suitable adhesive to the bottom of the
base. Place the base in the desired location and let it dry.
b) Using a suitable fastener ** by screwing - drill holes into the base with two holes of
suitable diameter corresponding to the position of the holes in the bottom of the box.
Place the base at the desired location and attach it with suitable bonding material
according to the substrate.
4. Insert the battery into the sensor and check correct location (the sensor functionality
message is sent to the application when the battery are inserted).
5. Replace and snap the front cover. When closing, the handles have to be snapped to their
original position.
* The glue must meet the optimal conditions for product placement (inuence of tem-
perature, humidity ...)
** For example, a screw or screw of max. Ø 4 mm can be used as a suitable fastener mate-
rial, 13 mm (distance to the partition in the box) must be added to the required length
for attachment to the substrate.
Internet of Things (IoT)
• The IOT wireless communications category describes the Low Power Wide Area
(LPWA). This technology is designed to provide full-range coverage both inside and
outside buildings, energy-saving and low-cost operation of individual devices. The
NarrowBand network is available to use this standard.
Information about the NarrowBand network
• The network provides two-way communication and the only one to use the licensed
LTE band. Our devices allow band 1 (2100MHz), Band 3 (1800MHz), Band 8 (900MHz),
Band 5 (850MHz), Band 20 (800MHz) and Band 28 (700MHz).
• It uses this SIM card technology for each device.
• The advantage of NarrowBand is the use of already built-up grids, which ensures suf-
cient reception outside and inside buildings.
• For more information on this technology, please visit www.vodafone.cz
Caution for proper operation:
• Products are installed according to the wiring diagram given for each product.
• For proper device functionality, it is necessary to have sucient coverage of the se-
lected network at the installation site.
• At the same time, the device must be registered in the network. Successful device reg-
istration on a given network requires a charge for trac.
• Each network oers dierent tari options - it always depends on the number of mes-
sages you want to send from your device. Information on these taris can be found in
the current version of the ELKO EP pricelist.

2 / 3
1 3
Click!
2
+
-
Placement recommendations
• For the correct operation of the sensor, it is necessary to eliminate all disturbing light
sources in the sensed area.
• Before mounting, check the range and location of the product and the antenna. Ensure
the correct location - see Warning.
• The sensor is suitable for outdoor use. Operating conditions are consistent with con-
ventional chemically non-aggressive environments.
• The recommended working position is vertical; the light guide should point down-
wards or upwards.
• For proper functionality, the light guide should be kept clean and uncovered (occasio-
nal cleaning of the light pipe without the use of chemicals).
Inappropriate location
• Places where distortion may occur (the light pipe must not be illuminated by direct
light) - below the lamp, where there is a sudden change in lighting intensity (e.g. a-
shing advertising), etc.
• Very dusty environment.
• In the case of a light guide installation, the light guide should not be exposed to wea-
thering (sensing distortion may occur due to rain / snow).
When handling a device unboxed it is important to avoid contact with
liquids. avoid unnecessary contact with the components of the device. Do
not touch the metal objects inside the unit.
Safe handling
Restart
• Open the cover. Power interruption (remove the battery from the device).
• Press SET> 1min.
• Connect power (insert battery). Close the cover.
Replacing batteries
1. Using a at-blade screwdriver gradually slide it into one and then the other groove in
the lid and swing open the cover.
2. Remove the discharged battery and insert a new battery into the holder. Beware of
polarity. Both LEDs will ash 3 times (see device status indication).
3. Replace and snap the front cover.
Notice:
Only use batteries designed for this product correctly inserted in the device! Immediately replace
weak batteries with new ones. Do not use new and used batteries together. If necessary, clean the
battery and contacts prior to using. Avoid battery shorts! Do not dispose of batteries in water or
re. Do not dismantle batteries, do not try to charge them and protect them from extreme heating
- danger of leakage! Upon contact with acid, immediately rinse the aected area with a stream of
water and seek medical attention. Keep batteries out of the reach of children. If it is suspected that
the battery has been swallowed or somehow placed inside the body, consult a doctor immediately.
Give the doctor information about the type of battery (from battery case, device or its manual, etc.)
to determine the chemical composition of the battery. Batteries must be recycled or returned to an
appropriate location (e.g. collection container) in accordance with local legal provisions.
power supply (external or battery),
reset unit
Connection to the network
SIM Error - cannot be loaded (SIM
card insertion and rotation check) /
or NB-IoT MODULE error
start unit ok
opening the cover
test, cancel,„long press“
setting mode (signaling of meas-
urement)
light measurement
sending / receiving data
it is necessary to disconnect the power sup-
ply (external or battery), after 60 seconds
after the LED goes out, insert the battery
the battery may be discharged
a discharged battery or a damaged
product
Device states
Unit initialization
Start
Search for BTS *2)
SIM ERR *2)
ERR *2)
Successful network connection *2)
Measurement
Tamper
SET button short press (< 2s)
SET button longer press
(>2s / <5s)
Measurement signaling *1)
Communication
Communication
Other known states
Does not respond to the SET
button
The unit is still in reset
The unit does not respond even
after removal insert the battery
Indication
3 x R + G blinks
2 x ashes R (2xR _ 2xR _ ...)
5 x ashes R (repeatedly)
1 x ashes R
without indication
1 x ashes G
2 x ashes G
1 x ashes G
1 x ashes R
any LED lights
still indicates start
without indication
When the tamper is pressed, the LED is
turned o!
Note:
R... LED red
G... LED green
* 1) Indicates only when you press SET
> 2 s (setting mode)
* 2) Planned
UPLINK
Byte 0-14 15 16 17 18 19 20 21
Bit 765432 1 0
HEARTBEAT
IMEI
1 0x10 Reserved for future use
Tamper:
1 - opened
0 - closed
Battery:
1 - low level
0 - OK
Illuminance[0] Illuminance[1] Illumi-
nance[2]
Illumi-
nance[3]
START 3 Version
FW Subversion FW Version FW
Narrowband
Subversion FW
Narrowband
Name Unit Example
Illuminance[0 – 3] [100*] lx
Illuminance[0] = 0x00
Illuminance[1] = 0x00
Illuminance[2] = 0x07
Illuminance[3] = 0xD0
Illuminance = 0x000007D0
= 2000 / 100 = 20 lx

