Programming 19
Installation and programming manual
PHASE 2
Unenroll: LED DL3 will emit in series 2 blinks followed by a pause. LEDs DL1, DL4
and PRG will remain off.
Press the "ENROLL" button on the device you wish to unenroll (delete). Press
simultaneously keys F3 and F4 on the wireless keyfob. Within 4 seconds, LED DL2
should flash to indicate that the device has been received and unenrolled.
PHASE 3
Change transmission/reception channel: LED DL3 will emit in series 3 blinks
followed by a pause.
LED DL4 emits a number of blinks equal to the number of the current channel. 3
channels are available. Press button P2 to activate the successive channel to the
one currently operating on the Air2-BS200 module. At this point, press the
“ENROLL” button on all the detectors and sounders, access the “ENROLL” menu on
the Air keypad and press keys F3 and F4 simultaneously on all the keyfobs. This
will synchronize the system wireless devices with the new channel.
PHASE 4
Enable/Disable tamper Air2-BS200: LED DL3 will emit in series 4 blinks
followed by a pause.
LED DL4 indicates the status of this option: OFF = Tamper enabled; ON = Tamper
disabled. Press button P2 to toggle the status of this option. If the Tamper option
is disabled, the status of both microswitches will be ignored.
PHASE 5
Enable/Disable rolling-code authentication on Air2-KF100: LED DL3 will
emit in series 5 blinks followed by a pause.
LED DL4 indicates the status of this option: OFF = Rolling code authentication
enabled; ON = Rolling code authentication disabled. Press button P2 to toggle the
status of this option.
PHASE 6
Addressing: LED PRG will go On solid. LED DL1-4 indicates the current address.
Refer to paragraph 4-6 Addressing the Air2-BS200.
5-3Air2-BS200 module
default settings
To restore the factory default settings, press and hold the P2 button until the 4
LEDs (DL) come ON duringPhase 2 - Unenroll, as previously described.
5-4Options programmable
at the control panel
During the programming phase of the SmartLiving control panel you can set the
following options for the “wireless” zones:
Table 21: Wireless zones options
Option
If enabled If disabled
TampReed/FollPir
(Air2-IR100)
In order to increase battery life, the infrared
sensor will deactivate when the partitions it
belongs to are disarmed and will only activate
when the partitions it belongs to arm.
Disabled detectors cannot generate alarms. When
the partitions arm, there may be a delay of up to
3 minutes before the detector receives the
activation command.
The IR sensor is always active.
TampReed/FollPir
(Air2-MC100/MC200)
Tamper on the magnetic contact will be detected. Tamper on the magnetic
contact will not be detected.
Broadcast RF
This option must be enabled when the zone and
one of the Air2-MC100 terminals (“T1” or “T2”) is
configured as an “output”. Assures the activation/
deactivation of the output within two seconds of
the control panel command.
The activation/deactivation of
the “wireless” output occurs
within two minutes of the
command from the control
panel.
Use sensor LED
The red LED of Air2-IR100 and Air2-MC100/
MC200 devices signal alarm or tamper on the
device.
The red LED of Air2-IR100 and
Air2-MC100/MC200 devices is
always Off.
ATTENTION!
In the case of an Air2-MC100 device, this option should be enabled on
all its terminals.