4General information
Wireless accessories
Each SmartLiving control panel supports more than one Air2-BS100 module,
connected via I-BUS, in accordance with the contents of the table:
For optimal performance of the wireless system the Air2-BS100 transceiver
module must be located at the core of the wireless network devices and area of
use of remote-control keys, in a placement which allows easy connection of the I-
BUS cable to the control panel.
All wireless protection devices should be installed in elevated positions in order to
increase detection capabilities and prevent inadvertent blinding caused by large
objects or building occupants.
The signal strength (transmitted/received by the Air2-BS200 transceiver module)
of each wireless device can be viewed on the keypads and via SmartLeague
software, this information can be used to optimize the installation process.
Note
A level 3 signal strenght it is recommended for a good installation.
As an integral part of the system, the Air2 provides 3 inter-module transmission
channels. This feature allows you to select the channel in such way as to avoid
over-the-air interference between two close-proximity wireless systems (for
example, in two adjoining apartments).
For secure deployment and operations of the Air2 wireless intrusion protection
system, it is necessary to refer to the Installation and programming guide of the
hardwired intrusion control panel in use.
1-4Notes from the
Manufacturer
Note
The Air2-MC100 device is certified by IMQ-Sistemi di sicurezza (Italian
certification body).
The notified body N°0051, intervened in the R&TTE Directive conformity
assessment procedure for all the devices of the Air2 system, with the exception of
the Air2-FD100 and Air2-MC200.
The information relating to the power-supply batteries required by Air2 devices is
shown in the Technical Specification table that follows.
The manufacturer cannot guarantee the declared battery life.
ATTENTION!
Do not use batteries other than those indicated by the manufacturer as they may
explode.
Used batteries must be disposed in accordance with local regulations.
For the technical description and installation instructions of any Air2 devices not
described in this manual, refer to the respective manuals included in the
packaging of the various devices.
Table 2: Number of Air2-BS100 managed by the control panel
Control
panel FW SmartLiving control panel Notes
505 515 1050 10100
6.00
10 20 30 Does not manage Air2-
Aria and Air2-Hedera
6.01
10 20 30 Manages all Air2 devices