3 / 3
AirSOU-100NB
Technical parameters Warning
* Values are calculated under ideal conditions
** Depending on network coverage
*** Multiple frequency bands of B1 / B3 / B5 / B8 / B20 / B28
**** Without battery
Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualication upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you
notice any sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated. Before starting installation, make sure that all
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are energized – life
threat. To ensure the transmission of the radio signal, make sure that the devices in the
building where the installation is installed are correctly located. Unless otherwise stated,
the devices are not intended for installation in outdoor and damp areas, they must not
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby
disabling the remote control.
Photo sensor parameters
Light measurement range:
Detection angle:
Power supply
Battery power:
Battery life by frequency *:
1x 10 minutes
1x 60 minutes
1x 12 hours
1x 24 hours
External power supply:
Supply voltage tolerance:
Standby consumption:
Transmitting power consumption:
Setting
Setting:
Battery status view:
Control
Control:
Communication
Protocol:
Transmitter frequency:
Range in open space:
Transmission power (max.):
Other parameters
Working temperature:
Storage temperature:
Operation position:
Mounting:
Protection degree:
Dimension with antenna:
Weight:
1 - 100 000 lx
100°
1x 3.6V LS 14500 Li-SOCl2AA
1.9 years
3.2 years
3.6 years
3.6 years
5- 12 V DC (on terminal)
+10 %; -15%
0.2 mW
850 mW
Using a message from the server,
the programming cable
message to the server
button (Communication test)
Tamper
NB-IoT
LTE Cat NB1**
Approx. 30 km***
200 mW / 23 dBm
-30…+60°C (Pay attention to the operating
temperature of batteries)
-30…+70°C
vertical
glue / screws
IP65
158 x 62 x 34 mm
108 g****
The company ELKO EP, as the manufacturer, is entitled to make technical modications to the product, in the technical specication and product manual, without prior notication.
Other iNels Accessories manuals

iNels
iNels RFTI-20 User manual

iNels
iNels RFSC-61 User manual

iNels
iNels RFSC-61 User manual

iNels
iNels AirSOU-100L User manual

iNels
iNels RFSC-61N User manual

iNels
iNels RFSC-61 User manual

iNels
iNels RFSC-61 User manual

iNels
iNels RFTI-20 User manual

iNels
iNels RFDSC-71N User manual

iNels
iNels RFSC-61N User manual
Popular Accessories manuals by other brands

Notifier
Notifier FST-751 Installation and maintenance instructions

Eizo
Eizo UX2 Instructions for use

PCB Piezotronics
PCB Piezotronics 132B38 Installation and operating manual

DIEL
DIEL MT300 DIN Installation and instruction manual

Vega
Vega vegacap 62 operating instructions

embrava
embrava Desk Sign installation guide