Innosonian BRAYDEN User manual

CPR Training Manikin
Instructions for Use
English

2
Getting started
Thank you for purchasing our product.
The purpose of CPR is to supply oxygen to the brain and heart of a casualty whose heart has stopped beating normally. Applying chest compressions correctly achieves this by causing blood
to ow, supplying oxygen to the brain and heart.
‘BRAYDEN’is the rst CPR training manikin in the world which has a blood circulation display – designed to help the student understand and remember the principles of CPR.
The product package includes the following components.
Main manikin unit (1)
Face skin (1)
Face shield (10)
Articial lung (1)
Instructions for use (1)
Mat bag (1)
Battery (6)
*For IM13 only
AC adapter (1)
*For IM13 only (Option)

3
English
Product name
①Normal circulation indication light
This illuminates to represent that blood is reaching the brain. When the depth and
speed of the compressions are correct, the light will illuminate. The brightness of the
light varies according to the depth of the compressions.
②Blood circulation indication lights
T
hese illuminate to represent the ow of blood from the heart to the brain. The speed
of the blood ow varies according to the depth and speed of the chest compressions.
③Compression depth indication lights
T
hese illuminate to represent the volume of blood being circulated by the chest
compressions. This volume depends upon the depth of the compressions – deeper
compressions illuminate the lights for a longer time, shallower compressions
illuminate the lights for shorter time.
④Power switch
T
his turns the manikin on and o.
⑤Power status indicator lamp
When the manikin is switched on, a green light indicates that it is operating normally,
a ashing red light indicates that the batteries are running low.
⑥AC adaptor connection
C
onnect the optional AC adapter here.
⑦Clicker On/O switch
A
‘clicker’which sounds with each compression over 5㎝in depth can be turned on or
o using this switch.
⑧Battery cover
Remove this to replace the batteries.
I O
2
3
1
8
4
56
7

4
How to use the manikin
▒Chest compression
xTurn on the manikin.
xEnsure that the power status indicator
lamp is illuminated green.
xBegin compressions. The ‘blood circulation’and ‘compression
depth’indication lights will illuminate according to the depth
and speed of compressions.
xWhen chest compressions with excessive depth of compression
(over 6cm) are performed, all of the ‘compression depth’
indication lights will illuminate. When chest compressions with a
fast speed (over 120 times per minute) are performed, all of the
‘blood circulation’indication lights will illuminate.
xWhen chest compressions with a depth of
compression between 5cm and 6cm and a speed
between 100 times and 120 times per minute are
performed, the ‘normal circulation’indication light
will illuminate.
For more details, refer to “Change the operation
method”.
▒Articial respiration
xOpen the face
shield.
xPlace the mouth part of
face shield on the mouth of
manikin.
xOpen the airway.
xHold the nose with your
thumb and index nger, and
blow air through the mouth
for 1 second.
xVisually check that the manikin
chest is rising.

5
English
▒Change the operation method ▒Change the clicker setting
< Basic operation > < Specialized operation > < ON > < OFF >
xWhen the manikin is turned on, the manikin always operates in <basic operation>, and
when chest compressions with a constant depth of compression over 3cm for 5 seconds
are performed, it will switch to <specialized operation>.
xThe ‘normal circulation’indication light will illuminate when chest compressions with
a depth of compression over 5cm and a speed between 100 times and 120 times per
minute in <basic operation> or chest compressions with a depth of compression
between 5cm and 6cm and a speed between 100 times and 120 times per minute in
<specialized operation> are performed.
xTurn the ‘clicker’on and o using the switch as shown. The clicker makes a “clicking“
sound when the chest is compressed more than 5cm.
▒Note
xWhen the manikin is turned on, a one-time automatic calibration will be carried out for approximately 2 seconds.
It is recommended that chest compressions on the manikin not be performed when automatic calibration is being carried out.
xIf the chest compression is not detected for 2 seconds, the blood circulation indication lights, the compression depth indication lights and the normal circulation indication light will
be turned o and the manikin will enter stand-by mode. When in stand-by mode, the power status indicator lamp will ash green.
xWhen the user carries out chest compressions again while the manikin is in stand-by mode, the chest compressions will be detected automatically and the indicators will operate
again. However, if left in stand-by mode for 30 minutes, the manikin will switch itself o to conserve the batteries. To switch the manikin on again, slide the power switch to the ‘o’
position for more than 2 seconds and then switch it on again.
xWhile in stand-by mode, the power consumption is very low. However, we recommend that you switch o the manikin when not in use.
xIf the battery is low, the power status indicator lamp will ash red. At this time, replace the battery with a new one.

