Setting Setting Value Factory Description
Display Ranges Default
Settlnas
Opening speed OS 1 to 99 85 Controls the opening speed of the door. It is recommended that
the door be operated as slowly as practical for the traffic
conditions.
Autcrreverse opening AO 1 to 99 75 Controls the amount of force required to reverse the door when
ooaning (see FEATURES\.
Backcheck
DC
sition bP 1 to 32 08 Controls where backcheck nnsition starts.
Backcheck sneed bS 50 to 99 80 Controls the door soeed durinn backcheck.
Hold Open Delay
hd
1 to 32 01 Controls the amount of time the door stays open. If a presence
sensor is not installed, the time delav must be at least 4 seconds.
Closing speed CS 1 to 99 75 Controls the dosing speed of the door. It must not exceed 1
ftIsec.
Autcrreverse closing AC 1t099 50 Controls the amount of ~rce required to reverse the door when
closino (see FEATURES.
Latch position LP 1 to 32 07 Controls where latch position starts. It must be at least 2 inches
from the fullv closed IV\sition.
Latch soeed LS 50 to 99 85 Controls the door speed durina latch.
Energy-wise EP 50 to 75 50 Adjusts the open position of the door from 50% to 75% of full
aDen when enerav-wise switch is set to narrow.
Electric Lock EL ON or OF Enables (ON) or disables (OF) the electric lock delay. If EL is set
OF to OF, the door opens immediately upon reception of the
activation signal. If EL is set to ON, when the door is fully dosed,
there is a 1 second delay between reception of the activation
signal and the actual opening of the door. This delay allows most
electric or maanetic locks time to unlock before the door onens.
Sizinn saeed SS 50 to 99 85 Controls the sneed of door durirv;-sizina:
Function Fn 00 00 This seltin not used at this time.
Status Announcement SA 00 00 This seltinn not used at this time.
Reset Power:
If main power needs to be reset for any reason, power must remain off for a minimum of ten (10) seconds to allow proper discharge of internal
circuitry.
84657-084 REV. B July 2003 Page 5 of 7