6
Maintenance
▒Replacing the articial lung
12
1
2
1
2
1
2
3
▒Battery
xReplacement method Caution
xKeep the used batteries out of reach of children and dispose of safely.
xDo not use new batteries and old batteries together. When replacing them, replace all 6
batteries together.
xIf you do not use the manikin for a long period of time, remove and store the batteries.

7
English
Product and accessories
▒Product : CPR Training Manikin “BRAYDEN”
IM13
(Blood circulation display type)
IM13-S
(Simple type)
The IM13-S model does not include the blood circulation display function.
If you want the blood circulation display function, you need to purchase the
IM13 model.
▒Product specications (IM13)
Dimensions 32cm x 59cm x 21cm (W x H x D)
Weight 3.1Kg (6.8lb)
Operating temperature 0°C to 40°C (32°F to 104°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
HumidityRelative humidity between 5% and 95%
Power AC adaptor (Input AC 100–260V, Output DC 9V 1A)
Battery C type 1.5V (6 batteries)
▒Accessories
Face skin
IM13-SA01
Body skin
IM13-SA02
Head unit
IM13-SA03
Chin
IM13-SA04
Body
IM13-SA05
Rib
IM13-SA06
Face connection
IM13-SA07
Airway valve
IM13-SA08
Articial lung
IM13-SA09
Clicker
IM13-SA10
Clicker actuator
IM13-SA11
Spring
IM13-SA12
0DQXDO
Mat bag
IM13-SA13
Instruction for use
IM13-SA14
Face shield
IM13-SA15
AC adaptor
IM13-OA01

8
Quality assurance
The manikin is guaranteed against defects for 3 years from the date of purchase. This
guarantee covers the mechanical parts of the manikin only, the electronic components are
guaranteed for 2 years from the date of purchase. Consumable items are excluded from
this guarantee.
If making a claim, you must enclose a proof of purchase and details of where the manikin
was purchased. In the event that you are not able to supply a proof of purchase, or if it is
illegible, free after sales service may be restricted.
Also, in any of the following cases, after-sales service may be restricted.
- Damage or defect of the manikin due to abnormal use, user's negligence or mistake
- Damage or defect of the manikin due to repair of the manikin at a place other than the
company, authorized sales agency or service center or replacement of component with
other company's product which is not provided by us
- Damage or defect of the manikin due to it’s use or storage in unsuitable environments
such as in high temperature, high humidity, or where there is existence of chemical
compounds or microorganisms
- Damage or defect of the manikin due to natural disasters or acts of God such as re,
earthquake, ood and lightning and other events that are beyond the scope of the
company's control
- When information such as the date of purchase, customers name, name of supplier and
manufacture's serial number has been modied intentionally
- When there is no proof of purchase
Service center
Innosonian, Inc.
Homepage www.innosonian.com
Address 4F, 62, Bangbae-ro, Seocho-gu, Seoul, 06704, Republic of Korea
Tel +82 2-533-9410
Fax +82 70-8673-5285
Product purchase and service inquiry
Tel +82 70-4801-5378
E-mail [email protected]
This manikin observes the environmental requirements specied in EMC Guideline
2004/108/EC and EU Guideline RoHS 2011/65/EU for harmful substances.
Correct disposal of the batteries in this product
(Applicable in countries with separate collection systems)
This marking on battery, manual or packaging indicates that the batteries in this
product should not be disposed of with other household waste at the end of
their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that
the battery contains mercury, cadmium or lead above the reference levels in EC
Directive 2006/66. If batteries are not properly disposed of, these substances can
cause harm to human health or the environment.
To protect natural resources and to promote material reuse, please separate
batteries from other types of waste and recycle them through your local, free
battery return system.
Rev.3.0